I-GDYM-3M Multi-functional Electric Energy Meter Calibrator
Izici zakamuva
1. 32-bit high speed high signal processor
Isebenzisa isivinini esiphezulu esingu-32-bit esingu-120MHz DPS ye-TI, nokusebenza okuphezulu okungu-16-bit AD namashaneli angu-6.Amayunithi okuphindaphinda edijithali anemisebenzi eminingi kanye nohlu olubanzi lokulinganisa athuthukiswe ngempumelelo ngokusebenzisa izibalo zamaphuzu antantayo.Ngakho-ke, ukunemba kokubala kungaqinisekiswa.
2. Wring sekulingisa umsebenzi
Izindlela ezihlukahlukene zokufaka izintambo zingalingiswa futhi zithole imiphumela yazo ehambisanayo ehhovisi nge-calibrator ngaphandle kokuxhuma amandla kagesi noma amasignali amanje.Lo msebenzi uzosetshenziswa njengezinto zokuqeqesha kanye namathuluzi okuqeqesha amakhono okuhlola umugqa.Ivumela ukuthuthukisa kakhulu amakhono okuhlola abasebenzi abasebenza endaweni.
3. Iphutha ekuzihloleni ukuthi i-5A clamp
Isignali yamanje engu-5A kanye ne-0.5A izokhiqizwa futhi ikhishwe ku-5A kanye ne-100A clamp, ukuze kulinganiswe amaphutha e-clamp.Ixazulule inkinga yokuhluka kwephutha ye-5A kanye ne-100A clamp ngemva kokusetshenziswa isikhathi eside, okwenza opharetha aqonde isimo sokuvala se-clamp futhi akhumbuze izinti ukuthi zisule umhlathi we-clamp kusenesikhathi.
4. Ibanga lamanje lokulinganisa elibanzi kakhulu
Kufika izikhathi ezingu-500 ububanzi bamanje bokulinganisa ukuze kuqinisekiswe inkomba yokulinganisa.Kufika izikhathi ezingu-10000 ububanzi bamanje bokuboniswa.Isilinganiso esincane sokuqala samanje ngu-1mA.Izintambo zingabonakala ngisho nasesimweni sokungalayishi.
5. Umsebenzi onqwabelene wamandla kagesi
Ukulinganisa imitha yamandla ngaphandle kwe-electronic energy pulse output.Noma ingabhekwa njengenkomba yokuhlola ukonga amandla.
6. Ukuhlola okungenantambo
Ukuhlolwa okuphelele kwamaphutha ohlelo lokulinganisa endaweni, kubhekwa iphutha eliyinhlanganisela lamandla kagesi aphezulu kanye ne-voltage ephansi.
Ezinye izici
1. Isebenzisa isikrini se-LCD esingu-4.7 amayintshi esingu-16:9 TFT LCD, ukusebenza okucacile nokuhle, ukulungiswa okuphezulu, ulwazi oluningi nokuqukethwe okucebile.Umsebenzi ngamunye wesikali uboniswa esikrinini esisodwa, asikho isidingo sokuphenyisisa isikrini ukuze ubone wonke amapharamitha omsebenzi ngamunye.Kwenza abasebenzisi kucace ngokuphelele mayelana ne-calibrator ngesikhathi sokusebenzisa..
2. Amaphutha, i-voltage, amandla amanje, asebenzayo futhi asebenzayo, isigaba, imvamisa, kanye nesici samandla kungalinganiswa ngesikhathi esisodwa, nesibalo se-vector nemiphumela yezintambo izoboniswa.
3. Ngaphandle kwanoma iyiphi i-resistor elungisekayo kusikali, wonke amaphutha azolungiswa isofthiwe.
4. Isilinganiso se-CT ye-voltage ephansi singalinganiswa ngokuqondile nge-clamp engu-5A, 100A, 500A, 1000A.Wonke amaphutha, njengokunqanyulwa kokuxhumeka, ukuxhumeka okungalungile kwesekethe yesibili ye-CT, isifunda esifushane sokujika ngaphakathi kwe-CT, kanye nesilinganiso se-nameplate ye-CT sihambisana nesilinganiso sangempela sokuphenduka kwe-CT noma cha, njll. kuzotholwa.
5. I-voltage kanye ne-harmonic yamanje kusukela ku-2 kuya ku-21 izikhathi ze-A, B, C isigaba singalinganiswa ngesikhathi sangempela ukwazi ikhwalithi kagesi yegridi yamandla.
