I-GDJB-6000M Uhlelo Lokuhlola I-Smart Substation Relay Protection
I-GDJB-6000M I-Smart Substation Relay Test System iyisizukulwane esisha somhloli ohlakaniphile wokuvikela ukudluliselwa okuklanywe ngokuya ngokuthi "Izicaciso Zobuchwepheshe Zokuvikela I-Smart Substation Relay" kanye "Nemihlahlandlela Yobuchwepheshe Yesiteshi Esingaphansi Esihlakaniphile".Ngeke nje ibone ukuhlolwa okuphelele kokusebenza kwedivayisi yokuvikela idijithali (IEC61850, isiteshi sedijithali esihlakaniphile), kodwa futhi yenze ukuhlolwa okugcwele kokusebenza kudivayisi yokuvikela yendabuko (isiteshi esivamile).
I-GDJB-6000M iwumkhiqizo omusha ophathekayo othuthukiswe ngokuzimele ngokusetshenziswa kobuchwepheshe obufana nezinhlelo zokusebenza zesikhathi sangempela ezishumekiwe, amaphrosesa ashumekiwe asebenza kahle kakhulu, namadivayisi anengqondo amakhulu, ahlanganiswe nezimo zenkundla yamandla kanye nolwazi oluningi lwabasebenzisi bamandla.Isebenza kabanzi ezimbonini zikagesi, iziteshi ezingaphansi, abakhiqizi bemishini, amabhizinisi nezikhungo, kanye nezinye izikhungo zocwaningo ezidinga ukwenza ukuhlolwa kokuvikela ukudluliselwa noma ukuhlola.
I-GDJB-6000M yamukela uhlelo lokuphatha lobunjiniyela ukuze ilawule ukuhlolwa;ukuphathwa kwephrojekthi kusebenzisa imodeli enezendlalelo ezintathu zemishini yokuvikela, uhlobo lokuvikela, nendawo yokuhlola ukuze kulawuleke ukuhlolwa.Isakhiwo sicace kakhulu;Isekela okukhiphayo kwe-analog, futhi ingakwazi ngesikhathi esisodwa ukukhipha inani le-analog futhi ithumele futhi yamukele imilayezo ye-GOOSE;Inikeza izindlela eziningi zokumisa imilayezo ye-SV ne-GOOSE, okuhlanganisa izilungiselelo ezenziwa ngesandla, ukutholwa kwenethiwekhi, nokungenisa amafayela e-SCL;Umlayezo wedijithali obonakalayo unokucushwa okuvumelana nezimo kakhulu kwe-transceiver, engathumela imiyalezo eminingi ye-SV ne-GOOSE ngembobo yokubona engu-1, futhi imilayezo efanayo ye-SV ne-GOOSE ingathunyelwa ngezimbobo eziningi zokubuka.
I-DL/T 860 Series Standard "Inethiwekhi Yokuxhumana Yesiteshi Nesistimu"
I-DL/T 624-2010 "Izimo Zobuchwepheshe Zokuvikela I-Relay Isisetshenziswa Sokuhlola Esisekelwe Kwikhompyutha"
I-GBT 7261-2008 "Indlela Yokuhlola Eyisisekelo Yokuvikela I-Relay kanye Namadivayisi Azenzakalelayo Wokuphepha"
I-IEC 60255-24:2001 "Ama-relay kagesi - Ingxenye 24: Ifomethi evamile yokushintshisana kwedatha yesikhashana (COMTRADE) yezinhlelo zamandla"
●I-Smart Test Module
Ukuhlela isifanekiso sokuhlola okuhlakaniphile kuyasekelwa.Izinto zokuhlola zingangezwa ngokungahleliwe phakathi nenqubo yokuhlola futhi zilondolozwe njengamafayela ephrojekthi okuhlola asebenziseka kabusha ukuze kuthuthukiswe ukusebenza kahle kokuhlola esigabeni sokugcina sokuhlola nokuqedwa.Imisebenzi yesofthiwe eqinile.Isikhathi sangempela sokubonisa i-waveform, max.Isiqongo nendawo.Isofthiwe ingabheka futhi ihlaziye i-waveform yesigaba esithile.IWindows ingasondezwa futhi ikhishwe.Idatha yesigaba esisodwa ingahlaziywa futhi okuqukethwe kwe-spectrum ye-waveform yokukhishwa kungahlaziywa.
●Ukuhlola okuzenzakalelayo
Ngokuvikelwa kwesayithi kanye nomsebenzi wokuhlola ozenzakalelayo wokuvikelwa kwedijithali, zonke izinto zokuhlola zedivayisi eyodwa yokuvikela zingaqedwa ngokhiye owodwa.Idatha yokuhlola kanye nefomu lokuphuma kwesikhashana lokukhipha kungalondolozwa ngokuzenzakalelayo noma ngesandla.
