I-GD6900 Capacitance and Dissipation Factor Tester
I-GD6900 ikala amandla kanye ne-dielectric loss factor (tgδ) yamathuluzi kagesi anamandla aphezulu.Isakhiwo esihlanganisiwe, ibhuloho lokuhlola ukulahlekelwa kwe-dielectric eyakhelwe ngaphakathi, ukunikezwa kwamandla okuguquguqukayo okuguquguqukayo, i-boosting transformer kanye ne-SF6 standard capacitor.
Umthombo wamandla kagesi aphezulu ukhiqizwa i-inverter yangaphakathi yensimbi, esetshenziselwa ukuhlola into yokuhlola ngemva kokuthuthukiswa kwe-transformer.Uma wengeza inkomishi yokufaka inkomishi kanye nedivayisi yokulawula izinga lokushisa, ukulahlekelwa kwe-dielectric kawoyela ovikelayo kungahlolwa.
●Thinta isibonisi sesikrini se-LCD.
●Isilinganiso sokumelana nokufakwa kwe-insulation: Imojula yokuhlola yokumelana nokufakwa ngaphakathi eyakhelwe ngaphakathi, ingenza i-Insulation resistance (IR), i-absorption ratio (DAR), ukuhlolwa kwe-polarization index (PI).
●I-chip yekhalenda nesitoreji esikhulu ngaphakathi.Londoloza umphumela wokuhlola ngokuya nge-oda lesikhathi, hlola irekhodi lomlando bese uphrinte umphumela.
●Idatha yensimbi ingathunyelwa nge-U disk.
●Imodi yokuhlola eminingi, enezindlela zangaphakathi zamandla kagesi aphezulu, ngaphandle kwamandla kagesi aphezulu, indinganiso yangaphakathi, indinganiso yangaphandle, i-GST/UST, ukuzithokozisa.Ukuhlolwa kokulahlekelwa kwe-dielectric ephezulu (ngaphezu kuka-10kV) kungenziwa esimweni sezinga langaphandle ngaphandle kwamandla kagesi aphezulu.
●Hlola i-CVT evaliwe egcwele (I-Capacitive Voltage Transformer) i-C1 ne-C2 ukulahleka kwe-dielectric namandla ngesikhathi esifanayo.Futhi hlola isilinganiso sokuguqulwa kwe-CVT kanye nomehluko we-engeli ye-voltage.
●Ukulahleka kwe-dielectric kanye nevelu ye-capacitance ye-C0 engxenyeni engenhla ye-CVT ingalinganiswa ngokusebenzisa indlela yokuvikela ehlehlayo.
●Isignali yesampula yesivinini esiphezulu.I-inverter kanye nesekethe yamasampula ngaphakathi kulawulwa idijithali.I-voltage ephumayo ilungiswa ngokuqhubekayo.
●Isilinganiso esizenzakalelayo se-LCR.I-inductance, i-capacitance, ukumelana, i-engeli ingalinganiswa futhi iboniswe.
●Ukuvikelwa okuningi kokuguquguquka kwe-voltage yokufaka, isifunda esifushane esiphumayo, i-over-voltage, over-current, izinga lokushisa, ivikelekile futhi inokwethenjelwa.Khonamanjalo, inomsebenzi wokuhlola ukubeka phansi, lokho kukhushulwa kwamandla kagesi akuvunyelwe emishinini engagxili.
●Asikho isidingo sokuqaqa umthofu we-HV ukukala ukulahleka kwe-dielectric namandla e-CVT.
●Imvamisa ingashintshwa ibe ngu-50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Isimo sokusebenza | -15 ℃ ~ 40 ℃ | RH<80% | ||||||
Isimiso sokulwa nokugxambukela | Ukuguqulwa kwemvamisa | |||||||
Ukunikezwa kwamandla kagesi | I-AC 220V±10%, 50/60Hz | Ijeneretha ingasetshenziswa. | ||||||
Okukhipha amandla kagesi aphezulu | I-AC 0.5KV~10KV (12kV ngokuzithandela) | Njalo ngo-0.1kV | ||||||
Ukunemba | 2% | |||||||
Ubukhulu.okwamanje | 200mA | |||||||
Amandla | 2000VA | |||||||
Amandla okuzithokozisa | I-AC 0V~50V/15A | 50Hz, 60Hz imvamisa eyodwa 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Imvamisa ekabili ezenzakalelayo | ||||||
Isixazululo | I-tgδ: 0.001% | Cx: 0.001pF | ||||||
Ukunemba | ∆tgδ: ±(ukufunda*1.0%+0.040%) | |||||||
∆C x: ±(ukufunda*1.0%+1.00PF) | ||||||||
Ibanga lokulinganisa | tgδ | Ngaphandle komkhawulo | ||||||
C x | 15pF < Cx <300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
Ukuhlolwa kwe-CVT | Cx <300 nF | |||||||
Ibanga lokulinganisa le-LCR | L>20H(2kV) | R>10KΩ(2kV) | ||||||
Ukunemba kwesilinganiso se-LCR | 0.1% | Isixazululo | 0.01 | |||||
Ibanga lesilinganiso se-CVT | 10 ~ 10000 | |||||||
Ukunemba kwesilinganiso se-CVT | 0.1% | |||||||
Ukulungiswa kwesilinganiso se-CVT | 0.01 | |||||||
Ukumelana ne-insulation | I-DC high voltage | 5 ~ 10kV | Ukunemba | ±(2%*Ukufunda +10V) | ||||
Ukunemba kwe-IR | 100kΩ-1000GΩ: <5% (i-voltage yokuhlola engekho ngaphansi kuka-250V) I-100GΩ-1000GΩ: 10% (i-voltage yokuhlola engekho ngaphansi kuka-10000V) | |||||||
Ubukhulu | Iyunithi eyinhloko: 350(L)×270(W)×270(H) | |||||||
Ibhokisi lesesekeli: 350(L)×270(W)×160(H) | ||||||||
Amandla enkumbulo | Amaqembu angama-200, isitoreji se-USB flash disk siyasekelwa. | |||||||
Isisindo | Iyunithi eyinhloko: 22.75Kg | |||||||
Ibhokisi lesesekeli: 5.25Kg |
Umhloli | 1 isethi |
Ikesi lezesekeli | 1 isiqephu |
I-HV ebomvu ihola i-8m | 1 isiqephu |
I-LV emnyama ihola i-8m | 1 isiqephu |
Intambo yamandla 1.8m | 1 isiqephu |
I-CVT Connecting lead 5m | 1 isiqephu |
Ukuhamba phansi 2m | 1 isiqephu |
Iphepha lokuphrinta | 2 imiqulu |
10A fuse | 3 izingcezu |
Umhlahlandlela Womsebenzisi | 1 ikhophi |
Umbiko Wokuhlolwa Kwemboni | 1 ikhophi |
Izesekeli ozikhethela | |
Uwoyela Test cell | 1 pc |
Isilawuli sokushisa | 1 pc |
Ngeseli yokuhlola uwoyela nesilawuli sokushisisa, umsebenzisi angahlola i-tan delta yoketshezi lwe-dielectric njengowoyela we-transformer.
Isilawuli sokushisa
Isitsha sikawoyela