I-GLF-314 SF6 Umtshina wokuvuza wesithombe se-infrared wegesi
● Ukuboniswa okunembile kwesimo sokuvuza kwegesi ngesikhathi sangempela.
● Imodi ye-infrared ethuthukisiwe ukuze kutholwe ukuvuza kwegesi okuncane kakhulu.
● Isistimu yokusebenza eshumekiwe, idizayini ye-UI efana neselula nethebhulethi yenza kube lula kubasebenzisi ukuthi baqalise.
● I-USB, i-WiFi, i-HDMI izindlela zokudlulisa idatha eziningi.
● Isibonisi se-LCD esishintshashintshayo sokulungiswa okuphezulu.
● Isitholi sokubonwayo esinokucaca okuphezulu esine-engeli elungisekayo yokukhanya okukhanyayo.
● Idizayini engasindi, eqinile.
● Idizayini ye-ergonomic yokulwa nokukhathala.
● Umsingathi wesithombe esishisayo
● I-adaptha yamandla
● Amabhethri namashaja aphindekayo e-Lithium-Ion
● Ikhebula le-USB
● Ikhebuli yevidiyo ye-HDMI
●Imemori khadi ye-32G TF nesifundi sekhadi
● Imanuwali yomsebenzisi
● Ibhokisi lokupakisha
N0. | Izinto | Imininingwane | |
1 | Umtshina kanye namapharamitha okubona | Uhlobo lomtshina | Akupholisiweii-nfrareddama-etectors |
2 | Ukulungiswa kwe-infrared | 384×288 | |
3 | Isikhala samaphikseli | 25μm | |
4 | Hlunga ubude bebanga lokuphendula kwe-bandpass | 7μm–8.5μm,9.5μm -12μm | |
5 | Ukuzwela kwe-Thermal (NETD) | <0.1℃@30℃ | |
6 | Igesi elibonakalayo | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Ilensi ye-infrared | Ilensi evamile(21.7°±2°)× (16.4°±2°) | |
8 | Ukugxila kwe-infrared | Imanuwali & ngokuzenzakalela | |
9 | Ukuboniswa kwesithombe | Ukusondeza kwedijithali | Izikhathi ezi-1 kuye kweziyi-10 zokusondeza kwedijithali okuqhubekayo |
10 | Izinga lozimele wesithombe | 50Hz±1Hz | |
11 | Ukulungiswa kwesibonisi | 1024×600 | |
12 | Bonisa isikrini | 5-intshi touch screen, isinqumo 1024×600 | |
13 | Isitholi sokubuka | Isibonisi esinokulungiswa okuphezulu kwe-OLED, amaphikseli angu-1024 x 600 | |
14 | Imodi yokubonisa | Imodi ye-infrared. Imodi yokukhulisa igesi. Imodi yokulinganisa izinga lokushisa le-infrared. Imodi yokukhanya ebonakalayo. Imodi yesithombe-esithombeni. Imodi ye-Fusion; | |
15 | Ukulungiswa kwesithombe | Ukukhanya okuzenzakalelayo kanye nokulungiswa kokuqhathanisa | |
16 | Iphalethi | Izinhlobo ezingu-10 + 1 okuchazwe umsebenzisi | |
17 | Ikhamera yedijithali | Inkambu yokubuka ihambisana nelensi ye-infrared | |
18 | Izibani ze-LED | Yebo | |
19 | Ukulinganisa izinga lokushisa nokuhlaziya | Ibanga lokulinganisa izinga lokushisa | Igiya eli-1:-20 — 150°C 2 igiya:100 — 650°C |
20 | Ukunemba | ±3℃or ±3%(Thatha inani elikhulu, izinga lokushisa le-ambient lingu-15°C kuya ku-35°C) | |
21 | Isilinganiso sezinga lokushisa elimaphakathi | Yebo | |
22 | Isilinganiso sokushisa sephoyinti elinyakazayo | Isekela amaphuzu angu-10 | |
23 | Isilinganiso sezinga lokushisa lendawo ephathekayo | Isekela imibuthano eyi-10 nonxande abayi-10 | |
24 | Isilinganiso sokushisa somugqa onyakazayo | Isekela imigqa eyi-10 | |
25 | Ukuma kwephoyinti lokushisa okuphezulu nokuphansi | Sekela ukuma kwephoyinti lokushisa kwesikrini esigcwele esiphezulu nesiphansi kanye nokuma kwephoyinti lokushisa eliphezulu neliphansi endaweni | |
