I-GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer
I-GDC-9560B I-Gas Chromatograph Analyzer iwukuhlaziya okuqukethwe kwegesi kawoyela ohlukanisayo ngendlela ye-gas chromatographic.Kusebenza ngempumelelo ukwahlulela uma okokusebenza okusebenzayo kunephutha elingaba khona njengokushisa ngokweqile, ukukhipha noma cha, ukuze kuqinisekiswe ukuphepha kwegridi yamandla.Kuyadingeka futhi ukuthi kusetshenziselwe umkhiqizi wempahla yegesi/uwoyela ukuhlola okokusebenza kwabo ngaphambi kokuphuma efekthri.
Ubuchwepheshe bokuhlaziya i-chromatography yegesi buyindlela yokuhlukanisa nokuhlaziya izingxube zezingxenye eziningi.Ngokuyinhloko isebenzisa umehluko wephoyinti elibilayo, i-polarity ne-adsorption coefficient yengxenye ngayinye kusampula kukholomu, ukuze izingxenye zihlukaniswe kukholomu, futhi izingxenye ezihlukanisiwe zihlaziywe ngekhwalithi nangobuningi.
I-chromatograph yegesi isebenzisa igesi njengesigaba seselula (igesi yenkampani yenethiwekhi).Uma isampula ithunyelwa kumjovo futhi ifakwe umhwamuko, ithwalwa igesi yenkampani yenethiwekhi iye kukholomu epakishiwe noma ikholomu ye-capillary ngenxa yephoyinti elibilayo, i-polarity kanye ne-adsorption coefficient yengxenye ngayinye kusampula.Umehluko wukuthi izingxenye zihlukaniswa kukholomu, bese kuthi izitholi ezixhunywe kukholomu zitholwa ngokulandelana ngokuya nezici ze-physicochemical zezingxenye, futhi ekugcineni amasiginali kagesi aguquliwe athunyelwa endaweni yokusebenza ye-chromatographic.I-chromatogram yegesi yengxenye ngayinye iyarekhodwa futhi ihlaziywe ngendawo yokusebenza ye-chromatographic ukuze kutholwe imiphumela yokuhlaziya yengxenye ngayinye.
●Yamukela isixhumi esibonakalayo esithuthukisiwe se-Ethernet ye-10/100M kanye nesitaki sephrothokholi ye-IP eyakhelwe ngaphakathi, esenza ithuluzi libone kalula ukudluliswa kwedatha yebanga elide nge-LAN yangaphakathi ne-inthanethi.Isiza ukusethwa kwelabhorethri futhi yenza ilabhorethri ibe lula.Ukucushwa kusiza ukuphathwa kwedatha yokuhlaziya.
●Idizayini yezinqubo ezi-3 zokuxhuma ezizimele.Ingaxhunywa nokucubungula kwendawo (ilabhorethri), elula kakhulu kubaphathi ukuqapha isimo sokusebenza nokuhlaziya imiphumela.
●Isiteshi sokusebenzela se-NetChromTM esizikhethela sona singasekela ngesikhathi esisodwa ama-chromatograph amaningi ukuze kucutshungulwe futhi kulawulwe idatha, kwenze kube lula ukuphathwa kwemibhalo kanye nokunciphisa ukutshalwa kwezimali ngelebhu yomsebenzisi kanye nezindleko zokusebenza.
●Uhlelo ngesiNgisi nesiShayina, olungashintshwa ngokukhululekile.
●Indawo yokulawula izinga lokushisa ingaqanjwa ngokukhululekile ngumsebenzisi, okulungele abasebenzisi.
●Ukusebenzisa imodi yokusebenza ehambisanayo ye-multiprocessor, ezinzile futhi enokwethenjelwa.Ihlangabezana nokuhlaziywa kwesampula eyinkimbinkimbi.Ifakwe izinhlobonhlobo zezitholi ezisebenza kahle njenge-FID, TCD, ECD, ne-FPD.Kungafakwa ukuhlola kufikela kokune ngesikhathi esisodwa.Kuyenzeka futhi usebenzise indlela yokwengeza umtshina, elungele ukuthenga nokufaka amanye ama-detector ngemva kokuthengwa kwensimbi.
