I-GDDO-20C AC/DC Idivayisi Yokulinganisa Imitha kagesi
I-GDDO-20C AC/DC Idivayisi Yokulinganisa Imitha kagesi isetshenziselwa ukuthola iphutha eliyisisekelo lamathuluzi ahlukahlukene kagesi wefrikhwensi ezinhlelweni zamandla, okuhlanganisa i-voltmeter, i-ammeter, i-wattmeter, i-ohmmeter, isigaba esisodwa namamitha wamandla wesigaba sesithathu se-AC (ongakukhetha) kanye nephutha eliyisisekelo DC volt-meter kanye ammeter.
Ngokwengxenye yemitha, kuthatha isiqoqi se-AC sokunemba okuphezulu kwamandla njengobuchwepheshe obuyinhloko, obuhlanganisa iphrosesa yesignali yedijithali (DSP) kanye nesiguquli se-analog-digital esinesivinini esikhulu samadijithi angu-16;Ngomthombo wesignali, isebenzisa i-DSP kanye nesiguquli se-analog-digital esinesivinini esikhulu samadijithi angu-16 ukwakha umthombo wesignali okhiqiza isignali ye-sine wave kanye nesiginali yegagasi lokuhlanekezela.
●Isigaba sokunemba esingu-0.05.Uma i-AC voltage, amandla amanje e-AC kanye namandla asebenzayo kukalwa, idivayisi ifakwe isiguquli sedijithali/imvamisa (i-DFC) enefrikhwensi yokusebenza ephezulu kuno-60kHz nobubanzi bamanje abaningi, ngakho ukunemba okuphezulu kuqinisekisiwe.
●Igagasi lokuhlanekezela lezikhathi ezi-2 ~ 31, inombolo, izikhathi kanye nobukhulu be-harmonics, kanye nesigaba se-harmonic kuya kumagagasi ayisisekelo kungahlelwa konke.
●Isikrini se-TFT LCD esingu-6.5-intshi, isibonisi esicacile nesigqamile.
●Ngechweba lokuxhumana le-RS232.
●Ngememori yomthamo omkhulu ongaguquguquki, ingagcina imiphumela yokuhlolwa engamamitha angu-300 ngaphansi kokuhlolwa, isekela ukubukwa kwedatha nomsebenzi wokulayisha idatha.
●Ngokuthembeka okuhle, kulula ukusebenza.
Imvamisa yamandla okukhiphayo kwe-AC | |
Ibanga lamandla kagesi (V) | 50, 100, 200, 400, 600 (800V uyazikhethela), Ubukhulu.umthamo wokukhipha 20VA |
Ibanga lamanje (A) | 0.5, 1, 2.5, 5, 10, 20, Max.umthamo wokukhipha 20VA |
Ibanga lokulungiswa kwe-voltage | 0~130%, ukulungiswa kwenhlawulo 5*10 |
Ibanga lamanje lokulungiswa | 0~130%, ukulungiswa kwenhlawulo 5*10 |
Ukunemba kwe-voltage, yamanje, amandla asebenzayo namandla | 0.05% |
Ukunemba kwamandla asebenzayo namandla | 0.1% |
Ukunemba kwesigaba se-voltage yamanje ukuya kwesigaba | 0.05° |
Imvamisa | Ibanga lokulungiswa: 45~65Hz, Ukulungiswa kokulunga: 0.001Hz Ukusetha ukunemba kwenani: 0.01Hz |
Isigaba | Ukulungiswa kwebanga: 0~359.99° Ukulungiswa kokuqina: 0.01° Ukusetha ukunemba kwenani: 0.05° |
I-Distortion degree of voltage kanye ne-current output waveform | ≤0.3% |
Ukuzinza kwe-voltage, amandla amanje kanye namandla | ≤0.01%/60s (inani lokuphakama ukuya kwelinye) |
I-Harmonics | 2 ~ 31 izikhathi Ubukhulu: 0~20% Ubulungiswa besigaba: 0.01°*N (“N” isho ukuhleleka kwe-harmonic) |
Ukukhishwa kwe-DC | |
Ibanga lamandla kagesi (V) | 0.075, 75, 150, 300, 500, 1000, Max.umthamo wokukhipha 20W |
Ibanga lamanje (A) | 0.5, 1, 2.5, 5, 10, 20, Max.umthamo wokukhipha 20W |
Ukulungiswa kwebanga le-voltage kanye nelamanje | 0~120% (okungafaki i-1000V), ukulungiswa kwe-fineness 5*10 |
Ukuzinza kwe-voltage nokuphumayo kwamanje | ≤0.01%/60s (inani lokuphakama ukuya kwelinye) |
Ukunemba kwevelu yokusetha i-voltage | 0.05% |
Ukunemba kwevelu yesilungiselelo samanje | 0.1% |
Ukunemba kokuphumayo okungu-75mV (Layisha ≥5Ω) | 0.1% |
Imingcele evamile | |
Ukunikezwa kwamandla kagesi | Isigaba esisodwa 220V±10%, 50Hz±5% |
Sebenzisa izimo | 20℃±10℃, ≤85%RH |
Ubukhulu | 460*460*175mm |
Isisindo | Cishe 20kg |
Miyunithi | 1 isethi |
I-Aluminiumingxube box | 1 isethi |
Intambo yamandla | 1 pc |
Test line nesixhumi | 1 pc |
Ulayini wokuhlola (DC 75mV) | 1 pc |
Umugqa wokuhlola we-electric energy pulse | 1 pc |
Ikhebula lokuxhumana | 1 pc |
Pumqoqi we-hotoelectric | 1 pc |
Umsebenzisi's umhlahlandlela | 1 ikhophi |
Umbiko wokuhlolwa kwefekthri | 1 ikhophi |