26 | Ukusetha ngaphambilini kokulinganisa | Asikho isilinganiso, indawo emaphakathi, izinga lokushisa eliphakeme kakhulu, izinga lokushisa elincane, izinga lokushisa elimaphakathi | |
27 | I-alamu yezinga lokushisa | Ama-alamu ombala (imigqa ye-isothermal): ngenhla/ngezansi kwamazinga okushisa acacisiwe, phakathi kwamazinga okushisa acacisiwe. Ama-alamu omsebenzi wokulinganisa: Ama-alamu azwakalayo (ngenhla/ngezansi/phakathi kwamazinga okushisa acacisiwe). | |
28 | Ukulungiswa kwenani elilinganiselwe | I-Emissivity (0.01 ukuya ku-1.0 okukhethekayo), izinga lokushisa elibonisiwe, umswakama ohlobene, izinga lokushisa lomoya, ibanga eliqondiwe, isinxephezelo sewindi le-ir langaphandle | |
29 | Ukugcinwa kwedethi | Isitoreji esimaphakathi | Imemori khadi ye-TF ekhiphekayo |
30 | Thatha izithombe njalo | Imizuzwana emi-3 ukuya emahoreni angama-24 | |
31 | Ukuhlaziywa kwesithombe se-radiometric esigcwele somdabu | Izithombe ezishisayo ze-radiometric ezilondoloziwe zingahlelwa futhi zihlaziywe kukhamera | |
32 | Ifomethi yefayela lesithombe | Izithombe ezijwayelekile ze-JPEG, okuhlanganisa izithombe zedijithali nedatha egcwele ye-radiometric | |
33 | Ukuqoshwa kwevidiyo ye-infrared ye-Radiometric | Ukuqoshwa kwamavidiyo emisebe yesikhathi sangempela, *.ifayela elingahluziwe ligcinwa ekhadini le-TF | |
34 | Ukurekhodwa kwevidiyo ye-infrared engeyona imisebe | *.avi ifayela levidiyo, gcina ekhadini le-TF | |
35 | Isichasiselo sesithombe | Izwi: imizuzwana engama-60, egcinwe nesithombe Umbhalo: Engeza ithebula, khetha phakathi kwezifanekiso ezichazwe ngaphambilini | |
36 | Ukubuka kwesibonisi esikude | Buka ukusakazwa kwamavidiyo ngesikhathi sangempela nge-Wi-Fiuxhumano. Xhuma ukuze ubonise nge-HDMI isixhumi esibonakalayo esinencazelo ephezulu; | |
37 | Ukulawulwa kokusebenza kwesilawuli kude | Xhuma kusilawuli sesofthiwe esizinikele nge-Wi-Fi; | |
38 | Ukuxhumana nama-peripherals | esibonakalayo | I-USB 2.0, I-Wi-Fi, I-HDMI |
39 | I-WIFI | Yebo | |
40 | Umsindo | Imakrofoni nesipika sesichasiselo sezwi sesithombe nokuqoshwa kwevidiyo | |
41 | laser pointer | Yebo | |
42 | I-GPS | Sekela ukuma kwesathelayithi, imininingwane yendawo ingagcinwa esithombeni | |
43 | Ukunikezwa kwamandla kagesi | Uhlobo lwebhethri | Ibhethri ye-lithium electronic eshajwayo |
44 | I-voltage yebhethri | 7.4v | |
45 | Isikhathi sokusebenza esiqhubekayo | Hhayi ngaphansi kwamahora angu-4 ekamelweni lokushisa | |
46 | Ukunikezwa kwamandla kwangaphandle | Sekela ugesi wangaphandle we-dc12v | |
47 | Ukuphathwa kwamandla | Ukuvala shaqa okuzenzakalelayo noma isikrini esizenzakalelayo sivaliwe, isikhathi singakhethwa kusukela kokungakaze, 5min, 10min, 30min | |
48 | Ukuvumelana nezimo zemvelo
| Izinga lokushisa lokusebenza | -20-+50 ℃ |
49 | Izinga lokushisa lesitoreji | -40-+70 ℃ | |
55 | Izici ezingokomzimba | Isisindo (ngaphandle kwebhethri) | ≤ 1.8 kg |
56 | Ubukhulu (H*W*L) | ≤185 mm × 148 mm × 155 mm (okuhlanganisa ilensi evamile) | |
57 | Isisekelo se-Tripod Mount | Okujwayelekile,1/4"-20 |
● Ukuboniswa okunembile kwesimo sokuvuza kwegesi ngesikhathi sangempela.