●Ithuluzi lamukela ukwakheka kwe-modular, eklanywe futhi yashintshwa, kulula ukuyithuthukisa futhi ivikele ukusebenza kahle kokutshalwa kwezimali.
●Uhlelo olusha lokulawula izinga lokushisa le-microcomputer linembayo yokulawula izinga lokushisa eliphezulu kanye nokuthembeka okuphakeme nokusebenza kokumelana nokuphazamiseka.Inezinhlelo eziyisithupha ezizimele ngokuphelele zokulawula izinga lokushisa, ezikwazi ukubona ukuhlelwa kwezinga lokushisa okuyizinyathelo eziyi-16, okwenza okokusebenza kube namandla okuhlaziya isampula.Inesistimu yokuvula isicabha sangemuva esizenzakalelayo kuhhavini, ethuthukisa ukunemba kokulawula izinga lokushisa eliphansi futhi inyuse ijubane lokukhuphuka/lokwehlisa.
●Ithuluzi lingahlonyiswa ngesilawuli sokugeleza kwe-elekthronikhi esithuthukisiwe (i-EFC) kanye nesilawuli sengcindezi ye-elekthronikhi (EPC) ukuze sibone ukulawula kwedijithali, okungathuthukisa kakhulu ukukhiqizwa kabusha kwemiphumela yekhwalithi nenani.
●Uhlelo lokuziqalisa lomklamo wesikhathi lungaqedela kalula ukuhlaziya okuku-inthanethi kwamasampula egesi (kudinga izingxenye zokujova ezizenzakalelayo eziku-inthanethi).
●Uhlelo lokusebenza lwekhibhodi yonke yokulawula i-microcomputer ilula futhi kulula ukuyisebenzisa;kanye nobuchwepheshe bokuhlonza obuzenzakalelayo bomtshina buklanywe.Ngokuxilongwa kwephutha nokuvikelwa kwedatha kokucisha amandla, amapharamitha angenziwa ngekhanda ngokuzenzakalela.
●Ithuluzi linomsindo ophansi owakhelwe ngaphakathi, isekethe ye-AD engu-24-bit enokulungiswa okuphezulu nokugcinwa kwesisekelo kanye nokususa okuyisisekelo.
●Qoqa amasignali e-chromatographic nokucubungula idatha, afanele i-WinXP, Win2000, Windows7 nezinye izinhlelo zokusebenza.Idatha eyisampula ifundwa kumafayela e-CDF ahlangabezana nezindinganiso ze-A/A (American Analytical Society), ngakho ingasetshenziswa ne-Agilent, Waters nezinye iziteshi zokusebenza ze-chromatography.
●Isistimu yeChromatographic enamalungelo empahla yobuhlakani ezimele ngokuphelele, enokusebenzelana okujwayelekile kwe-MODBUS/TCP, ingadokhwa kalula nge-DCS.
●Ithuluzi lingaxhunyaniswa nesampula yemoto ekhiqizwe abakhiqizi abaningi basekhaya nabangaphandle;njenge-Shimadzu AOC-20i, uchungechunge lwe-HT lwenkampani ye-HTA olusebenza kahle kakhulu, isampula yemoto yegesi.
