Partial Discharge Measurement Device

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350, 3.5inch TFT LCD screen.

     

     

     

  • Partial Discharge Online Monitoring System of GIS

    Partial Discharge Online Monitoring System of GIS

    Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. 

  • Partial Discharge Online Monitoring System of Generators

    Partial Discharge Online Monitoring System of Generators

    Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform.

  • GDJF-2006 Partial Discharge Analyzer

    GDJF-2006 Partial Discharge Analyzer

    GDJF-2006 Digital Partial Discharge Detector is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation.

  • GDPD-313P Hand-held Partial Discharge Detector

    GDPD-313P Hand-held Partial Discharge Detector

    The hand-held partial discharge detector is used to detect and measure the instantaneous ground voltage discharge and surface discharge in the switch cabinet and display the discharge waveform and discharge amount in real time on the LCD screen. The instrument adopts a pistol-portable design, which can be scanned and detected directly on the switchgear shell without any influence or damage to the operation of the switchgear. At the same time, the measured signals can be stored and played back on the TF card. The matching headphones can hear the sound of the discharge.

  • GDJF-2007 Digital Partial Discharge Analyzer

    GDJF-2007 Digital Partial Discharge Analyzer

    GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable.

     

  • GDJF-2008 Partial Discharge Analyzer

    GDJF-2008 Partial Discharge Analyzer

    GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation.

  • GDPD-505 Portable Partial Discharge Detector

    GDPD-505 Portable Partial Discharge Detector

    GDPD-505 is a portable multi-functional PD online detector, which is suitable for testing transformers, GIS, switch cabinet, power cables, lightning arrester and CT/PTs.

    The system includes detector, software, HFCT(high frequency current transformer), calibration pulse generator, 40kHz ultrasonic sensor, 150kHz ultrasonic sensor, UHF sensors, TEV sensors, Acoustoelectric sensors and some connection cables.

    It uses pulse current, ultrasonic and UHF technology, to detect and analyze HF electromagnetic signals and ultrasonic signals of internal transformers and GIS, so that to detect and evaluate the running status of GIS, transformers.

     

     

     

     

     

     

  • GDPD-414H Handheld Partial Discharge Detector

    GDPD-414H Handheld Partial Discharge Detector

    The GDPD-414H handheld Partial Discharge Detector uses smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481), which can flexibly configure various sensors according to different test objects.

     

     

  • GDPD-316M Handheld Partial Discharge Detector

    GDPD-316M Handheld Partial Discharge Detector

    The GDPD-316M handheld Partial Discharge Detector uses smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detection of insulating status of GIS; Ultrasonic and HFCT are suitable for detection of insulating status of power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway.

12 Next > >> Page 1 / 2

Send your message to us:

Write your message here and send it to us