I-GDYD-M AC Dielectric Test Equipment eneyunithi yokulawula eyenziwa ngesandla

I-GDYD-M AC Dielectric Test Equipment eneyunithi yokulawula eyenziwa ngesandla

Incazelo emfushane:

Izinhlelo zokusebenza ezijwayelekile zihlanganisa ukuhlolwa kwama-transformer, ama-switchgear, izintambo, ama-capacitor, izinkundla zamamotho asemoyeni, izitini zamabhakede zezinti ezishisayo, amabhodlela evacuum nezinye izinto ezihlobene ezifana neziphazamisi ze-vacuum, izingubo zokulala, izintambo, amagilavu, ipayipi lama-hydraulics, amajeneretha okuguqula izinsimbi.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Isicelo

Ukuhlolwa kwe-AC Hipot kuyindlela esebenzayo neqondile yokuhlola amandla okufaka izinto zikagesi, izinto zokusebenza, noma imishini.Ihlola amaphutha ayingozi aqinisekisa ukuthi imishini kagesi isebenza ngokuqhubekayo.Izinhlelo zokusebenza ezijwayelekile zihlanganisa ukuhlolwa kwama-transformer, ama-switchgear, izintambo, ama-capacitor, izinkundla zamamotho asemoyeni, izitini zamabhakede zezinti ezishisayo, amabhodlela evacuum nezinye izinto ezihlobene ezifana neziphazamisi ze-vacuum, izingubo zokulala, izintambo, amagilavu, ipayipi lama-hydraulics, amajeneretha okuguqula izinsimbi.

Izici

Iphaneli yokubonisa isibonisi izilawuli ezikhweziwe nezinkomba ezinenganekwane efundeka kalula.
Ukuqapha i-voltage yaseceleni ephezulu kagesi, i-voltage ephansi ohlangothini lwamanje kanye nenkomba kaziro, amandla, ukuqala kokusebenza, isikhathi.
Ukuvikelwa kwamanje, ukuvikela okungaqalisi iqanda, umsindo, ne-alamu ekhanyayo.
Ukukhishwa okuguquguqukayo okuqhubekayo ukusuka ku-zero kuye ku-voltage egcwele.
Ingalungiseka ngaphezu kokuvikela kwamanje, ngamaleveli ohambo ahluka ukusuka ku-10 kuye ku-110%.
Ngohlobo olusha lokudlulisa isikhathi, ibanga lesikhathi libanzi (1S ~ 99H).
Ukusebenzisa i-relay yakamuva, enembe kakhulu futhi enokwethenjelwa.
Isisindo esincane, usayizi omncane, kulula ukuhamba.

Imininingwane Yezobuchwepheshe

I-voltage yokufaka: AC 220V noma 380V
Iyunithi yokulawula yokuphumayo: AC 0-250V noma 0-430V
Okukhiphayo okwamanje kweyunithi yokulawula:0-5/10/15/50A(kwenziwe ngokwezifiso)
Amandla: 0-3/5/10/15/20/30/50/100kVA(ngokwezifiso)
Amandla okukhipha amandla eyunithi ye-HV: 0-50/100/150/200kV(eyenziwe ngokwezifiso)
Okukhiphayo okwamanje kweyunithi ye-HV: 0-50/100/150/200/500/1000/2000mA(kwenziwe ngokwezifiso)
Isikhathi: 0-9999s
Izinga lokushisa lemvelo: -20℃--50℃
Ukunemba kwamandla kagesi: ≤ 1.5%±1digit (FS)
Ukunemba kwamanje: ≤ 1.5%±1digit (FS)

Ezinye izesekeli zokuzikhethela

I-AC Digital Voltage Meter: 50,100,150, 200kV
I-Sphere Gap
Induku yokukhipha
Ukumelana namanzi noma isivikelo esiqinile sokuzivikela
I-HV filter capacitor: 0.01μF-0.1μF, 40-300kV

Singakwazi ukwenza ngokwezifiso izilinganiso ezihlukene ngokusekelwe ezimfuneko ezahlukene.Siyakwamukela ukubonisana nathi!