I-GD-4136H Uhlelo Lokuthola Iphutha Lekhebula
I-GD4136H Cable Fault system iyithuluzi elibalulekile lokugcina zonke izinhlobo zezintambo.Isebenzisa indlela ehlukahlukene yokuthola ukuhlola amaphutha ekhebula, efanele amazinga ahlukene amakhebuli kagesi kagesi kanye nezintambo zokuxhumana.
Uhlelo luqukethe amayunithi angezansi:
I-1.GD-2131H Impulse Generator
2.GD-4132 Indawo Yephutha Lekhebula
3.GD-4133 Multi-pulse Cable Fault Detector
I-4.GD-4133S I-Multi-pulse Coupler
5.Ezinye izesekeli
I-GD-2131H Impulse Generator
Isetshenziselwa ukukhiqiza umfutho we-HV uma usebenzisa indlela ye-flashover engaguquki ukuze kutholwe iphutha eliphezulu le-impedance.
●Amandla okuvutha aqinile, amandla amakhulu okushisa ngu-1000W, ukuwohlokaiphuzu lingashiswa ngesikhathi esifushane futhi ukumelana kwephuzu lokuqhekeka kuyancipha.
●Uma usebenzisana ne-GD-4133 Cable Fault Tester, kunezindlela ezimbili zokuthola indawo:
a.I-low voltage pulse: Uma kusetshenziswa i-GD-4133 kuphela, ikhebula elivulekile lesifunda kanye namaphutha okumisa ikhebula aphansi angatholakala, futhi ubude bekhebula bungalinganiswa noma kutholwe isivinini samagagasi sekhebula.
b.I-flashover ye-voltage ephezulu: I-wave wave ye-pulse voltage ekhiphayo yephoyinti lephutha isampula ngokukhipha igebe le-sphere, elingathola ibanga lephutha.
●Khiqiza umfutho wefrikhwensi engashintshi.Uma usebenzisana ne-GD-4132 Cable Fault Locator, kukhona imisebenzi elandelayo:
a.Imvamisa yomsindo: thola i-impedance ephezulu, amaphutha we-flash-over.
b.Ukuze ukhombe umzila wekhebula, khomba ikhebuli ekhethekile.
c.Ukuqhekeka kwe-metallic(isisekelo esifile), kusetshenziswa isilinganiso senkundla kazibuthe ukuze kutholwe ngokunembile.
●Ingasetshenziswa futhi ku-DC HV ukumelana nokuhlolwa.
●Okokufaka kwamandla: AC 220V, 50Hz
●I-voltage ephumayo: DC 0-32kV (iyalungiseka)
●Amandla alinganiselwe: 2kVA
●I-Max.energy: 2048J, 4uF
●I-DC flashover voltage: 32kV
●I-DC flashover yamanje: 63mA
●I-Max.impulse yamanje: 500mA
●Indlela yokukhipha: I-DC HV, isikhathi esisodwa, umjikelezo
●Isikhathi sokukhipha umjikelezo: imizuzwana engu-3-6
●Izinga lokushisa lemvelo: 0-40 ℃
●Ukuswakama:<75% RH
●Ukuphakama: <1000m
●Izinga le-insulation: A
●Ubukhulu: 430*540*410mm
●Isisindo: cishe 31kg.
Kubandakanya iyunithi eyinhloko, inzwa ye-acoustic nekazibuthe, i-headphone emelene nomsindo neshaja.
Kufanelekile ukuhlola zonke izinhlobo zekhebula lamandla nge-conductor yensimbi.
Umsebenzi wayo oyinhloko ukuthola indawo yokufaka engasebenzi kahle, ukuthola ukujikeleza nokujula kwekhebula lamandla.
●I-Acoustic Magnetic ithola ngesikhathi esifanayo.
●Ikhono eliqinile lokulwa nokuphazamiseka.
●Nge-headphone anti-nomsindo.
●320*240 LCD isibonisi sesikrini.
●Ibhethri ye-Li eyakhelwe ngaphakathi enomthamo omkhulu, eneshaja esheshayo.
●Isibonisi se-acoustic ne-Magnetic signal waveform, isignali nomsindo kulula ukuhlukanisa.
●Usebenzisa ikhesa ukulinganisa ukubambezeleka kwe-acoustic nokuzibuthe, thola ngokunembile iphuzu lephutha.
●Ngokuvumelana ne-polarity yokuqala ye-magnetic.waveform, ingathola futhi ithole umzila.
1. Indawo umsebenzi
a.Ibhendi yokudlulisa isignali ye-Acoustic: imvamisa yesikhungo esingu-400Hz, umkhawulokudonsa ongu-200Hz
b.Ukuzuza kwesignali: 80dB
c.Ukunemba kwendawo: 0.1m
2.Ukunikezwa kwamandla
a.Ibhethri ye-Li eyakhelwe ngaphakathi, amandla kagesi angu-7.4V, umthamo ongu-3000mAH.
b.Ukusetshenziswa kwamandla: 300mA, isikhathi sokusebenza esiqhubekayo 9hours.
c.Ishaja: okokufaka AC220V±10%, 50Hz.Okuphumayo okungajwayelekile okungu-8.4V, DC 1A
d.Isikhathi sokushaja: Amahora angu-4
3. Ubukhulu: 270mm*150mm*210mm
4. Isisindo: 1.5kg.
5. Sebenzisa isimo
Izinga lokushisa -10℃--40℃, umswakama 5-90%RH, ukuphakama <4500m
I-GD-4133 Cable Fault Detector isetshenziselwa ukukala
ibanga phakathi kwamaphutha ekhebula.Kulula ukwenza
isebenze futhi ine-interface enobungane.
