I-GDRB-B Transformer Frequency Response Analyzer
I-Power transformer winding deformation tester (indlela yokuphendula imvamisa) isekelwe ekukalweni kwemingcele yesici se-transformer windings yangaphakathi, yamukela indlela yokuhlaziya imvamisa yephutha yangaphakathi (FRA), ingahlulela ngokunembile amaphutha angaphakathi ama-transformer.
Ngemuva kokuphothulwa kokuklama nokukhiqizwa kwama-transformer, amakhoyili kanye nesakhiwo sangaphakathi kuyaqedwa, ngakho-ke ngekhoyili ye-multi-winding transformer, uma izinga le-voltage kanye nendlela yokuphefumula kufana, imingcele ehambisanayo (Ci, Li) ngayinye. ikhoyili izonqunywa.Ngakho-ke, ukusabela kwezimpawu zemvamisa yekhoyili ngayinye nakho kuzonqunywa, ngakho-ke izilinganiso zefrikhwensi zamakhoyili ahambisanayo ezigaba ezintathu ziyaqhathaniswa.
Ngesikhathi sokuhlolwa kwe-transformer, uma kwenzeka kuba ne-inter-turn, inter-phase short circuit, noma ukufuduka kwekhoyili okuhlobene okubangelwa ukushayisana ngesikhathi sokuthutha, kanye nokuguqulwa kwekhoyili okubangelwa ukungezwani kwamandla kazibuthe ngesikhathi sokusebenza ngaphansi kwezimo ezimfushane nezimo zephutha, imingcele yokusabalalisa. ama-windings e-transformer azoshintsha, okuthi ngaleyo ndlela kube nomthelela futhi kuguqule izici zesizinda samafrikhwensi asekuqaleni, okungukuthi ukuguquka kwempendulo yefrikhwensi ngobukhulu kanye nokuguquguquka kwamaphoyinti efrikhwensi.Isihloli sokuvundisa i-transformer esakhiwe ngokwendlela yokuhlaziya impendulo iyinoveli yemishini ye-NDT yokuthola iphutha langaphakathi le-transformer.Kusebenza ekutholweni kwephutha lesakhiwo sangaphakathi kuma-transformer amandla angu-63kV-500kV.
Umhloli we-Transformer winding deformation ukunquma izinga lezinguquko kuma-winding angaphakathi e-transformer ngokusekelwe enanini loshintsho, ubukhulu kanye nesifunda esithinta ushintsho kanye nokuthambekela kokushintsha kwe-frequency impendulo ebalwa kusukela ekushintsheni kwempendulo ezizindeni ezihlukene zefrikhwensi yamajika angaphakathi e-transformer. imingcele, bese ingasiza ekunqumeni ukuthi i-transformer yonakaliswe kakhulu, noma idinga ukulungiswa okukhulu ngokuhambisana nemiphumela yokulinganisa.
Ku-transformer esebenzayo, kungakhathaliseki ukuthi umdwebo wesici sesizinda se-frequency ulondoloziwe, ngokuqhathanisa umehluko phakathi kwe-spectra yesici se-inter-coil ye-transformer enephutha, inganquma izinga lokuhluleka futhi.Yiqiniso, uma ulondoloze imidwebo yesici sokuqala se-transformer windings, kuyoba lula ukunikeza isisekelo esiqondile sezimo zokusebenza, ukuhlaziywa kwe-post-fault kanye nokulungiswa kokugcinwa kwe-transformer.
Umhloli wokuguquguquka ojikajikayo we-Transformer wakhiwa ikhompuyutha ephathekayo nesilawuli esincane esakha isistimu yokulinganisa ukunemba ngesakhiwo esihlangene, ukusebenza okulula, nomsebenzi wokuhlaziya ophelele kakhudlwana, ongasetshenzwa kubhekiselwa kumanuwali weziqondiso noma ngokuqeqeshwa kwesikhashana.
●Ukuthola nokulawula kusetshenziswa i-microprocessor enesivinini esikhulu, edidiyelwe kakhulu.
●Isixhumanisi esibonakalayo se-USB sokuxhumana esisetshenziswa phakathi kwekhompyutha ephathekayo nensimbi.
●Isixhumi esibonakalayo se-WIFI engenantambo noma i-Bluetooth (uyazikhethela) esetshenziswa phakathi kwekhompyutha ephathwayo kanye nensimbi.
●Izingxenyekazi zekhompyutha zamukela ubuchwepheshe bokuskena bejubane eliphezulu be-DDS yedijithali (i-USA), obungakwazi ukuhlonza ngokunembile amaphutha njengokuphenduka okusontekile, okugobile, ukuguquka, ukutsheka, ukuguquguquka kwe-inter-turn short-circuits kanye ne-inter- phase contact short-circuit.
●Isampula ye-speed dual-channel 16-bit A/D (esivivinyweni senkambu, hambisa isishintshi sompompi, futhi ijika lamagagasi libonisa izinguquko ezisobala).