6. Ifomu legagasi le-A, B, C lesigaba sesithathu se-voltage noma lamanje lingalinganiswa futhi liboniswe.
7. Ububanzi be-voltage ebanzi ukusuka ku-45V ukuya ku-480V.
8. Wonke amapharamitha okufakwayo esizeni kanye nedatha kungachazwa ngabasebenzisi.Idatha yomsebenzisi engu-1000 ingalandwa.
●Isikali sizohlaba umkhosi ngomsindo nangokukhanya lapho sinikezela nge-380V kulayini wokuhlola i-voltage.
●Uma umugqa wamanje wokulingisa ungalungile oxhunywe emugqeni omaphakathi wemitha, ukuvikela kokuqala okuzenzakalelayo ngeke kukhiphe okwamanje.Uma wenza uxhumano lwephutha futhi, i-fuse yesibili yokuvikela izoshiswa, okusebenza ukuvikela ngokuphelele.I-calibrator izolulama ngemva kokufaka i-fuse.
●I-fuse izosha umaumugqa we-impulse hit 220V, i-calibrator izolulama ngemva kokufaka i-fuse.
I-Voltage Range | 30V-480V | 5A Isikhwama | Amandla asebenzayo, amandla | ±0.5% | |
Iphutha le-Voltage | ±0.2% | Amandla asebenzayo, amandla | ±0.5% | ||
I-Clamp (izikhathi ezingu-1 ukulayisha ngokweqile) | 5A,100A,500A,1000A | Okwamanje | ±0.5% | ||
Ibanga Lefrikhwensi Yokufaka | 45-55Hz | Ukuzihlola Kwamanje | 5A 0.5A | ||
Iphutha Lokukala Imvamisa | ±0.01Hz | Iphutha lokuzihlola | ±0.1% | ||
Ibanga Lokulinganisa Isigaba | -180°~ +180° | I-Clamp Yamanje Enkulu | Amandla asebenzayo, amandla | ±0.5% | |
Iphutha Lesigaba Esikhulu | ±0.1° | Amandla asebenzayo, amandla | ±0.5% | ||
Isilinganiso se-Harmonic | ±0.1% | Okwamanje | ±0.5% | ||
I-Harmonic Measurement Range | 2-51 izikhathi | Abanye | Ukukala Isilinganiso | ±0.5% | |
Itheminali yamanje | Amandla wamandla asebenzayo | ±0.1% | Ithonya lamandla kagesi | < ±0.01% | |
Amandla wamandla asebenzayo | ±0.5% | Ukuthonya Imvamisa | < ±0.01% | ||
I-Low Frequency Pulse Constant | 5A | 3600P/kWh | Ithonya Lezinga Lokushisa | < ±0.005%/ºC | |
Abanye | 3600*(5/Ie) | Iphutha lokushintsha lamahora angu-24 | < ±0.04% | ||
I-P/kWh | |||||
Ithonya Harmonic | < ±0.01% | ||||
Qaphela: Ie ikalwe okwamanje | Isikhathi sokulinda ngemuva kokuqala | ||||
Ukunikezwa kwamandla kagesi | I-AC 45V - 480V | Izinga lokushisa kwemvelo | -25ºC- +45ºC | ||
Ukusetshenziswa kwamandla | <10W | Umswakama ohlobene | 40%-95% | ||
Ubukhulu | 214mm * 158mm * 71mm | Isikhathi sokusebenza esiqhubekayo sebhethri | > 8 amahora | ||
Isisindo | < 1.2 kg | I-voltage yokushaja ibhethri | I-DC 12V |
I-GDYM-3M Calibrator | 1 isethi |
100A imitha yokubopha | 3 izingcezu |
Indandatho yokulungisa | 1 isiqephu |
Isoftware Yokuphatha (CD-ROM) | 1 isiqephu |
Umholi wokuhlola | 1 isiqephu |
I-Electronic meter pulse line | 1 isiqephu |
Ikhebula lamandla | 1 isiqephu |
232 ulayini wokuxhumana | 1 isiqephu |
Ikhanda likagesi wesithombe | 1 isiqephu |
I-adaptha | 1 isiqephu |
Ikesi lezinsimbi | 1 isiqephu |
Imanuwali | 1 ikhophi |