I-GDOT-80A Insulation Oil Tester
●Sicela ufunde imanuwali yokusebenza ngokucophelela ngaphambi kokusebenza.
●Sicela uhlole ukuthi ingabe umhloli uxhumeke kahle yini emhlabeni ngaphambi kokuhlolwa.
●Akuvunyelwe ukuhambisa noma ukuphakamisa ikhava yokuhlola ngesikhathi sokuhlolwa ukuze kugwenywe ukulimala kwamandla kagesi aphezulu.Amandla kufanele acinywe ngaphambi kokufaka uwoyela wesampula.
●Bamba ngokucophelela lapho usuka noma uvala ikhava yokuhlola amandla kagesi aphezulu!
●Uma isihloli sisebenza ngendlela engavamile ngemva kokuphuka kukawoyela we-insulating, sicela ucime isihloli imizuzwana engu-10, bese uqala kabusha futhi.
●Ngemuva kokuthi iphepha lokuphrinta seliphelile, sicela ubheke ingxenye yencazelo yephrinta (noma isithasiselo semanuwali) ukuze ungene esikhundleni sephepha lokuphrinta ukugwema ukulimala kwekhanda lephrinta.
●Gcina isihloli sikude nomswakamo, uthuli nezinye izinto ezonakalisayo, futhi usigcine kude nemithombo yokushisa ephezulu.
●Phatha ngokucophelela kwezokuthutha.Ungabeki ubheke phansi.
●Imanuwali ingabuyekeza ngokufanele ngaphandle kwesinye isaziso kusenesikhathi.Uma kukhona umbuzo, sicela usithinte.
Isikhathi sewaranti salolu chungechunge unyaka owodwa kusukela ngedethi yokuthunyelwa.Sicela ubheke i-invoyisi yakho noma amadokhumenti okuthumela ukuze unqume izinsuku ezifanele zesiqinisekiso.I-HVHIPOT corporation iqinisekisa kumthengi wangempela ukuthi lo mkhiqizo ngeke ungabi nasici ezintweni ezibonakalayo kanye nomsebenzi owenziwayo ngaphansi kokusetshenziswa okuvamile.Phakathi naso sonke isikhathi sewaranti, hlinzeka ngokuthi lokho kulimala akunqunywanga i-HVHIPOT ukuthi kudalwe ukuhlukumeza, ukusetshenziswa kabi, ukuguqulwa, ukufakwa okungafanele, ukunganaki noma isimo esibi semvelo, i-HVHIPOT ikhawulelwe kuphela ukulungisa noma ukushintshwa kwaleli thuluzi phakathi nenkathi yesiqinisekiso.
Insimbi ye-GDOT-80C | 1 pc |
Inkomishi kawoyela (250ml) | 1 ama-pcs |
Intambo yamandla | 1 pc |
Gcina i-fuse | 2 ama-pcs |
Induku enyakazayo | 2 ama-pcs |
I-Standard gauge(25mm) | 1 pc |
Iphepha lokuphrinta | 2 imiqulu |
I-Tweezer | 1 pc |
Igayidi yomsebenzisi | 1 pc |
Umbiko wokuhlolwa kwefekthri | 1 pc |
I-HV Hipot Electric Co., Ltd. iye yalihlola ngokucophelela nangokucophelela le manuwali, kodwa ngeke siqinisekise ukuthi awekho amaphutha nokushiywa ngokuphelele encwadini.
I-HV Hipot Electric Co., Ltd. izibophezele ekwenzeni ngcono okuqhubekayo emisebenzini yomkhiqizo, kanye nokwenza ngcono ikhwalithi yesevisi, ngakho inkampani ihlala inelungelo lokushintsha noma yimiphi imikhiqizo nezinhlelo zesofthiwe ezichazwe kuleli bhukwana kanye nokuqukethwe kwaleli bhukwana ngaphandle kwangaphambi kwalokho. isaziso.
