I-GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester
I-GDCR3200C I-Double Clamp Multifunctional Earth Resistance Tester iklanywe ngokukhethekile futhi yakha ukulinganisa esizeni sokumelana nomhlaba, ukumelana nomhlabathi, amandla kagesi aphansi, amandla okuvuza komugqa ophansi, i-AC yamanje kanye ne-DC ukumelana.Ithuluzi lamukela ubuchwepheshe obuthuthukisiwe bokucubungula idijithali, ngendlela ye-2-wire, indlela ye-3-wire, indlela ye-4-wire, indlela yokukhetha, indlela yokubopha kabili nezinye izindlela zokulinganisa;Ngenisa ubuchwepheshe be-FFT (Fast Fourier Transform), ubuchwepheshe be-AFC (Automatic Frequency Control), obunekhono eliyingqayizivele lokulwa nokuphazamiseka kanye nokuvumelana nezimo zemvelo, ukuvumelana okuphindaphindiwe kokuhlolwa, ukuqinisekisa ukunemba okuphezulu, ukuzinza okuphezulu nokuthembeka okuphezulu ekukaleni isikhathi eside.Ithuluzi elisetshenzisiwe elisetshenzisiwe. idizayini enkulu yesigxivizo yamanje, ingabhekana nazo zonke izinhlobo zezidingo zokuhlola, ingakala inani lokumelana nesisekelo sosayizi omkhulu ophansi womthofu, ovumelana nezimo ukulinganisa inani lokumelana eliphansi lephoyinti elilodwa kanye nokugxilwa kwegridi kanye nazo zonke izinhlobo zesakhiwo esiyinkimbinkimbi sesisekelo, asikho isidingo sokunqamula noma yikuphi ukuxhuma okuhambisanayo kwesigxobo somhlaba lapho kulinganiswa uhlelo lwesisekelo oluhambisanayo, kuthuthukisa kakhulu ukusebenziseka kokulinganisa, ngoba ukuhlolwa kokusebenza kwesisekelo kunikeza isisombululo esiphelele.
I-GDCR3200C I-Double Clamp Multifunctional Earth Resistance Tester yakhiwe umshini wokusingathwa, ibamba lamanje(i-double clamp), izintambo zokuhlola, i-ground rod eyisizayo, isofthiwe yedatha nezintambo zokuxhumana nokunye.Isibonisi esikhulu se-LCD somshini wokusingathwa onokukhanya kwangemuva okumhlophe kanye nenkomba yegrafu yebha engabonakala kahle.Umhloli unomsebenzi wokulondoloza, umsebenzi wewashi, futhi ugcina ngokuzenzakalelayo amaqembu angu-2000 emiphumela yokuhlola equkethe usuku nesikhathi.Umhloli onokusebenza kokuxhumana kwe-Bluetooth osekela isistimu ye-Android.Ngemuva kokufakwa kwe-APP, ingahlola noma ifunde amarekhodi okuhlola kutheminali yeselula, ilethe isipiliyoni esisha.Umhloli uhlomisa isixhumi esibonakalayo se-USB, futhi idatha egciniwe ingalayishwa ku-PC ngesixhumi esibonakalayo se-USB.Isofthiwe yezokuxhumana ingakwazi ukubona imisebenzi yokufunda, ukubonisana, ukonga, ukubika nokuphrinta idatha yerekhodi yomlando.Isetshenziswa kakhulu emandleni, ezokuxhumana, kwi-meteorology, ezindaweni zikawoyela, ezokwakha, ekuvikelweni kombani nasezinsizeni zikagesi zezimboni.
●Idizayini ehlukile yokukhanya kwenkomba ye-jack, inkomba enembile yendawo ye-jack, gwema iphutha lokusebenza.
●Iphinikhodi yokukhetha umsebenzi wamagiya, kuboniswa izindlela ezahlukahlukene zokuhlola, okwenza ukusebenza kube lula futhi kusheshe.
●Umhloli unomsebenzi wokuxhumana we-Bluetooth futhi usekela isistimu ye-Android.Abasebenzisi bangasebenzisa itheminali yeselula ukuhlola ukusebenza noma ukufunda imiphumela yokuhlolwa equkethe usuku nesikhathi kalula kakhulu.
●Ikesi lensimbi lamukela ibhokisi lokuvikela elingangeni manzi, eliqinile, eliphephile futhi elihlala isikhathi eside ekulweni nokushayisana, ukulwa nokuwa nokungangeni kwamanzi (ibanga lokuvikela i-IP65), elifaneleka ngokukhethekile ukusetshenziswa kumasayithi okwakha angaphandle.