● Imodi ye-infrared ethuthukisiwe ukuze kutholwe ukuvuza kwegesi okuncane kakhulu.
● Isistimu yokusebenza eshumekiwe, idizayini ye-UI efana neselula nethebhulethi yenza kube lula kubasebenzisi ukuthi baqalise.
● I-USB, i-WiFi, i-HDMI izindlela zokudlulisa idatha eziningi.
● Isibonisi se-LCD esishintshashintshayo sokulungiswa okuphezulu.
● Isitholi sokubonwayo esinokucaca okuphezulu esine-engeli elungisekayo yokukhanya okukhanyayo.
● Idizayini engasindi, eqinile.
● Idizayini ye-ergonomic yokulwa nokukhathala.
● Umsingathi wesithombe esishisayo
●I-adaptha yamandla
● Amabhethri namashaja angatshajwa kabusha e-Lithium-Ion
●Ikhebula le-USB
●Ikhebuli yevidiyo ye-HDMI
●Imemori khadi ye-32G TF nesifundi sekhadi
●Imanuwali yomsebenzisi
●Ibhokisi lokupakisha
N0. | Izinto | Imininingwane | |
1 | Umtshina kanye namapharamitha okubona | Uhlobo lomtshina | Akupholisiweii-nfrareddama-etectors |
2 | Ukulungiswa kwe-infrared | 384×288 | |
3 | Isikhala samaphikseli | 25μm | |
4 | Hlunga ubude bebanga lokuphendula kwe-bandpass | 7μm–8.5μm,9.5μm -12μm | |
5 | Ukuzwela kwe-Thermal (NETD) | <0.1℃@30℃ | |
6 | Igesi elibonakalayo | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Ilensi ye-infrared | Ilensi evamile(21.7°±2°)× (16.4°±2°) | |
8 | Ukugxila kwe-infrared | Imanuwali & ngokuzenzakalela | |
9 | Ukuboniswa kwesithombe | Ukusondeza kwedijithali | Izikhathi ezi-1 kuye kweziyi-10 zokusondeza kwedijithali okuqhubekayo |
10 | Izinga lozimele wesithombe | 50Hz±1Hz | |
11 | Ukulungiswa kwesibonisi | 1024×600 | |
12 | Bonisa isikrini | 5-intshi touch screen, isinqumo 1024×600 | |
13 | Isitholi sokubuka | Isibonisi esinokulungiswa okuphezulu kwe-OLED, amaphikseli angu-1024 x 600 | |
14 | Imodi yokubonisa | Imodi ye-infrared. Imodi yokukhulisa igesi. Imodi yokulinganisa izinga lokushisa le-infrared. Imodi yokukhanya ebonakalayo. Imodi yesithombe-esithombeni. Imodi ye-Fusion; | |
15 | Ukulungiswa kwesithombe | Ukukhanya okuzenzakalelayo kanye nokulungiswa kokuqhathanisa | |
16 | Iphalethi | Izinhlobo ezingu-10 + 1 okuchazwe umsebenzisi | |
17 | Ikhamera yedijithali | Inkambu yokubuka ihambisana nelensi ye-infrared | |
18 | Izibani ze-LED | Yebo | |
19 | Ukulinganisa izinga lokushisa nokuhlaziya | Ibanga lokulinganisa izinga lokushisa | Igiya eli-1:-20 — 150°C 2 igiya:100 — 650°C |
20 | Ukunemba | ±3℃or ±3%(Thatha inani elikhulu, izinga lokushisa le-ambient lingu-15°C kuya ku-35°C) | |
21 | Isilinganiso sezinga lokushisa elimaphakathi | Yebo | |
22 | Isilinganiso sokushisa sephoyinti elinyakazayo | Isekela amaphuzu angu-10 | |
23 | Isilinganiso sezinga lokushisa lendawo ephathekayo | Isekela imibuthano eyi-10 nonxande abayi-10 | |
24 | Isilinganiso sokushisa somugqa onyakazayo | Isekela imigqa eyi-10 | |
25 | Ukuma kwephoyinti lokushisa okuphezulu nokuphansi | Sekela ukuma kwephoyinti lokushisa kwesikrini esigcwele esiphezulu nesiphansi kanye nokuma kwephoyinti lokushisa eliphezulu neliphansi endaweni | |
