I-GDYM-1A I-Single Phase Electric Energy Meter Calibrator
I-GDYM-1A Isigaba Esisodwa I-Electric Energy Meter Calibrator iyithuluzi lokulinganisa lamapharamitha amaningi eligcwele idijithali, i-mullti-function kanye nokunemba okuphezulu.Ayinikezi kuphela amandla ukulinganisa iphutha, kodwa futhi nokukala i-voltage, inani elisebenzayo lamanje, amandla asebenzayo, amandla asebenzayo, amandla abonakalayo, imvamisa yamandla, isici samandla, ubudlelwano besigaba, njll. Ifaneleka ngokukhethekile ukulinganisa ukunemba kokulinganisa Imitha yamandla kagesi yesigaba esisodwa kuyunithi yokuphakela amandla.
Ukusebenza okulula nokusheshayo, zonke izinqubo zokusebenza ziboniswa esikrinini.
●Ukulinganisa imitha yamandla kagesi yohlelo lokulinganisa nokukala isilinganiso se-voltage ephansi.
●Kusetshenziswa ubuchwepheshe bamuva be-32 bit 150MHz DPS core, isiguquli esinembayo esingu-16 bit high, iphutha lizinzile futhi ukunemba kuphakeme (lokhu kunomehluko wekhwalithi ngesilinganisi sesigaba esisodwa esine-chip yemitha).
●Isikrini esikhulu se-LCD esimibalabala, sibonisa amapharamitha wokusetha wokulinganisa, i-harmonic, amapharamitha kagesi, iphutha nayo yonke idatha yokulinganisa ngamandla.
●I-clamp yamanje isetshenziselwa ukulingisa okwamanje okukhiqizwa umthwalo, okwenza insimu ibe lula ukusebenza futhi yathuthukisa ukusebenza kahle komsebenzi.Amandla amanje etheminali kanye ne-clamp kanye namandla azo nesamba samandla azoboniswa ngesikhathi esifanayo.
●Ukusebenzisa i-clamp engu-500A kanye ne-clamp yamanje encane ukukala isilinganiso se-voltage ephansi ye-CT.
●Kala idatha ye-harmonic kusukela ezikhathini ezingu-2-43, yamanje kanye ne-voltage izobonisa ngesikhathi sangempela i-waveform ngayinye, esiza ukwahlulela isimo esikusayithi.
●Ibala ukungaguquguquki kwemitha yamandla esikhathini esisodwa sokushaya kwamandla kagesi.
●Londoloza idatha ngamamitha angu-1000.
●Xhuma nge-PC ngochungechunge lokuxhumana lwe-RS232 interface.
●Ngokukhishwa kweshayela okuvama okuphansi, okulula ukuzihlola nokuzihlola.
●Isikali sizohlaba umkhosi ngomsindo nangokukhanya lapho sinikezela nge-380V kulayini wokuhlola i-voltage.
●Uma umugqa wamanje wokulingisa ungalungile oxhunywe emugqeni omaphakathi wemitha, ukuvikela kokuqala okuzenzakalelayo ngeke kukhiphe okwamanje.Uma wenza uxhumano lwephutha futhi, i-fuse yesibili yokuvikela izoshiswa, okusebenza ukuvikela ngokuphelele.I-calibrator izolulama ngemva kokufaka i-fuse.
●I-fuse izosha umaumugqa we-impulse hit 220V, i-calibrator izolulama ngemva kokufaka i-fuse.
Ibanga Lokulinganisa | Ukunemba | ||
Amandla kagesi | 10-300V | ±0.1% | |
Ukulingisa kwamanje | 5A | ±20% | |
I-Clamp Yamanje | 100A, 500A | ±0.3%, ±0.5% | |
Itheminali yamanje | 0.05-10 A | ±0.1% | |
Amandla | I-Clamp Yamanje | 100A, 500A | ±0.3%, ± 0.5% |
Isikhumulo | 10A | ±0.1% | |
I-Engeli yesigaba | -180-+180° | ±0.1° | |
Imvamisa | 45-55Hz | ±0.01Hz | |
Amandla kagesi | I-100A Clamp(encane) | 0.25A-110A | ±0.3%, ±0.5% |
I-500A Clamp | 25-1000A | ±0.5% | |
Ububanzi Bokubonisa | I-100A Ukubambelela Kwamanje: 0.01A-110A | ||
Itheminali: 0.01A-10A | |||
I-Electric Energy Pulse | FL=1000 imp/kW.h | ||
I-Voltage esebenzayo | I-AC 100 - 300 V | ||
Izinga Lokushisa Lokusebenza | -25 ℃~45℃ | ||
Umswakama Osebenzayo | <95% Akukho ukujiya | ||
Isisindo | <1kg | ||
Ivolumu | 215*105*70mm |
I-GDYM-1A Calibrator | 1 isethi |
100A imitha yokubopha | 1 izingcezu |
Isoftware Yokuphatha (CD-ROM) | 1 isiqephu |
I-Electronic meter pulse line | 1 isiqephu |
Ikhebula le-voltage | 1 isiqephu |
Ikhebula lamandla | 1 isiqephu |
232 ulayini wokuxhumana | 1 isiqephu |
Ikhanda likagesi wesithombe | 1 isiqephu |
0.5A Fuse | 1 isiqephu |
Ikesi lezinsimbi | 1 isiqephu |
Imanuwali | 1 ikhophi |