Muva nje, amakhasimende ase-Foshan, e-Guangdong athenge iqoqo le-GDYT lochungechunge lwe-PD-Free Test Set ku-HV HIPOT.Ngokubambisana okusebenzayo kozakwethu bokukhiqiza kushabhu, futhi ngokuya ngosuku lokulethwa kwenkontileka, iqoqo lamadivayisi okuhlola lihloliwe futhi lathunyelwa ngokushelela.
I-GDYT yochungechunge lwe-PD-Free Test Set isetshenziselwa ikakhulukazi imvamisa yamandla ukumelana nokuhlolwa kwe-voltage yama-transformer, ama-transformer kagesi, ama-high-voltage circuit breaker, ama-coupling capacitor, ama-capacitor bushings, amaswishi, njll., ukuhlola ukumelana kwezinto ezihlukahlukene zokufakelwa kanye nezakhiwo zokufakelwa .Izinga le-insulation lingaphansi kwe-voltage yefrikhwensi yamandla.Ngesikhathi esifanayo, ukulinganisa okuyingxenye yokukhishwa kwemikhiqizo engenhla nakho kungenziwa.
ukwakheka komkhiqizo:
- Imvamisa yamandla imelana nedivayisi yokuhlola i-voltage: ukulawula ukuphuma kwe-voltage ephezulu eshiwo ye-transformer ngaphandle kokuhlolwa kokukhishwa okuyingxenye,
- Umtshina wokukhipha ingxenye ethile: Hlaziya futhi uthole i-pulse yokukhipha ekhiqizwe umkhiqizo wokuhlola, bonisa i-pulse waveform ngezindlela ezihlukahlukene zokuhlaziya;
- Ayikho i-transformer yokuhlola ukukhishwa okuyingxenye: I-transformer yokuhlola ukukhipha okungaphelele ihlinzeka ngokuhlinzeka kwamandla kagesi aphezulu ezinzile kulo lonke isethi yezisetshenziswa zokuhlola.
- Idivayisi yokuhlukanisa kanye nokuhlunga: Ukunikezwa kwamandla kagesi aphezulu okunikezwa isiguquli sokuhlola siguqulwa sibe ugesi ocwenge kakhulu we-voltage ephezulu ngokusebenzisa idivayisi yokuhlukanisa nokuhlunga;
- Ngaphandle kokukhishwa okuyingxenye kwe-coupling capacitor: Thola isignali ye-pulse kumjikelezo we-voltage ephezulu futhi uthole ukukhishwa okuyingxenye komkhiqizo ohloliwe ngethuluzi lokukhipha ingxenye;
- Ukumelana nokuvikela: vikela imishini yokuhlola amandla kagesi aphezulu kanye nomkhiqizo ohloliwe;
Izici:
- Kuthuthukiswe ngempumelelo isilinda sokuvikela i-epoxy esingenasici esinenani elincane lokukhipha ingxenye.
- I-voltage ye-impedance iphansi, engcono kunezinga likazwelonke.
- Isebenzisa ubuchwepheshe bokulawula okuzenzakalelayo, inezinga eliphezulu lokuzenzakalela kanye nekhono eliqinile lokulwa nokuphazanyiswa.
- Ukusebenzisa idivayisi yokuvikela esheshayo ye-elekthronikhi, ukwethembeka okuphezulu.
I-HV HIPOT izuze ukutuswa okuvela kumakhasimende “ngokuklama komkhiqizo okunengqondo, ikhwalithi ezinzile nethembekile, isevisi yekhwalithi ephezulu nefike ngesikhathi”, ikhwalithi yomkhiqizo omuhle kakhulu, kanye nesevisi ephelele ngemva kokuthengisa.Isekela isimiso sekhasimende kuqala futhi iphikelela ekudaleni ukuhlolwa kokuvimbela amandla okusezingeni eliphezulu embonini yokulinganisa kagesi.Umkhiqizi wezisetshenziswa.
Isikhathi sokuthumela: Nov-19-2021