Amagesi okubona | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 amagesi),O2(uma uthanda), i-N2 (uma uthanda) |
Display | 192*64 dot matrix LCD |
Indawo yokulawula izinga lokushisa | 6 izindlela |
Ibanga lokulawula izinga lokushisa | izinga lokushisa +5℃~400℃, ukwanda 1℃, ukunemba:±0.1℃ |
Uhlelo lokuhlela | 16 izinyathelo |
Izinga lokukhuphuka kohlelo | 0.1~40℃/min |
Ukulawula igesi | imodi yokulawula i-valve engumshini, imodi yokulawula ukugeleza kwengcindezi ye-elekthronikhi ngokuzikhethela |
Imicimbi yangaphandle | 4 amashaneli |
Uhlobo lomjovo | ikholomu epakishiwe, i-capillary, umjovo wegesi wevalvu wezindlela eziyisithupha, umjovo we-headspace ozenzakalelayo, njll. |
Inombolo yezithonjana | ama-4 ama-pcs;I-FID, TCD, ECD, FPD (kuyakhetheka) |
Qala umjovo | manual, othomathikhi ozikhethela |
Isixhumi esibonakalayo sokuxhumana | I-Ethernet: IEEE802.3 |
Imininingwane Yomtshina | |
Umtshina we-Hydrogen flame ionization (FID) | |
Umkhawulo wokutholwa | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Umsindo oyisisekelo | ≤ 5 × 10-14A |
I-Baseline drift | ≤ 1 × 10-13A / 30min |
Ububanzi bomugqa | ≥106 |
I-Thermal Conductivity Detector (TCD) | |
Ukuzwela | S≥2500mV•ml/mg (benzene/toluene) (ikhuliswe 1, 2, 4, 8 izikhathi ngokuzithandela) |
Umsindo oyisisekelo | ≤20μV |
I-Baseline drift | ≤30μV/30min |
Ububanzi bomugqa | ≥104 |
I-Electronic Capture detector (ECD) ngokuzikhethela | |
Umkhawulo wokutholwa | ≤ 1 × 10-13g/ml (propylene hexa-6 / isooctane) |
Umsindo oyisisekelo | ≤0.03mV |
I-Baseline drift | ≤0.2mV/30min |
Ububanzi bomugqa | 103 |
Umthombo we-radioactive | 63Ni |
Umtshina wesithombe somlilo (i-FPD) ngokuzikhethela | |
Umkhawulo wokutholwa | (S) ≤ 5×10-11g/s, (P) ≤ 1×10-12g/s;i-methyl parathion/ i-ethanol ephelele) |
Umsindo oyisisekelo | ≤ 3 × 10-13A |
I-Baseline drift | ≤ 2 × 10-12A / 30min |
Ububanzi bomugqa | Fnoma isulfure ≥ 102, okwe-phosphorus ≥ 103 |
I-Gas Chromatograph Main Unit | 1 isethi |
Ijeneretha ye-hydrogen | 1 isethi |
Ijeneretha yomoya | 1 isethi |
I-Multifunction Shaker | 1 isethi |
I-Valve Ejwayelekile Yokunciphisa Ukucindezela | 1 isethi |
I-Nitrogen Pressure Reducing Valve | 1 isethi |
I-nitrogen Cylinder | 1 ibhodlela |
Igesi ejwayelekile | 1 ibhodlela |
Indlela yegesi i-M8X1Φ3.2 | 10 ama-pcs |
I-valve yokunciphisa ingcindezi | 5 ama-pcs |
I-Capillary column nut Φ0.8 | 4 ama-pcs |
Ikholomu nati Φ4.2 kanye Φ3.2 | Ngamunye 5 ama-pcs |
Ipayipi legesi yensimbi engagqwali Φ2 | 10 ama-pcs |
Iphedi yokuvala indlela yegesi | 50 ama-pcs |
I-capillary sampler evaporative pad | 50 ama-pcs |
Iphedi ye-capillary graphite Φ0.8 | 20 ama-pcs |
Iphedi yegraphite Φ4.2 kanye ne-Φ3.2 | Ngamunye 10 pcs |
I-Fuse | 4 ama-pcs |
Isikulufa se-M3X5 | 6 ama-pcs |
Ipayipi legesi le-PE Φ3 | 20m |
1 ml umjovo wepulasitiki | 5 ama-pcs |
100 ml umjovo | 5 ama-pcs |
Inaliti | 10 ama-pcs |
20ml ingilazi injector | 5 ama-pcs |
5ml ingilazi injector | 5 ama-pcs |
I-injector yengilazi engu-1 ml | 5 ama-pcs |
Isiqeshana sobuningi | 2 ama-pcs |
I-Vaseline - 30 g | 2 ama-pcs |
I-screwdriver efakwe 50mm 70mm | I-1 pc ngayinye |
I-Crosshead screwdriver 50mm 70mm | I-1 pc ngayinye |
I-Wrench 8-10 | 1 pc |
I-Wrench 12-14 | 2 pc |
Iphinifa lekhala elicijile | 1 pc |
Ikhebula eliphansi | 1 pc |
Ikhebula lesiginali | 1 pc |
Intambo yamandla | 1 pc |
Ikepisi yerabha | 20 pc |
Isikhwama se-aluminium foil | 2 ama-pcs |
Inalithi ephindwe kabili | 25 ama-pcs |
Idiski | 1 pc |
Ikhebula lokuxhumana | 1 pc |
Ibhulokhi yegesi | 1 pc |