I-GD3127 Series High Voltage Insulation Resistance Tester
I-GD3127 Series Insulation Resistance Tester isetshenziswa kabanzi ekunakekelweni kwezinto zikagesi esiteshini se-transformer, isikhungo samandla, njll. Ifanele ukwenza ukukalwa kokumelana nokufakwa kwe-insulation(IR), inkomba ye-polarization(PI), isilinganiso sokumuncwa (DAR), irempu( I-RAMP), isihlungi(FR, 10s, 20s, 30s, 40s 4 choices), i-voltage(V), yamanje(nA) yazo zonke izinhlobo zemishini yamandla kagesi aphezulu, okuhlanganisa i-switchgear, ama-transformer, ama-reactors, ama-capacitor, izinjini, amajeneretha nezintambo, njll.
I-GD3127 Series iyithuluzi lokuhlola eliphelele lokuhlonza kusenesikhathi nokutholwa kwezinhlelo zokuvikela noma ezibikezelayo zokulungisa ukwehluleka okungenzeka kwemishini.Kubaluleke kakhulu ukuqinisekisa ikhwalithi yomkhiqizo nokuphepha kwabantu kanye nemishini yokusebenza.Ukusebenza kwe-insulation yemikhiqizo kagesi kungenye yezimpawu ezibalulekile zokuhlola ikhwalithi yokushisa, eboniswa ukuhlolwa kokumelana nokushisa.
●Ubukhulu.isikhashana esifushane > 5mA.
●Ukumelana ne-Insulation (IR), inkomba ye-polarization (PI), isilinganiso sokumunca (DAR).
●Irempu(RAMP), isihlungi(FR), i-voltage(V).
●Qapha ngokuzenzakalela i-voltage ephilayo yento elinganisiwe, futhi uvimbele ngokuzenzakalelayo ukuhlolwa uma i-voltage idlula u-36V, okuvikela ngempumelelo ithuluzi nomsebenzisi.
●Umsebenzi wesikhathi, rekhoda ngokuzenzakalelayo isikhathi sokuhlola.
●Khipha ngokuzenzakalelayo i-voltage ephezulu ngemuva kokuqedwa kokulinganisa, isikhathi sokukhipha asidluli imizuzwana engama-30.
●Umsebenzi wokucisha amandla okuzenzakalelayo.
●Isibonisi esikhulu samachashazi esikrini se-LCD esisebenza ngokuzinzile.
●Ukwakheka kwegobolondo elendlalelo ezimbili, liqinile futhi liqinile, izinga lokuvikela i-IP65.
●Iphakethe elikhulu lebhethri le-lithium elishajwayo.
●Umsebenzi wesitoreji, ungagcina ngokuzenzakalelayo amasethi ayi-1000 edatha yokuhlola yesikhathi sangempela nedethi yokuhlola nesikhathi nesikhathi sokuhlola.
●Layisha umsebenzi, ifakwe USB interface, irekhodi idatha ingalayishwa kukhompyutha ukuze kuhlaziywe izibalo idatha.
Umsebenzi | Ukumelana ne-insulation(IR), inkomba ye-polarization(PI), isilinganiso sokumunca (DAR), irempu(RAMP), isihlungi(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) |
Ukunikezwa kwamandla kagesi | Iyashajwa kabushaibhethri ye-lithium5.2Ah |
I-voltage elinganiselwe | I-GD3127: 250V, 500V, 1kV, 2.5kV, 5kV I-GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
I-voltage ephumayo aukunemba | (5%-10%)±10V |
Ibanga lokulinganisa ukumelana ne-insulation | I-GD3127:0.50MΩ~2.00TΩ I-GD3127B: 0.50MΩ~5.00TΩ |
Isifunda esifushane samanje | > 5mA |
Inkomba ye-Polarization(PI) | Yebo |
I-Absorption ratio (DAR) | Yebo |
Imodi yokuhlola ye-Ramp(RAMP). | Hlola ngezinyathelo ezingu-10% we-voltage esethiwe kuze kufike i-voltage esethiwe |
Imodi yokuhlola yokuhlunga | Izinketho ezine ze-10S, 20S, 30S, 40S |
Ukuhlolwa kwe-voltage | Ibanga: AC/DC 0V-1000V, ukunemba:±5%rdg±3V |
Ukuhlolwa kwamanje | Ibanga: 0.01nA-7mA, ukunemba:±5%rdg±0.5nA |
I-voltage monitor | Gada i-voltage yento ehloliwe, qapha isimo sokuphuma ngemva kokuhlolwa, futhi uvimbele ukuhlolwa lapho i-voltage inkulu kuno-36V, vikela ithuluzi nomsebenzisi. |
Hlola isibali sikhathi | Rekhoda ngokuzenzakalelayo isikhathi sokuhlola, ibanga lesikhathi: 0s~9999s |
Isitoreji | Ukugcinwa okuzenzakalelayo kwedatha yokuhlola enedethi nesikhathi, isamba samaqembu angu-1000 |
Ukuxhumana | Layisha idatha yokuhlola egciniwe kukhompuyutha ngomugqa wokuxhumana we-USB. |
Ibhethri | Kukhona isibonisi sezinga lebhethri, esikhumbuza ukushaja ngesikhathi lapho umthamo webhethri uphansi |
Umsebenzi wokucisha amandla ngokuzenzakalelayo | Ukucisha okuzenzakalelayo ngemva kwemizuzu engu-15 |
Isigaba sokuvikela | IP65/IP40 |
Ukumelana ne-insulation | 50MΩ(1000V) (phakathi komjikelezo wokuhlola negobolondo) |
Melana ne-voltage | I-AC 3kV 50Hz 1min (phakathi komjikelezo wokuhlola kanye negobolondo) |
Amazinga | I-IEC61010-1, IEC61326-1 |
Izinga lokushisa lokusebenza kanye nomswakama | - 20℃ ~ +50℃ <80%RH |
Izinga lokushisa lesitoreji nomswakama | - 25℃ ~ +65℃80%RH |
Ukunikezwa kwamandla kagesi | 220V AC 50Hz |
Ubukhulu (mm) | 280(L)*260(W)*160(H) |
Isisindo | 4400g(faka ibhethri) |
Umhloli wokumelana ne-insulation | 1 isethi |
Intambo yokuhlola i-voltage ephezulu (Bomvu) | 1 ucezu |
Intambo yokuhlola(Luhlaza) | 1 ucezu |
Isivivinyoucingo(Mnyama) | 1 ucezu |
I-adaptha yamandla | 1 piece |
Umsebenzisi's umhlahlandlela | 1 ikhophi |
Isivivinyori-eport | 1 ikhophi |