●Imitha ifakwe umthamo omkhulu we-lithium battery pack.Futhi nge-USB interface ukulayisha umsebenzi idatha.
Izimo eziyisisekelo nezimo zokusebenza
Ithonya Inani | Isimo Sesisekelo | Izimo zokusebenza | Phawula |
I-Ambient Temp | 23℃±1℃ | -10℃-40℃ | ---- |
Umswakamo we-Ambient | 40%-60% | <80% | ---- |
I-Voltage esebenzayo | 7.8V±0.1V | I-DC 7.8V±0.6V | ---- |
I-Axiliary Earth Resistance | <100Ω | <5 kΩ | |
Ukuphazamiseka kwe-Voltage | Kufanele ugweme | <20V | |
Ukuphazamiseka Kwamanje | Kufanele ugweme | <2A | |
Ibanga le-Electrode lapho kulinganiswa i-R | a>5d | a>5d | |
Ibanga le-Electrode lapho kulinganiswa ρ | a>20h | a>20h |
Ukucaciswa okujwayelekile
Umsebenzi | Kala ukumelana nesisekelo, ukumelana nenhlabathi;Ukumelana ne-DC, i-voltage yomhlaba, i-alternating current, ukuvuza kwamanje | |
Ukunikezwa kwamandla kagesi | I-DC 7.4V 2600mAh ibhethri le-lithium elishajekayo, eligcwele cishe i-8.4V | |
Ukukhanya kwangemuva | I-backlight yesikrini elawulekayo, ifanele izindawo ezifiphele | |
Indlela Yokukala | Ukumelana ne-DC | Indlela ye-DC yokumelana ne-2-wire |
Indlela ye-DC yokumelana ne-4-wire | ||
Ukumelana nomhlaba | Indlela yokumelana nomhlaba enezintambo ezi-2 | |
Indlela yokumelana nomhlaba enezintambo ezi-3 | ||
Indlela yokumelana nomhlaba enezintambo ezi-4 | ||
Ukumelana nomhlaba indlela eyodwa yocingo lwe-3-wire (indlela yokukhetha) | ||
Ukumelana nomhlaba indlela eyodwa yocingo lwe-4-wire (indlela yokukhetha) | ||
Ukuphikiswa komhlaba double clamp indlela | ||
Ukumelana nomhlabathi (indlela ye-Wenner) | ||
Umhlaba wamanje | Isilinganiso samanje sokubopha | |
I-voltage yomhlaba | Ukulungiswa okumaphakathi | |
Hlola i-Voltage Wave | Sine wave | |
Test Frequency | 128Hz/111Hz/105Hz/94Hz(AFC) | |
Ukuhlola Kwesikhashana Esifushane | I-AC 250mA ubuningi | |
Isivivinyo Esivulekile Sesekhethi Yamanje | I-AC 40V ubuningi | |
Electrode Distance Range | 1m-100m | |
Imodi yokubonisa | Isibonisi se-LCD esikhulu sedijithali esingu-4, esinokukhanya kwangemuva kwesikrini | |
Inkomba Yokulinganisa | Ngesikhathi sokulinganisa, inkomba ye-flash ye-LED, isibonisi sokubala wehla se-LCD | |
I-LCD Frame Dimension | 128mm×75mm | |
Indawo yokubonisa i-LCD | 124mm×67mm | |
I-Instrument Dimension | 280mm(L) X 260mm(W) X 160mm(H) | |
Usayizi we-CT | 223mm X 120mm X 39mm | |
Intambo Yokuhlola | Izintambo ezi-4: ngayinye ibomvu 20m, emnyama 20m, ephuzi 10m, futhi eluhlaza 10m | |
I-Simple Test Wire | 2 izintambo: ngayinye ebomvu 1.6m futhi emnyama 1.6m | |
I-Axiliary Grounding Rod | 4PCS: Φ10mm X150mm | |
I-Clamp Yamanje | 2PCS :1 ipulaki elimnyama okwesibhakabhaka kanye nepulaki eli-1 elibomvu-elimnyama | |
I-Clamp Caliber | Φ70mm | |
Clamp lead Wire | 2m | |
Isilinganiso sokulinganisa | I-AC yamanje: cishe izikhathi ezi-2/ngesekhondi | |
I-Earth Voltage: cishe izikhathi ezi-2/ngesekhondi | ||
Ukumelana nomhlaba: cishe imizuzwana engu-7/isikhathi | ||