Ingasetshenziswa yodwa ngaphansi kwemodi ye-low voltage pulse.U
ngaphansi kwemodi ye-pulse current, idinga ukusebenza ne-GD-2131
high voltage generator.Ngaphansi kwemodi ye-pulse eminingi, i-GD-4133S
I-coupler kufanele isetshenziswe ndawonye.Ngemuva kokutholwa kwebanga, isikhombisi sephutha se-GD-4132 kufanele sisetshenziselwe ukukhomba iphutha.Le mikhiqizo ingahlanganiswa ibe
isethi yokusebenza okuphezulu kanye nesistimu yokuhlola iphutha lekhebula.
●Isikrini se-LCD esingu-7inch, isikhombikubona esinobungane.
●Indlela yokubeka amabanga amaningi:
Indlela ye-low voltage pulse: ilungele ukutholwa kwephutha eliphansi lokumelana, iphutha lesifunda esifushane, iphutha lesekethe elivulekile.Ingasetshenziswa futhi esilinganisweni sobude bekhebula, amalunga amaphakathi, amalunga e-T, kanye nejoyinti yokunqanyulwa kwekhebula.Le ndlela futhi ingasetshenziswa ukulungisa isivinini samagagasi.
Indlela yamanje ye-Pulse: Ifanele ukukalwa kwebanga lephutha eliphezulu lokumelana, iphutha lokuphuka.Ukusebenzisa i-coupler yamanje ukuqoqa amasignali kusukela kuntambo yomhlaba, kwenza umsebenzisi abe kude ne-voltage ephezulu.Le ndlela iphephile futhi ithembekile.
I-pulse eminingi: indlela ethuthukisiwe yokukala ibanga.I-waveform kulula ukuyibona futhi ukunemba kuphezulu.
●200MHz isampula yesikhathi sangempela.Ubukhulu.Ukulungiswa kokulinganisa okungu-0.4m.Inendawo encane efile futhi ikhethekile kukhebuli emfushane kanye nekhebula eliseduze.
●Thinta isikrini bese ucindezela ukhiye wokusebenza
●Ikhophi ye-PIP (isithombe.isitoreji sesikhashana)
Kuzoba newindi elikhulu futhi amawindi amathathu okugcina esikhashana angabheka ama-waveform amathathu ndawonye.
●Isistimu yokusebenza eyakhelwe ngaphakathi
Ukuphathwa kwesoftware okukhethekile yokuthuthukisa isoftware, ukwenza isipele nokubuyisela.
●Umsebenzi wesikali
Indawo yokuqala, abathintwayo abangu-10, iphutha lekhebula elilodwa kanye nobude obubodwa obugcwele kungase kusethiwe.
Bonisa isikali nokuhlola i-waveform ndawonye
●Isitoreji se-Waveform nokuxhumana nekhompyutha.
Ukugcinwa kwangaphakathi kwama-waveforms.
Nge-USB, ukulanda noma ukulayisha idatha
Ukuxhumana ngekhompyutha
●Ukuphathwa kwamandla
Ukukhanya kwangemuva kuba buthaka uma kungekho ukusebenza emizuzwini emi-2 futhi kucime emizuzwini eyi-10 uma kungekho msebenzi.
Ibhethri le-Polymer Lithium-ion elakhelwe ngaphakathi.
Isikhathi sokusebenza singafika emahoreni ama-5 ngokusetshenziswa ngakunye.
Ikesi eliqinile, kulula ukulithwala.
Izindlela zokuthola indawo | Indlela ye-low voltage impulse Indlela yamanje ye-Ipulse Indlela yomfutho eminingi uma ifaniswe ne-GD-4133S |
Ubukhulu.Imvamisa yesampula | 200MHz |
Zuza ububanzi | 0-70dB |
I-voltage ephansi ye-impulse voltage | 30V |
Max.resolution | 0.4m |
Ubukhulu.Ithola ububanzi | 100km |
Indawo efile | 2m |
Ibhethri | Amabhethri e-nickel-metal hydride aphinde ashajwe, isikhathi sokubekezela amahora angaphezu kwama-5 |
Isixhumi esibonakalayo sokuxhumana | I-USB |
Ukunikezwa kwamandla kagesi | Okokufaka kwe-AC220V,50Hz,i-2A yamanje,shaja amahora angu-8 |
Dim. | 274×218×81mm |
Isisindo | 3.5kgs |
Izinga Lokushisa Lokusebenza | -10 ℃-40 ℃ |
Umswakama | 5-90%RH |
Ukuphakama | <4500m |
Isebenza ngokubambisana ne-GD-4133 Cable Fault Detector,isetshenziselwa ukuthola iphutha lokuvuza okuphezulu kwe-impedance, iphutha le-flashover,umhlaba we-impedance ophansi kanye nephutha lesifunda elivulekile lamakhebuli kagesi.
I-GD-4133S inikeze isignali yokuhlanganisa i-pulse ye-GD-4133 kanyeihlukanise nemishini yamandla kagesi aphezulu.
●Ukusebenzisa ubuchwepheshe obuthuthuke kakhulu bokulinganisa kwe-pulse kanye ne-pulse balance.I-waveform ebonisiwe kulula kakhulu ukuyibona.
●Ngokuvikeleka kwe-HV, isekethe yokulinganisa namandla omfutho kagesi aphezulu ahlukaniswa ngogesi.
●Izintambo ezilula, eziphephile futhi ezinokwethenjelwa.
●I-Pulse voltage: 300V (PP)
●I-voltage ye-impulse evumelekile: <35kV
●Amandla okufakwayo avumelekile: <2000J
●Okokufaka kwamandla: 220V AC, 50Hz
●Ubukhulu: 560*230*220mm
●Isisindo: 7kg.