I-GDYB-D24 Uhlelo Lokuhlola Imitha Yamandla Esilodwa Isigaba
●Umklamo onengqondo nokubukeka okuhle.Uhlaka lwetafula lokulenga idivayisi kanye nohlaka lomzimba wetafula konke kwenziwa ngezinto ezikhethekile ze-aluminium alloy, futhi phezulu kwetafula kwenziwa ngezinto zefiber ezingashi nokumelana nokushisa.Yonke idivayisi inemibala ethambile, izilinganiso ezihlanganisiwe, nesakhiwo esithembekile.Ubuciko obuhle, ukubukeka okuhle.
●Ukusebenza kwekhibhodi ezinikezele nokusebenza kwe-PC kuhlangene, kulula ukuyisebenzisa.Le divayisi ifakwe ikhibhodi, ikhibhodi iza nesibonisi sekristalu ewuketshezi, futhi isimo sokusebenza sedivayisi sisobala lapho uthi nhla.Ukusebenza kulula futhi kumahhala.Isoftware yokulawula i-PC inamazinga acacile, isikhombimsebenzisi esihle, nokusebenziseka kalula nokusebenziseka kalula.
●Izinga eliphakeme lokuzenzakalelayo.Lapho uqinisekisa imitha yamandla kagesi, udinga kuphela ukubamba iqhaza ewashini ngesandla, ulungise isampula ye-photoelectric, futhi uklame ngendlela efanele imingcele yemitha, zonke izinto zokuqinisekisa (okuhlanganisa ukushisa kwangaphambili, ukuhlolwa kwe-creep, ukuhlolwa kokuqala, ukunqunywa kokuphambuka okujwayelekile, kanye nokunqunywa kwephutha eliyisisekelo) ) Ilawulwa ngokuzenzakalelayo yi-PC futhi iqedwe ngesikhathi esisodwa.Inqubo yokulinganisa ingaba ngokuhambisana nemithetho kazwelonke noma ingenziwa ngokwezifiso ngumsebenzisi.
●Isampula ye-photoelectric ingakwazi ukubona ukulungiswa kwezinhlangothi ezintathu, futhi ingasampula isignali ephendukayo yemitha yamandla kagesi ejikelezayo.Ingakwazi futhi ukuthola isignali ye-stroboscopic yemitha yamandla kagesi.
●Isistimu yokucubungula iphutha ingathola isignali yesampula yesithombe, i-pulse ephumayo yemitha ye-electronic efakwe kanye nesignali ye-high-frequency pulse yemitha yamandla kagesi evamile.
●Amamitha wamandla ohlobo olufanayo (i-voltage elinganiselwe efanayo kanye nokulinganisa kwamandla) kanye nama-constants ahlukene angalinganiswa ngesikhathi esisodwa (kukhawulelwe kuma-constants amabili).
●Ingakwazi ukuthola ngokuzenzakalelayo uphawu olumnyama lwe-turntable yemitha yamandla kagesi ejikelezayo, elungele ukuhlolwa kwe-diving (ukuqala).
●Ama-harmonics angu-2 kuye kwangama-21 angabekwa phezulu kugagasi oluyisisekelo lwemvamisa yamandla, futhi i-amplitude nesigaba sama-harmonics singasethwa njengoba kudingekile.Ingakwazi futhi ukwenza ukuhlaziya kwe-harmonic kokuphumayo futhi idwebe i-waveform.
●Idivayisi inokuqina okuphezulu, ukwethembeka okuhle namandla amakhulu okukhipha.Iluphu ye-voltage (yamanje) ingathwala imithwalo yanoma yiluphi uhlobo.
●Ukutholwa kwamaphutha okuphelele, indawo, ukuvikeleka kanye nemisebenzi ye-alamu ukugwema ukulimala ocingweni ngenxa yamaphutha ezintambo enziwe umuntu noma okusebenza.
●Isofthiwe yokuphatha i-PC futhi inemisebenzi efana nokuphrinta umbiko ophelele, izibalo zezibalo nokugcinwa kwempahla.
Ukunemba kwesistimu: 0.05%, 0.1%.
●Amandla kagesi okukhiphayo: 220V, ububanzi obulungisekayo: (0%~120%)x ububanzi bokulinganisa, ukucoleka okulungiswayo: okungcono kuno-0.01%.
●Isinyathelo samanje sokuphuma: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A.ububanzi obulungisekayo: (0%~120%) x ububanzi bokulinganisa, ukucoleka okulungisekayo: okungcono kuno-0.01%.
●Amandla okukhiphayo: iluphu ye-voltage: 300VA, iluphu yamanje: 500VA.
●Ukuzinza kwe-voltage ephumayo, yamanje namandla:
≤0.02%/120S PF=1 (Ikilasi 0.05)
≤0.05%/120S PF=1 (Ikilasi 0.1)
●Ukuhlanekezelwa kwegagasi kwe-voltage ephumayo neyamanje: ≤0.5%
●Ibanga lemvamisa: 45Hz-65Hz okulawula ukunemba: 0.01 Hz
●Ububanzi bokushintsha kwesigaba: -180.0°~180.0° ukunemba kokulawula: 0.01°
●Ikhombisa isigaba sezinsimbi
●Ukunemba kwe-Voltmeter: ileveli ±0.2%
●Ileveli yokunemba kwe-ammeter ±0.5%
●Ukunemba kwemitha yesigaba: ±0.5°
●Ukunemba kwemitha yemvamisa: ±0.1Hz
●Umkhawulo wamamitha wokuhlolwa: 12pieces
●Ukunikezwa kwamandla: 220V±10%, 50Hz (noma 120V±10%, 60Hz)
●Ukusetshenziswa kwamandla okuphezulu: 800VA
●Izinga lokushisa elisebenzayo: 20 ± 5℃ umswakama ohlobene: ≤85%
●Ubukhulu nesisindo: 2000mm*720mm*1550mm 280Kg