Izikhathi Zokukala | Izikhathi ezingaphezu kuka-5000 (Ukuhlolwa kwesiyingi esifushane, isikhathi sokuphumula kufanele sibe okungenani imizuzwana engama-30) | |
I-Voltage yomugqa | Isilinganiso esingaphansi kwe-AC 600V | |
Isixhumanisi Esibonakalayo | Imojuli ye-Bluetooth, isixhumi esibonakalayo se-USB, idatha yokulondoloza ingalayishwa kukhompuyutha, igcinwe noma iphrintwe. | |
Intambo Yokuxhumana | Intambo yokuxhumana ye-USB x1pcs, enobude obungu-1.5m | |
Ukubamba Idatha | Umsebenzi wokubamba idatha: "BAMBA" isibonisi sophawu | |
Isitoreji Sedatha | Amaqembu angu-2000, inkomba yesitoreji ye-“MEM”, isitoreji sesibonisi sophawu "OKUGCWELE" sigcwele | |
Ukufinyelela Idatha | Umsebenzi wokufunda idatha:"FUNDA" isibonisi sophawu | |
Isibonisi Esichichimayo | Yeqa umsebenzi wokuchichima kobubanzi bokulinganisa: "OL"isibonisi sophawu | |
Inkomba yamanje ephansi ye-clamp yamanje | Ukulinganisa ngendlela yokukhetha noma i-clamp ephindwe kabili, isignali yamanje etholwe yi-CT2 ingaphansi kuka-0.5mA, izobonisa "", futhi kufanele ihlole isiqondiso sokuphoqa kwe-CT2 i-clamp yamanje | |
Ukuhlolwa kokuphazanyiswa | Ukuhlonza okuzenzakalelayo kwamasignali okuphazamisa, inkomba yophawu lwe-“NOISE” lapho i-voltage yokuphazamiseka ingaphezu kuka-5V | |
Isivivinyo Sokugxilisa Esisizayo | Ngomsebenzi wokuhlola wokuqina osizayo, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
Umsebenzi we-alamu | Inani lokulinganisa lidlula inani lokusetha i-alamu, lizokwenza umsindo we-alamu othi "Toot-toot-toot". | |
Ibhethri Voltage | Ngenkathi amandla ebhethri ehla aze afike cishe ku-7.2V±0.1V, izobonisa uphawu oluphansi lwe-voltage yebhethri, futhi ikhumbuza ukushintshwa kwebhethri | |
Ukuvala shaqa okuzenzakalelayo | Vala ngokuzenzakalelayo ngemva kwemizuzu engu-15 yokukhanyisa amandla | |
Ukusebenza Kwamanje | I-Backlight: 25mA Max (ukusetshenziswa kwamandla we-backlight kuphela) | |
Okubekwe eceleni:25mA Max(Isibani sangemuva sivaliwe ngemva kokukhanyisa) | ||
Isilinganiso: I-150mA Max (I-Backlight ivaliwe) | ||
Isisindo | Isihloli: 2290g | |
Isisindo samanje: 1100g(2pcs) | ||
Isisindo esiphelele: 6800g(faka zonke izesekeli) | ||
Amazinga Okushisa Okusebenzayo Nomswakama | -10℃-40℃, ngaphansi kuka-80%rh | |
Izinga lokushisa lesitoreji nomswakama | -20℃-60℃, ngaphansi kuka-70%rh | |
Izinga Lokuvikela | IP65(vala ikesi) | |
Ukuvikelwa kokulayisha ngokweqile | Linganisa ukumelana nomhlaba: phakathi kokuxhumana ngakunye kwe-C(H)-E,P(S)-ES, AC 280V/3 imizuzwana | |
I-Insulation Resistance | Ngaphezu kuka-20MΩ(phakathi kwesekhethi nangaphandle igobolondo ngu-500V) | |
Ukumelana ne-Voltage | I-AC 3700V/rms.(Phakathi kwesekhethi nangaphandle) | |
Izici ze-Electromagnetic | I-IEC61326(EMC) | |
Uhlobo Lokuvikela | I-IEC61010-1(CAT Ⅲ 300V,I-CAT IV 150V,Ukungcola 2); I-IEC61010-031; I-IEC61557-1 (Ukumelana nomhlaba); I-IEC61557-5(Ukumelana nomhlabathi); I-JJG 366-2004(Imitha yokumelana nokuphansi) I-JJG 1054-2009(Imitha yokumelana ne-Clamp grounding) |