I-GDJF-2007 Digital Discharge Analyzer
I-GDJF-2007 Digital Partial Discharge Analyzer isetshenziswa kabanzi ukuthola ukukhishwa kwengxenye yemishini yamandla kagesi aphezulu njengeziguquli zamandla, isiguquli sensimbi, i-HV circuit breaker, i-GIS, i-Zinc oxide surge arrester, ikhebula lamandla.Ingakwazi futhi ukwenza izivivinyo zohlobo futhi iqaphe ukusebenza kwe-insulation.
Ihlanganisa iyunithi eyinhloko, isofthiwe ye-PD, i-transformer yamanje, iyunithi yokufaka, i-calibration pulse generator, i-adaptha yokufaka, i-antenna amplifier nekhebuli yokuxhuma njll.
●Isibonisi se-LCD esingu-12inch, esinomklamo ophathwayo, omangelengele futhi uhlala isikhathi eside, kulula ukuwusebenzisa.
●Ikhono eliqinile lokulwa nokuphazamiseka, elinembile.Ngokusebenzisa ubuchwepheshe bokuhlunga bedijithali, ukuphazamiseka kwensimu kungaqedwa ngempumelelo, futhi ukukalwa kokukhishwa okuyingxenye kungenziwa endaweni eqinile yokuphazamiseka.
●Ukutholwa kwedatha yeziteshi eziningi.Isikrini esisodwa singabonisa iziteshi ezi-2 noma i-4channel waveform.
●Umsebenzi wesoftware onamandla.Ngesilinganiso se-PD, ukuhlaziya, izikhathi zokukhishwa eziphindaphindiwe ze-PD zokulinganisa kwe-N, ukuhlaziya kanye nokuphazanyiswa okuqinile, ukuphazamiseka okunamandla.Ukukhetha kwamahhala kwe-ellipse, umugqa oqondile kanye nemodi yokubonisa ye-sinusoidal.Linganisa futhi Uqaphele ukushaya kwe-pulse ngefasitela, kanye ne-voltage yokuhlola kanye namanje, ukukhishwa okuyingxenye kungalinganiswa ngesikhathi esifanayo.Yonke idatha yokuhlola yeziteshi ezi-2 ingalondolozwa ngesikhathi.I-waveform yokuhlola ingalondolozwa, iphinde iboniswe futhi ihlaziywe.Ibanga lenzuzo lesiteshi ngasinye lingalungiswa libe mahhadla futhi lilungiswe kahle.Ubuchwepheshe bokuvula iwindi bedijithali, ukugwema umthelela wokuphazamiseka esilinganisweni.Ukuvula iwindi lesigaba, iwindi elilodwa kanye newindi eliphindwe kabili kungakhethwa.Iwindi lingavulwa ngokukhululekile phakathi kwama-360degree.
●Ihambisana ne-IEC60270 ejwayelekile.
●Ibanga lamandla: 6pF-250μF
●Ukuzwela: 0.1pc
●Isiteshi sokulinganisa: 2 noma 4pcs iziteshi ezizimele
●Ukunemba kwesampula: 12Bit
●Izinga lesampula: Max.100MHz isiteshi ngasinye
●Ibanga lokulinganisa: 0.1pc-10000nc.
●Ibanga elinamandla: >80db.
●Ibhendi yefrikhwensi yokulinganisa: 10kHz-1MHz ku-3db.
●Ibanga lemvamisa lamandla okuhlola: 50-400Hz.
●Isihlungi esihlelekayo
Imvamisa ephansi: 10K, 20K, 40K, 80K;
Imvamisa ephezulu: 100K, 200K, 300K, 1000K.
●Izinga lokushisa lemvelo: -15℃--50℃
●Umswakama ohlobene: ≤95% (20℃)
●Ukuphakama: ≤3000m.
●Ikhono lomthelela: 5000V endaweni ngayinye yokufaka kanye netheminali yamandla (enhle, engeyinhle kanye ne-AC)
●Okokufaka kwamandla: AC220V±10%, 45-65Hz, amandla <500W.
●Isisindo: mayelana ne-15kg.
●Ubukhulu: 58*36*32CM