I-GD2000H 10kV Insulation Resistance Tester
Le divayisi ingahlola ukumelana nokufakwa kwe-insulation (njenge-transformer, i-switchgear, i-lead, motor) yamamojula ahlukene ohlelweni olulodwa, ukufaka insulate nokulungisa izingxenye ezihlulekayo.
Kubalulekile ukuqinisekisa izinga lemikhiqizo kanye nokuvikeleka komuntu kanye nezinto zokusebenza ngesikhathi sokusebenza ngokuhlolwa kokushisa kokuhlola into yokuhlola phansi noma ukufakwa kwamakhondatha aseduze.
Ngaphambi kwamandla kusistimu, sebenzisa ukuhlolwa kwe-insulation ukuze uqinisekise ukuthi kuhle yini ukuthuthukisa ukusebenza kwesistimu.Ukuhlolwa kwe-insulation ukuthola izinkinga zenqubo yokukhiqiza kanye nenkinga yemishini engatholakali ngaphambi kokuthi kwenzeke ukwehluleka.E-EU, lokhu kuhlola kuyimpoqo, ngisho nasohlelweni lomphakathi.
1. I-Voltage ephumayo GD2000H (5kV/10kV).Ibanga lokumelana 0-400GΩ.
2. Izindlela ezimbili zibonisa ukumelana nokwahlukanisa.
3. Isilinganiso sokumunca esizibala kanye nenkomba ye-polarization.
4. Ukusebenza okunobungane, ukonga okuqhubekayo izikhathi eziyi-19 zokulinganisa imiphumela.
5. I-Auto-Discharge residual high voltage ngemva kokuphela kokuhlolwa.
6. Ukunikezwa kwamandla e-AC/DC, nebhethri elishajekayo noma i-adaptha ye-AC.
7. Ikhono eliqinile lokulwa nokuphazamiseka, ukufunda okuzinzile nokuthembekile.
8. Idizayini ephathekayo, ilungele umsebenzi wasendle.
9. I-Short-circuit current ≥3.5mA, imishini efanelekile yokuhlola ukumelana nokufakwa kwe-transformer enkulu, i-inductor, i-generator, i-HV motors, i-capacitor kagesi, izintambo kanye nesiboniso sokuhlinzwa.
IntoImodeli | GD2000H | ||
I-voltage yokuphumayo | 5kV DC | 10kV DC | |
Ukunemba | Izinga lokushisa | 23℃±5℃ | |
Ukumelana ne-insulation | 5M ~ 100G ±5% | 10M ~ 200G ±5% | |
Olunye ububanzi: ±10% | |||
I-voltage yokuphumayo | 40M ~ 200G 0 ~ +10% | 80M-400GΩ 0 --+10% | |
Si-hort-circuit current | ≥3.5mA | ||
Ukunikezwa kwamandla kagesi | 8*Uhlobo lwe-AA lomthamo omkhulu webhethri elishajekayo ne-adaptha yangaphandle | ||
Izinga Lokusebenza. & Nomswakama | -10℃--40℃,umswakama ophezulu.isihlobo 85% | ||
Izinga Lokushisa Lokugcina Nomswakama | -20℃--60℃,umswakama ophezulu.isihlobo 90% | ||
I-Insulation | I-Max.20000MΩ lapho i-voltage phakathi kwesekhethi negobolondo ingu-1000VDC. | ||
Melana ne-voltage | Ibekezelela i-1min uma i-voltage iphakathi kwesekethe negobolondo3kV /50HzAC | ||
Ubukhulu | 230mm*190mm*90mm (L*W*H) | ||
Isisindo | 3kg | ||
Izesekeli | Imikhondo yokuhlola, i-adaptha eshintshwayo, ikhebuli yamandla, umbiko wokuhlola |
Umhloli wokumelana ne-insulation | 1 isethi |
Intambo yokuhlola | 1 ucezu |
I-adaptha yamandla | 1 ucezu |
Intambo yamandla | 1 ucezu |
Umhlahlandlela Womsebenzisi | 1 ikhophi |
Isitifiketi | 1 ikhophi |