●Okukhiphayo kwedijithali/analogi
Ingahlola iyunithi yokuhlanganisa, ukuvikela, ukulinganisa nokulawula amadivayisi, namatheminali ahlakaniphile eziteshi ezingaphansi zedijithali, futhi ingahlola amadivayisi afana nokuvikelwa kwe-analogi neyunithi ye-transformer.
●Ukukhishwa ngesikhathi esisodwa kwenani le-analog nedijithali
Isekela ukukhishwa kwe-analog ngasikhathi sinye kanye nokuthumela nokwamukela umlayezo we-GOOSE.
● Izindlela zokuskena eziningi
Isekela i-amplitude, isigaba, imvamisa, i-impedance, i-vector, ukulandelana, namandla enziwa ngokuhlolwa okwenziwa ngesandla noma okuzenzakalelayo, futhi isekela ukuhlolwa kokushintsha okuzenzakalelayo ngokuya kwendlela yokugreda, ukushelela kanye nokuhlanganiswa.
● Ukuphepha ne-alamu
Ngokuvikelwa kokushisisa ngokweqile nokwamanje kakhulu, umthombo wamanje unokuvikela kwesekhethi evulekile nomsebenzi we-alamu, futhi umthombo wamandla kagesi unomsebenzi wokuvikela ogcwele kakhulu nomsebenzi wokuvikela isifunda esifushane.
● Isibonisi sesithombe setheminali ebonakalayo
Sekela umsebenzi wokubonisa umfanekiso wesiphetho esibonakalayo, ukugeleza kwedatha kucacile.
●Thumela futhi wamukele imilayezo ngesikhathi esifanayo
Sekela i-IEC61850-9-1, IEC61850-9-2 kanye ne-GOOSE optical digital message output.Isiginali ye-GOOSE ingathunyelwa futhi yamukelwe ngokuzimela, futhi ingathumela futhi yamukelwe ngesixhumi esibonakalayo se-Ethernet esine-IEC 61850-9-2.
● I-FT3/I-FT3 Enwetshiwe
Isekela i-FT3, i-FT3 enwetshiwe kanye ne-DL/T 282 ephumayo yomlayezo, futhi isekela 2M/4M/6M/8M/10M isilinganiso sombhalo wekhodi we-UART kanye nombhalo wekhodi we-Manchester ongu-5M/10M/20M.
● Ukuhlolwa okungavamile
Ngomsebenzi wokungajwayelekile womlayezo we-analog, ingakwazi ukulingisa okungavamile ngekhwalithi, ukuthumela i-jitter yefrikhwensi, ukubambezeleka okudidayo, ukulahleka kwephakethe, ukuphuma esinyathelweni, ukweqa inombolo ye-serial, imodi yokunakekela, uguquko olubonakalayo lwesimo nokunye ukuhlola.
● Ukudlala iphutha
Isekela ukulingisa iphutha kanye nomsebenzi wokudlala idatha wefomethi ye-COMTRADE.
● Isevisi ye-MMS
Ngomsebenzi wokufunda nokubhala we-MMS, ingafunda futhi ibhale izilungiselelo zemishini ye-IED ehlakaniphile nolunye ulwazi lokumisa.
● Ukuvumelanisa isikhathi nokunikeza isikhathi
Ngomsebenzi wokucupha ovumelanisiwe, usekelo lokufinyelela okuqondile ku-antenna ye-GPS/BD ngesikhathi sokuvumelanisa, futhi isekela imodi yesikhathi ye-IRIG-B, PPS kanye ne-PTP 1588 futhi ingasekela ukuphuma kwangaphandle kwe-IRIG-B, PPS kanye ne-PTP 1588 enikeza isignali isikhathi.
● Okokufaka kanambambili othintana kanzima kanye nokuphumayo kanambambili
Amanani okokufaka ayasebenza futhi othintana nabo abaguquguqukayo abakhona, futhi uhlobo lokufakwayo ne-voltage yokufaka zibonwa ngokuzenzakalelayo.Amashaneli ahlukanisiwe komunye nomunye, futhi uxhumano lwe-polarity luhlehla ngokwaziswa kwe-alamu.
●Ukwamukela nokuhlaziya umlayezo
Ngomsebenzi wokwamukela nokuhlaziya umlayezo, umlayezo owamukelwe ungavulwa nge-ZHNPA ukuze uhlaziywe noma uthunyelwe.
●Imodi yefiber eyodwa
Imbobo yokubona isekela ukudluliswa kwefayibha eyodwa kanye nokwamukela kwefayibha eyodwa futhi isekela ukuhlolwa kwamandla okubona.
