Maphakathi noDisemba, amakhasimende akwaJiangsu athenga inqwaba yezinto zokuhlaziya amakhemikhali kawoyela enkampanini yethu.
Ngemva kokuqhathanisa abakhiqizi abaningi, ikhasimende lihlole amandla enkampani, futhi ekugcineni lanquma ukusayina inkontileka yokuthenga nenkampani yethu.Ngokushesha nje lapho inkontileka isisayiniwe, umnyango wokukhiqiza we-HV HIPOT waxhumanisa ngokushesha futhi wasebenza isikhathi esengeziwe ukuze ulethe izimpahla zekhwalithi ephezulu futhi uzihambise kumakhasimende.Izinto zokusebenza ezithengwe ikhasimende ngalesi sikhathi zihlanganisa:I-GDC-9560B isistimu yamandla ehlukanisa amafutha e-chromatograph analyzer.I-GD6100 i-transformer oil tan delta tester,GDSZ-402 othomathikhi uwoyela value umhloli, I-GDW-106 yokuhlola iphuzu lamazolo kawoyela, GDOT-80A insulating oil testernezinye izinto zokusebenza.
Isihlaziyi se-chromatographic sikawoyela esikhethekile sohlelo lwamandla kagesi uchungechunge olusebenza ngekhompyutha olunezinjongo eziningi eziningi lokuhlaziya i-chromatographic kawoyela ekhethekile yohlelo lwamandla kagesi.I-chromatograph kawoyela ekhethekile ye-GDC-9560B yohlelo lwamandla kagesi inohlelo lokulawula oluzenzakalelayo ngokugcwele.Ukunciphisa nokulungiswa kwe-zero kwesifunda sokulinganisa konke kulawulwa izinkinobho, futhi ukuzinza nokuthembeka kuphezulu.Isetshenziswa kabanzi kumandla kagesi, uphethiloli, imboni yamakhemikhali, insimbi, ukuvikelwa kwemvelo, ukudla, imithi, ezempilo kanye nezinkambu ezihlukahlukene zocwaningo lwesayensi.
I-GDC-9560B isistimu yamandla ehlukanisa amafutha e-chromatograph analyzer
Izici
Ukusebenza okulula: Iplathifomu yokusebenza yama-WINDOWS yamaShayina, isikhombimsebenzisi esigcwele sewindi lesiShayina, ukwaziswa kokusebenza kwesikhathi sangempela nosizo lwe-inthanethi, olulungele abasebenzisi ukufunda nokusebenzisa.
Isikhathi sangempela: ukutholwa kwedatha yesikhathi sangempela ngaphansi kwemvelo yangempela ye-WINDOWS, amasampula eziteshi ezimbili ngesikhathi esisodwa, isibonisi sesikhathi sangempela sesikhathi sokugcina esiphezulu se-chromatographic.
Ukunemba okuphezulu: ikhadi le-plug-in elingu-24-bit elinemba eliphezulu, ububanzi bokufaka: -1v~+1v.
Ukukhiqiza kabusha: 0.006%.
Vula ukuphathwa kwedatha: gcina ulwazi oluphelele lwemishini ehlobene nolwazi lwedatha yedatha yokuhlaziya, kulula ukuyengeza, ukulungisa, ukususa, nokufunda nokuthola ngokuthanda kwakho.Ifomethi yedatha evulekile ifanele ukwabelana ngedatha yabasebenzisi abaningi ukuze kube lula ukufinyelela kwamanye ama-software okulawulwa kwesizindalwazi kanye nezidingo zokubuyisa zeminyango yokuphatha.
Ukuxilongwa kwephutha okuzenzakalelayo: ngemva kokuhlaziywa, kuzobonisa ngokuzenzakalelayo ukuthi kudlula umkhawulo, kunikeze ukuxilongwa kwesilinganiso sesithathu esihlangabezana nezinga likazwelonke, umdwebo we-TD, umdwebo wokuhlushwa wengxenye kanye nezinye izindlela zokuxilongwa kwephutha.
Kalula ngekhwalithi: ithebula lokuhlonza inani eliphakeme lingahlelwa ngokuzenzakalelayo noma ngesandla.Isici sokulungisa sibalwa ngokuzenzakalelayo, futhi izilungiso eziningi zingalinganiswa.
Ukuhlonza isiqongo esivumelana nezimo namandla okucubungula: Iziqongo zeChromatographic zingakhonjwa, zisuswe futhi zilungiselwe ukusikwa okuyisisekelo ngokusetha amapharamitha nezinhlelo zesikhathi noma ukuzilungisa mathupha.Qinisekisa ukunemba kwemiphumela yokuhlaziya.
Umsebenzi wokuphrinta ovumelana nezimo: Nikeza imibiko yemiphumela ngefomethi engashintshi kanye nefomethi yesifanekiso esingokwezifiso.
Ukwamukela i-10/100M ethuthukisiwe yokuxhumana ye-Ethernet yokuxhumana, kanye nesitaki sephrothokholi ye-IP eyakhelwe ngaphakathi, ukuze ithuluzi likwazi ukubona kalula ukudluliswa kwedatha yebanga elide nge-LAN yangaphakathi yebhizinisi ne-inthanethi;isiza ukusungulwa kwelabhorethri futhi yenza ilabhorethri ibe lula Ukumiswa kusiza ukuphathwa kwedatha yokuhlaziya.
Idizayini yangaphakathi yethuluzi inezinqubo ezi-3 zokuxhuma ezizimele, ezingaxhunywa ekucutshungulweni kwendawo (indawo yelabhorethri), abaphathi bamayunithi (njengabaphathi besigaba sokuhlolwa kwekhwalithi, abaphathi bemishini yokukhiqiza, njll.), kanye nabaphathi abaphezulu (njengokuvikelwa kwemvelo i-bureau, i-technical supervision bureau, njll.), Kulula ngomphathi weyunithi nomphathi ophakeme ukuqapha ukusebenza kwethuluzi futhi ahlaziye imiphumela yedatha ngesikhathi sangempela.
Isiteshi sokusebenzela se-NetChromTM esingazikhethela sona singasekela umsebenzi wama-chromatograph amaningi ngesikhathi esisodwa, sibone ukucutshungulwa nokulawulwa kwedatha, senze ukuphathwa kwedokhumenti kube lula, futhi sinciphise ukutshalwa kwezimali kwelabhorethri yomsebenzisi kanye nezindleko zokusebenza ngezinga elikhulu kakhulu.
Uhlelo lunezinhlelo zokusebenza zesiShayina nesiNgisi, futhi abasebenzisi bangashintsha bodwa ngokwezidingo zabo.
Indawo yokulawula izinga lokushisa ingaqanjwa ngokukhululekile ngumsebenzisi, okuyinto elula kumsebenzisi ukuyisebenzisa.
Ithuluzi lamukela imodi yokusebenza ehambisanayo enamaprosesa amaningi ukuze lenze ithuluzi lizinze futhi lithembeke;ingahlangabezana nokuhlaziywa kwamasampuli ayinkimbinkimbi, futhi ingahlonyiswa ngezithonjana ezisebenza kahle kakhulu, njenge-FID, TCD, ECD, ne-FPD, futhi kungafakwa imitshina efika kwemine ngesikhathi esisodwa.Izithungatha ezengeziwe nazo zingasetshenziswa, okwenza kube lula ukuthenga nokufaka ezinye izithonjana ngemva kokuthengwa kwethuluzi.