I-AC High Voltage Test Isethi ye-GIS

I-AC High Voltage Test Isethi ye-GIS

Incazelo emfushane:

I-AC Resonant Test System Yezisetshenziswa Zogesi Ezingaphansi, ikakhulukazi yakhiwe ukuphakelwa kwamandla kagesi okuguquguqukayo, Ama-Excitation Transformers, Ama-Reactors, ama-Capacitive dividers, aklanyelwe i-AC ukumelana nokuhlolwa kwamandla kagesi wesiteshi esincane sikagesi ku-500kV noma ngaphansi.

 


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Izinhlelo zokusebenza

I-Transformer
Uhlelo lwe-GIS
SF6 switchgear
Amakhebula
Bushing
Isivikelo
I-CT/PT
Amanye amadivaysi e-capacitive

Izici

Izinga lokushisa elincane likhuphuka ngomthwalo olinganiselwe.Ama-reactors ohlobo olomile noma uwoyela, amandla aphezulu emishini, ukufakwa kahle kwezinto, okuhle futhi okuthembekile.
Umthamo olungisekayo womthombo wokulawula imvamisa.Ukuvikelwa okuqinile, ukuzinza okuhle.Ngemodi yokusebenza eminingi, kulula ukuyisebenzisa.
Ngamandla wesigaba esisodwa angu-220V noma angu-380V, alungele ukutholakala kwamandla esizeni.
Ukucushwa okuguquguqukayo.Ama-reactor ohlobo oluhlukile ngokuzikhethela, ahlangabezana nezidingo zento yokuhlola ehlukile.Imisebenzi eminingi, ibiza ngempumelelo.

Imininingwane

I-voltage elinganiselwe yokuphumayo: ngokusekelwe ezintweni zokuhlola ezihlukene.
Imvamisa yokuphuma: 20- 300Hz.
I-Waveform: i-sine wave ehlanzekile, i-THD <1.0%.
Ubukhulu.amandla: 1000kVA nangaphansi.
Umjikelezo Womsebenzi: Isikhathi sokusebenza esiqhubekayo 15mins ngesikhathi esisodwa ekuphumeni kwamandla agcwele.(noma isidingo samakhasimende.)
Ukuzwela kokulungiswa kwemvamisa: 0.1Hz, ukungazinzi <0.05%.
Ukunikezwa kwamandla: 380/220V ± 15%/50Hz ± 5%.

Ukucushwa komkhiqizo

GDTF-108/108

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-108

Amandla (kVA)

108

Ububanzi bohlelo lokusebenza

31500kVA noma ngaphansi

35kV i-transformer yamandla

I-35kV i-circuit breaker kanye nebha yebhasi, ama-insulators

10kV (300 mm²) ikhebula 2000m

35k V (300 mm²) ikhebula 500m

Ukucushwa okuyinhloko

5kW Umthombo wefrikhwensi eguquguqukayo 1 isethi

5kVA I-transformer ejabulisayo isethi engu-1

Ama-reactors angu-27kV/1A 4sets

I-Capacitive divider engu-100kV

GDTF-216/216

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-216

Amandla (kVA)

216

Ububanzi bohlelo lokusebenza

110kV Circuit breaker kanye nebhasi

110kV GIS

35kV(300 mm²) ikhebula 1500m

10kV(300 mm²) ikhebula 3km

110kV full insulation Transformer

Ukucushwa okuyinhloko

10kW Umthombo wefrikhwensi eguquguqukayo isethi engu-1

10kVA I-transformer ejabulisayo isethi engu-1

Ama-reactors angu-54kV/1A 4sets

Isihlukanisi se-Capacitive 200kV

GDTF-270/270

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-270

Amandla (kVA)

270

Ububanzi bohlelo lokusebenza

110kV GIS kanye ne-transformer

110kV GIS kanye ne-transformer

35kV (300 mm²) ikhebula 2km

Ukucushwa okuyinhloko

15kW Umthombo wefrikhwensi eguquguqukayo 1 isethi

15kVA I-transformer ejabulisayo isethi engu-1

Ama-reactors angu-54kV/1A 5set

Isihlukanisi se-Capacitive 300kV

I-GDTF-400/400

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-400

Amandla (kVA)

400

Ububanzi bohlelo lokusebenza

220kV GIS kanye ne-transformer

10kV (300 mm²) ikhebula 4km

Ikhebula engu-35kV (300 mm²) 1km

Ukucushwa okuyinhloko

20kW Umthombo wefrikhwensi eguquguqukayo isethi engu-1

20kVA I-transformer ejabulisayo isethi engu-1

I-Reactor
100kV/1 A 4sets

Isihlukanisi se-Capacitive 400kV

GDTF-520/260

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-260

Amandla (kVA)

520

Ububanzi bohlelo lokusebenza

I-110KV Circuit breaker kanye nebha yebhasi

110kV GIS

110kV (300 mm²) ikhebula 800m

35kv (300 mm²) ikhebula 3km

10kV (300 mm²) ikhebula 6km

I-110kv i-insulation Transformer egcwele

Ukucushwa okuyinhloko

25kW Umthombo wefrikhwensi eguquguqukayo 1 isethi

25kVA I-transformer ejabulisayo isethi engu-1

I-Reactor engu-65kV/2A 4sets

Isihlukanisi se-Capacitive 300kV

I-GDTF-500/500

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-500

Amandla (kVA)

500

Ububanzi bohlelo lokusebenza

220kV noma ngaphansi kwe-CT/PT

220kV noma ngaphansi kwehlathi

220kV noma ngaphansi Ama-Insulators, izixhumi

220kV noma ngaphansi Circuit breaker

220kV noma ngaphansi kwe-Insulation Instrument

Ukucushwa okuyinhloko

20kW Umthombo wefrikhwensi eguquguqukayo isethi engu-1

20kVA I-transformer ejabulisayo isethi engu-1

I-Reactor engu-125kV/1A 4sets

Isihlukanisi se-Capacitive 500kV

I-GDTF-600/600

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-600

Amandla (kVA)

600

Ububanzi bohlelo lokusebenza

110kV (300 mm²) ikhebula 800m

35kv (300 mm²) ikhebula 110m

35-220kV GIS, transformers, insulators

Ukucushwa okuyinhloko

30kW Umthombo wefrikhwensi eguquguqukayo isethi engu-1

30kVA I-transformer ejabulisayo isethi engu-1

I-Reactor 120kV/1A 5sets

Isihlukanisi se-Capacitive 600kV

I-GDTF-800/800

I-voltage yokufaka (V)

380

I-voltage ephumayo (kV)

0-800

Amandla (kVA)

800

Ububanzi bohlelo lokusebenza

110kV (300 mm²) ikhebula 800m

220kv (300 mm²) ikhebula 500m

35-500kV GIS, transformers, insulators

Ukucushwa okuyinhloko

40kW Umthombo wefrikhwensi eguquguqukayo isethi engu-1

40kVA I-transformer ejabulisayo isethi engu-1

I-Reactor engu-200kV/1A 4sets