●Isignali encane ye-analog
Ifakwe isibonisi esibonakalayo esincane se-analog, isekela indlela engu-12 yokufaka isignali encane ye-analog, ingakala -7V~ 7V AC voltage, isekele indlela engu-12 yokuphuma kwesignali encane ye-analog, futhi ingakhipha -7V~ 7V AC voltage.
●Ukusebenza kokuthinta
Ifakwe isibonisi esinokulungiswa okuphezulu okungu-10.4 inch esisekela ukusebenza kokuthinta.
●Ukuxhumeka okungenantambo
Nikeza umsebenzi wokuhlola wesilawuli kude, ngemojuli ye-WiFi, esebenziseka kalula.
Umthombo wamandla kagesi we-AC | Ububanzi: 6×120 V, 120V/60VA ngendlela Ukunemba: ±10mV ku-0.2~2V;±0.2% ku-2V~120V Ukulungiswa: 1mV |
Okukhiphayo komthombo wamanje we-AC | Ububanzi: 6×30A, 30A/150VA ngendlela Ukunemba: ±10mA ku-0~500mA;±0.2% ku-500mA~30A Ukulungiswa: 1mA |
Isigaba sokuphumayo | Ibanga: 0~360° Ukunemba: ±0.1° Ukulungiswa: 0.1° |
Imvamisa yokuphumayo | Ibanga: 0 ~ 1000Hz Ukunemba:<±0.001Hz (0~65Hz) <±0.01Hz(65~450Hz) <±0.02Hz (450~1000Hz) Ukulungiswa: 0.001 Hz |
Umthombo wamandla kagesi we-DC | Ibanga: 6 indlela, indlela ngayinye 0~130V/60VA Ukunemba: 0.2% |
Umthombo wamanje we-DC ophumayo | Ibanga: 6 indlela, indlela ngayinye 0~20A/100VA Ukunemba: 0.2% |
I-IEC 61850 isikhombikubona sokuxhumana | Inombolo yezimbobo: amapheya ayi-6 ayi-100M eguquguqukayo;2 amapheya kukhona 100/1000M adaptive Uhlobo lwesixhumi esibonakalayo: LC Ubude begagasi: 1310nm |
I-IEC 60044 isikhombikubona sokuxhumana | Inombolo yezimbobo: 6 izimbobo zokudlulisa, 2 zamukela izimbobo Uhlobo lwesixhumi esibonakalayo: ST Ubude begagasi: 850nm |
Ukuvumelanisa esibonakalayo | Ubuningi: 1 * GPS / BD ANT;2*IRIG-B/PPS isignali yokubona-I-1 yesikhathi, i-1 yokunikeza isikhathi;2 amapheya* IRIG-B/PPS amasignali kagesi-1 ipheya yesikhathi, ipheya eli-1 lokupha isikhathi;1 ipheya* IEEE 1588; Uhlobo lwesixhumi esibonakalayo: GPS/BD ANT, IRIG-B/PPS isignali yokubona;I-IRIG-B/PPS isignali kagesi;IEEE 1588 |
Ukulinganisa isikhathi | Ibanga:10ms~9999.999s Ukunemba: 1ms |
Shintsha okokufaka | Ubuningi: 8 amapheya Ukuphazamisa amandla: DC250V/0.5A |
Shintsha okukhiphayo | Ubuningi: amapheya angu-6, okungamapheya angu-2 awokuvulwa ngokushesha |
Ukuxhumeka okungenantambo | Uhlobo lwesixhumi esibonakalayo: I-WIFI |
Uxhumano lwezintambo (i-Ethernet zokuxhumana interface) | Inombolo yezimbobo:l 2 Uhlobo lwesixhumi esibonakalayo: 100 megabytes LAN port, RJ45 |
Ukunikezwa kwamandla kagesi | Vi-oltage: AC/DC 220V, ukuchezuka okuvumelekile: -20%~15% FIsilinganiso: 47 ~ 65 Hz |
Okokufaka kwesignali encane ye-analogi | Inombolo yamashaneli: indlela eyi-12; Uhlobo lwesixhumi esibonakalayo: I-Aviation Plug, i-AC Voltage |
I-analog encane ephumayo yesignali | Inombolo yamashaneli: indlela eyi-12; Uhlobo lwesixhumi esibonakalayo: I-Aviation Plug, i-AC Voltage |
Isixhumi esibonakalayo se-USB | Ubuningi: 2 |
Izimo zendawo yokusebenza | Izinga lokushisa lokusebenza: -20°C~70°C Umswakamo: ≤95%, akukho ukufingqa |
Abanye | Isisindo: 15 kg Usayizi: 360×480×190(mm) Isixhumi esibonakalayo esiku-inthanethi: RJ45 Isibonisi: 10.4 intshiisikrini sokuthinta1024*768 isibonisi se-LCD sombala weqiniso |