I-GDBR-P Transformer Load No-load and Capacity Tester
●Linganisa i-transformer No-load current, ukulahleka kwe-No-load, i-voltage yesifunda esifushane, ukulahleka kwesifunda esifushane kanye nomthamo.
●Izindlela zokuhlola amamitha amathathu.
●Lapho wenza i-transformer yesigaba sesithathu No-load, ukuhlolwa komthwalo, ithuluzi lizokwahlulela uma i-wiring ilungile ngokuzenzakalelayo, futhi ikhombisa i-voltage yezigaba ezintathu, umdwebo we-vector wamanje.
●Qedela ukuhlolwa komthwalo ngaphansi kuka-1600kVA ngezansi kwesiguquli sokusabalalisa esigcwele okwamanje kumshini owodwa.Qedela u-2500kVA ngezansi kokuhlolwa komthwalo wesiguquli sokusabalalisa ngaphansi kwe-1/3 yamanje elinganiselwe (Ngaphansi kwe-1/3 elinganiselwe yamanje, ithuluzi lingaguqulelwa ukuze lilayishe amapharamitha wokulahlekelwa ngaphansi kwesilinganiso samanje.)
●Yonke imiphumela yokuhlolwa ilungiswa ngokuzenzakalelayo.Ukulungisa okuzenzakalelayo kwethuluzi ngale ndlela elandelayo, ukulungisa i-waveform, ukulungiswa kwezinga lokushisa, Ukulungiswa kwe-voltage okungalinganiselwe kanye nokulungiswa kwamanje okungalinganiselwe.Imiphumela yokuhlolwa inembe kakhulu.
●320*240 isikrini se-LCD sokukhanya okuphezulu, esinokulungiswa kokukhanya.Izinkinobho zokuthintwa zenza umsebenzi ube lula.
●Iwashi lesikhathi sangempela, idethi yokuhlola yokurekhoda ngokuzenzakalelayo, ilungele ukugcinwa nokuphathwa kwemiphumela yokuhlolwa.
●Iphrinta yohlobo lwephaneli eyakhelwe ngaphakathi, imiphumela yokuhlolwa kokuphrinta okusheshayo.
●Yehlisa isitolo bese uphequlula idatha (isethi yento yokuhlola, imiphumela yokulinganisa, isikhathi sokuhlola) imisebenzi.Gcina kuze kufike ku-500groups imiphumela yokuhlolwa, ukudluliswa kwedatha ku-inthanethi ku-PC.
●Ivumela ukulinganisa okunwetshiwe kobubanzi be-voltage yangaphandle yesiguquli kanye ne-transformer yamanje.Linganisa into yokuhlola yanoma yimaphi amapharamitha.
1. Izinto zokuhlola
●I-RMS yezigaba ezintathu zamandla kagesi: Uab, Ubc, Uca.
●Isilinganiso senani le-voltage ye-AC yezigaba ezintathu: Uab, Ubc, Uca.
●I-RMS yezigaba ezintathu zamanje: Ia, Ib, Ic.
●Iphesenti Lokulahleka Komthwalo kanye Nomthwalo Wamanje: Po, Io%.
●Ukulahleka komthwalo, iphesenti le-impedance voltage, impedance yesifunda esifushane: Pt, ekt, Zt.
●Ukulahleka komthwalo, iphesenti le-impedance voltage kanye ne-impedance yesifunda esifushane kunoma yiliphi izinga lokushisa elicacisiwe.
●Umthamo wangempela we-Transformer namandla ahlulelwe.
2. Imingcele yezobuchwepheshe eyinhloko
●Ibanga lamanje lesilinganiso: 100mA-60A,ukunemba:isigaba 0.2.
●Ibanga lesilinganiso samandla kagesi: 10V-650V, ukunemba: isigaba 0.2.
●I-transformer yangaphandle inganweba ububanzi bokulinganisa bensimbi.
●Ibanga lokulinganisa imvamisa: 40-65Hz, ukunemba:isigaba 0.2.
●Okokufaka kwamandla: AC220V± 10%.
Iyunithi Eyinhloko | 1 pc |
Intambo yamandla | 1 pc |
Ikhebuli yokuhlola i-clamp | 1 isethi |
Ikhebula elikhethekile le-short-circuit | 1 pc |
Igayidi yomsebenzisi | 1 pc |
Umbiko wokuhlolwa kwefekthri | 1 pc |