Ukufakwa kwangaphakathi kwemishini kagesi eningi ezinhlelweni zamandla, izinhlelo zikaloliwe, izitshalo ezinkulu ze-petrochemical kanye namabhizinisi, kwamukelwa kakhulu uhlobo lokufakelwa olugcwele uwoyela, ngakho-ke, ukuhlolwa kwamandla e-dielectric kawoyela okuvikelayo kujwayelekile futhi kuyadingeka.Ukuze kuhlangatshezwane nezidingo zemakethe, sithuthukise futhi sakhiqiza uchungechunge lwabahloli bamandla e-dielectric kawoyela afaka uwoyela ngokwezinga likazwelonke le-GB/T507-2002, izinga lemboni i-DL429.9-91 kanye ne-Electric Power Industry Standard DL/T846.7 yakamuva -2004 ngokwethu.Leli thuluzi, ngokusebenzisa i-single-chip microcomputer njengomgogodla, laqaphela ukusebenza okuzenzakalelayo, ukulinganisa okunembile okuphezulu, lithuthukisa kakhulu ukusebenza kahle komsebenzi kanye nokunciphisa umfutho wokusebenza kwabasebenzi.Ngaphezu kwalokho, incane ngosayizi futhi kulula ukuyithwala.
●Nge-microprocessor, gcwalisa ngokuzenzakalelayo ukuhlolwa kwe-voltage yokumelana nokujikeleza kukawoyela ngebanga elingu-0~80KV (okuhlanganisa ukukhuphula, ukunakekela, ukuxuba, ukuma, ukubala, ukuphrinta neminye imisebenzi).
●Isibonisi esikhulu sesikrini se-LCD.
●Ukusebenza okulula.Umshini uzoqedela ngokuzenzakalelayo ukuhlolwa kokumelana ne-voltage enkomishini eyodwa kawoyela oyisampula ngemva kokusetha okulula okwenziwa ngu-opharetha.Inani le-voltage ehlukanisiwe lezikhathi ezingu-1~6 nezikhathi zomjikelezo zizolondolozwa ngokuzenzakalelayo.Ngemuva kokuhlolwa, iphrinta eshisayo izophrinta inani ngalinye le-voltage ehlukanisiwe kanye nenani elimaphakathi.
●Ukulondolozwa kwamandla phansi.Ingakwazigcina imiphumela yokuhlolwa engu-100 futhi ubonise izinga lokushisa lamanje le-ambient kanye nomswakama.
●Yamukela i-microcomputer ye-single-chip ukuze ukhulise i-voltage ngesivinini esingaguquki.I-voltage frequency inembile ku-50HZ, qinisekisa ukuthi yonke inqubo kulula ukuyilawula.
●Ngokuvikelwa kwe-over-voltage, over-current kanye nomkhawulo wokuqinisekisa ukuphepha kwabaqhubi.
●Ngomsebenzi wokubonisa izinga lokushisa elilinganisiwe newashi lesistimu.
●Xhumana nekhompyutha ngesixhumi esibonakalayo se-RS232 esijwayelekile.
Ukunikezwa kwamandla kagesi | I-AC220V±10%, 50Hz |
I-voltage yokuphumayo | 0~80kV(Kuyakhethwa) |
Amandla | 1.5kVA |
Amandla | 200W |
Isivinini sokukhuphuka kwamandla kagesi | 2.0~3.5kV/s (Iyalungiseka) |
Amandla kagesiukukalaukunemba | ±3% |
Ukuhlanekezela kwe-Waveform | ≤3% |
Isikhawu sokuthuthukisa | 5min (Iyalungiseka) |
Isikhathi sokuma | 15min (Iyalungiseka) |
Izikhathi zokuthuthukisa | 1~6 (Okukhethwa kukho) |
Isebenzaimvelo | Tizinga lokushisa: 0℃-45℃ |
Hubuncane:Max.umswakama ohlobene75% | |
Ubukhulu | 465x385x425mm |