●I-amplitude yokuphuma kwesignali ilungiswa isofthiwe, futhi inani eliphakeme le-amplitude ngu-± 10V.
●Ikhompyutha izozihlaziya ngokuzenzakalelayo imiphumela yokuhlolwa bese ikhiqiza imibhalo ye-elekthronikhi (iZwi).
●Ithuluzi linezici zokulinganisa ezimbili: ukulinganisa imvamisa yokuskena okuqondile kanye nesilinganiso sokuskena imvamisa yengxenye, ehambisana nemodi yokulinganisa yamaqembu amabili obuchwepheshe e-China.
●Izici ze-amplitude-frequency zihambisana nezicaciso zobuchwepheshe kazwelonke kumhloli wezimpawu ze-amplitude-frequency.I-X-coordinate (imvamisa) inokukhomba ngomugqa kanye ne-logarithmic indexing, ngakho-ke umsebenzisi angakwazi ukuphrinta ijika nge indexing yomugqa kanye ne-logarithmic indexing.Umsebenzisi angakhetha noma ngokwezidingo zangempela.
●Uhlelo lokuhlaziya idatha oluzenzakalelayo,
Ukuqhathaniswa okuvundlile kokufana okumazombezombe phakathi kwezigaba ezintathu A, B kanye no-C
Imiphumela imi kanje:
●Ukuvumelana okuhle kakhulu
●Ukuvumelana okuhle
●Ukungaguquguquki okungalungile
●Ukungaguquguquki okubi kakhulu
Ukuqhathaniswa kobude i-AA, BB, CC kubiza idatha yoqobo kanye nedatha yamanje esigabeni esifanayo sokuqhathanisa ukuwohloka kokuphenduka
Imiphumela yokuhlaziya ithi:
●Ukusonteka okujwayelekile
●I-deformation encane
●I-deformation emaphakathi
●Ukuguqulwa okukhulu
Idokhumenti ye-elekthronikhi ye-Word ingakhiqizwa ngokuzenzakalela ukuze igcinwe futhi iphrinte.
Ithuluzi lingahlangabezana ngokugcwele nezidingo zobuchwepheshe ze-DL/T911-2004 ejwayelekile kagesi "Ukuhlaziywa kwempendulo yemvamisa ekuwohlokeni okugoqayo kwama-transformer amandla".
Imodi yokuskena:
1. Ukusatshalaliswa kokuskena ngomugqa
Ibanga lokulinganisa lokuskena: (10Hz) -(10MHz) 40000 iphoyinti lokuskena, ukulungiswa okungu-0.25kHz, 0.5kHz kanye no-1kHz.
2. Ukusatshalaliswa kokulinganisa imvamisa yesegimenti
Ibanga lokulinganisa imvamisa yokuskena: (0.5kHz) - (1MHz), amaphuzu wokuskena angu-2000;(0.5kHz) - (10kHz);(10kHz) - (100kHz);(100kHz) - (500kHz);(500kHz) - (1000kHz)
Eminye imingcele yezobuchwepheshe:
1. Ibanga lokulinganisa i-amplitude: (-120dB) kuya ku-(+20 dB);
2. Ukunemba kwesilinganiso se-amplitude: 1dB;
3. Ukunemba kwemvamisa yokuskena: 0.005% / 0.01%;
4. Ukuvimbela okokufaka kwesignali: 1MΩ;
5. Ukuphazamiseka kokuphuma kwesignali: 50Ω;
6. I-amplitude yokukhishwa kwesignali: ± 20V;
7. Izinga lokuphinda ukuhlolwa kwesigaba: 99.9%;
8. Ubukhulu bezinsimbi zokulinganisa (LxWxH): 350*300*140 (mm) / 300*340*120 (mm);
9. Ubukhulu bebhokisi le-aluminium yensimbi (LxWxH): 390*310*340 (mm) / 310*400*330 (mm);
10. Isisindo sisonke: 13kg/10kg;
11. izinga lokushisa lokusebenza: -10℃~+40℃;
Izinga lokushisa lesitoreji: -20℃~+70℃;
Umswakama ohlobene: <90%, Okungajiki;
Iyunithi eyinhloko | 1 |
Ukuhola kokuhlolwa kwemvamisa okungu-50W/(>15m) | 2 |
I-clamp yokuhlola, ephuzi, eluhlaza (200A) | 2 |
Intambo yaphansi (emnyama, intambo yethusi engu-5M) | 4 |
I-Grounding clamp(emnyama) | 2 |
Ikhebula lokuxhumana le-USB | 1 |
Ukufakwa Kwesofthiwe Ifomethi ye-VCD ye-CD-ROM | 1 |
Ukufaka Isoftware ye-USB disk 16G | 1 |
I-Fuse 0.5A | 3 |
Intambo yamandla ne-adaptha | 1 |
Igayidi yomsebenzisi | 1 |
Ikhadi lewaranti | 1 |
Uhlu lokupakisha | 1 |
Umbiko wokuhlolwa kwefekthri | 1 |