I-GDB-H Handheld Automatic Transformer Ijika Isihloli Sesilinganiso
I-GDB-H iyidivayisi ephathwa ngesandla.Ingakwazi ukukala ngokunembile isilinganiso sokuphenduka, i-engeli yeqembu kanye nesigaba, elungele zonke izinhlobo zama-transformer afana neziguquli zohlobo luka-Z, ama-rectifier rectifier, ama-electric furnace transformer, ama-phase-shifting transformer, ama-traction transformer, ama-scott nama-invert-scott transformer.
●5.6inch TFT umbala LCD screen, intuitively sibonisa idatha kanye vector idayagramu.
●ukuhlolwa kwezigaba ezi-3 ngesikhathi esifanayo.Okokufaka kwamandla esigaba esisodwa, nenhlanganisela yangaphakathi yedijithali umthombo wokuhlola ojwayelekile we-sine wave.Ikhiqiza amandla okuhlola ezigaba ezi-3 (idigri yokuhlanekezela ingaphansi kuka-0.1%, idigri yokulinganisa ingcono kuno-0.05%) nge-Hi-fi power amplifier.Imiphumela yokuhlolwa inokulingana okungcono, futhi ngeke kubonakale ukungahluleli kahle kwezifunda.
●Kokubili ukulinganisa kwesigaba esisodwa kanye nokuhlola okuzenzakalelayo kwesigaba esingu-3.Ingakwazi ukukala i-polarity ne-engeli yesigaba ngaphansi kwesigaba esisodwa noma ukuhlolwa kwesigaba esingu-3.Ngesikhathi esisodwa qedela isilinganiso sokuphenduka kwesilinganiso, inani le-engeli yesigaba, iphutha, indawo yokuthepha, inani lokuthepha elingu-AB, BC, CA.Inombolo yeqembu ingabonakala ngokuzenzakalelayo.
●Imisebenzi yokulinganisa i-engeli yesigaba.Linganisa ngokunembile i-engeli yesigaba phakathi kwe-voltage ephezulu ne-low voltage.Ingakwazi futhi ukukala isilinganiso sokuphenduka kanye ne-engeli yama-transformer “amaphuzu angeyona ingxenye ebalulekile”.
●Imiphumela yokuhlolwa iboniswa nge-figure kanye ne-hexagonal vector, ikhombisa ngokuqondile iqembu lokuxhuma i-transformer.
●Asikho isidingo sokukhetha indlela yokuxhuma noma iqembu lokuxhuma, lingalinganisa i-Y/△, △/Y isiguquli ngaphandle kokuxhumeka okufushane kwangaphandle.Futhi ingashintsha izindlela zokuxhuma ngokuya ngezinto zokuhlola ezikhethiwe.I-Transformer ngaphandle kwe-nameplate ingalinganiswa.
●Kala ngokushesha isilinganiso sokuphenduka kanye nephutha lesilinganiso sendawo ngayinye yokushintsha kampompi.Isilinganiso sokufakwayo esikalwe kuphela ngesikhathi esisodwa, asikho isidingo sokufaka okuphindaphindiwe ukuze ubale iphutha lesilinganiso sokuma kokuthepha ngakunye.
●Ngemisebenzi yakho kokubili ukuphenduka kwesilinganiso sesilinganiso kanye nesilinganiso se-voltage yokusebenza.Isilinganiso sokusebenza singabonisa ngempela inani langempela le-voltage ratio ngesikhathi sokusebenza.
●Ngokumelana okuhle nokudlidliza.
●Umthombo wokuhlola waleli thuluzi umthombo wegagasi ojwayelekile we-sine synthesis wedijithali.Idigri yokuhlanekezela ingaphansi kuka-0.1%, ayithinteki ngekhwalithi yokuphakelwa kwamandla.
●Usayizi omncane, isisindo esincane, kulula ukuthwala.
●Ibhethri le-Lithium-ion elakhelwe ngaphakathi elikwazi ukushajwa kabusha.Ukuhlolwa kungaqedwa ngaphandle kwamandla.Ukushaja okugcwele kwesikhathi esisodwa kuthatha isilinganiso esiqhubekayo esingaphezu kwezikhathi ezingu-800.
●Idatha yokulinganisa indawo ingagcinwa, futhi umphumela ungadluliselwa ku-PC nge-U disk.
●Ibanga lokulinganisa le-TTR: 0.8 ~ 10000.
●Isivinini sokulinganisa esisheshayo: ukuhlolwa kwezigaba ezintathu kungaqedwa phakathi kwamasekhondi angu-60.
●Ukunemba kokulinganisa:
Ukunemba kwesilinganiso samandla kagesi ohlangothini lwe-HV: 0.05%
Ukunemba kwesilinganiso samandla kagesi ohlangothini lwe-LV: 0.1%
Ukunemba kwesilinganiso se-engeli yesigaba: 0.1°
Ukunemba kwesilinganiso se-TTR: 0.1% (0.8-3000)
0.2% (3000-10000)
●Isisindo: mayelana ne-3Kg.
Insimbi ye-GDB-H | 1pc |
Ikesi lesesekeli | 1pc |
I-HV Test lead ene-clamp | 1 isethi |
I-LV Test lead ene-clamp | 1 isethi |
I-Fuse | 2 ama-pcs |
Ishaja | 1pc |
Igayidi yomsebenzisi | 1pc |
Umbiko wokuhlolwa kwefekthri | 1pc |