26 | Ukusetha ngaphambilini kokulinganisa | Asikho isilinganiso, indawo emaphakathi, izinga lokushisa eliphakeme kakhulu, izinga lokushisa elincane, izinga lokushisa elimaphakathi | |
27 | I-alamu yezinga lokushisa | Ama-alamu ombala (imigqa ye-isothermal): ngenhla/ngezansi kwamazinga okushisa acacisiwe, phakathi kwamazinga okushisa acacisiwe. Ama-alamu omsebenzi wokulinganisa: Ama-alamu azwakalayo (ngenhla/ngezansi/phakathi kwamazinga okushisa acacisiwe). | |
28 | Ukulungiswa kwenani elilinganiselwe | I-Emissivity (0.01 ukuya ku-1.0 okukhethekayo), izinga lokushisa elibonisiwe, umswakama ohlobene, izinga lokushisa lomoya, ibanga eliqondiwe, isinxephezelo sewindi le-ir langaphandle | |
29 | Ukugcinwa kwedethi | Isitoreji esimaphakathi | Imemori khadi ye-TF ekhiphekayo |
30 | Thatha izithombe njalo | Imizuzwana emi-3 ukuya emahoreni angama-24 | |
31 | Ukuhlaziywa kwesithombe se-radiometric esigcwele somdabu | Izithombe ezishisayo ze-radiometric ezilondoloziwe zingahlelwa futhi zihlaziywe kukhamera | |
32 | Ifomethi yefayela lesithombe | Izithombe ezijwayelekile ze-JPEG, okuhlanganisa izithombe zedijithali nedatha egcwele ye-radiometric | |
33 | Ukuqoshwa kwevidiyo ye-infrared ye-Radiometric | Ukuqoshwa kwamavidiyo emisebe yesikhathi sangempela, *.ifayela elingahluziwe ligcinwa ekhadini le-TF | |
34 | Ukurekhodwa kwevidiyo ye-infrared engeyona imisebe | *.avi ifayela levidiyo, gcina ekhadini le-TF | |
35 | Isichasiselo sesithombe | Izwi: imizuzwana engama-60, egcinwe nesithombe Umbhalo: Engeza ithebula, khetha phakathi kwezifanekiso ezichazwe ngaphambilini | |
36 | Ukubuka kwesibonisi esikude | Buka ukusakazwa kwamavidiyo ngesikhathi sangempela nge-Wi-Fiuxhumano. Xhuma ukuze ubonise nge-HDMI isixhumi esibonakalayo esinencazelo ephezulu; | |
37 | Ukulawulwa kokusebenza kwesilawuli kude | Xhuma kusilawuli sesofthiwe esizinikele nge-Wi-Fi; | |
38 | Ukuxhumana nama-peripherals | esibonakalayo | I-USB 2.0, I-Wi-Fi, I-HDMI |
39 | I-WIFI | Yebo | |
40 | Umsindo | Imakrofoni nesipika sesichasiselo sezwi sesithombe nokuqoshwa kwevidiyo | |
41 | laser pointer | Yebo | |
42 | I-GPS | Sekela ukuma kwesathelayithi, imininingwane yendawo ingagcinwa esithombeni | |
43 | Ukunikezwa kwamandla kagesi | Uhlobo lwebhethri | Ibhethri ye-lithium electronic eshajwayo |
44 | I-voltage yebhethri | 7.4v | |
45 | Isikhathi sokusebenza esiqhubekayo | Hhayi ngaphansi kwamahora angu-4 ekamelweni lokushisa | |
46 | Ukunikezwa kwamandla kwangaphandle | Sekela ugesi wangaphandle we-dc12v | |
47 | Ukuphathwa kwamandla | Ukuvala shaqa okuzenzakalelayo noma isikrini esizenzakalelayo sivaliwe, isikhathi singakhethwa kusukela kokungakaze, 5min, 10min, 30min | |
48 | Ukuvumelana nezimo zemvelo
| Izinga lokushisa lokusebenza | -20-+50 ℃ |
49 | Izinga lokushisa lesitoreji | -40-+70 ℃ | |
55 | Izici ezingokomzimba | Isisindo (ngaphandle kwebhethri) | ≤ 1.8 kg |
56 | Ubukhulu (H*W*L) | ≤185 mm × 148 mm × 155 mm (okuhlanganisa ilensi evamile) | |
57 | Isisekelo se-Tripod Mount | Okujwayelekile,1/4"-20 |