I-GD-2136H Uhlelo Lokuthola Iphutha Lekhebula
I-GD2136H Cable Fault system iyithuluzi elibalulekile lokugcina zonke izinhlobo zezintambo.Isebenzisa indlela ehlukahlukene yokuthola ukuhlola amaphutha ekhebula, efanele amazinga ahlukene amakhebuli kagesi kagesi kanye nezintambo zokuxhumana.
Uhlelo luqukethe amayunithi angezansi:
1. I-GD-2131H Impulse Generator
2. I-GD-2132 Indawo Yephutha Lekhebula
3. GD-2133 Cable Fault Tester
4. Ezinye izesekeli
I-GD-2131H Impulse Generator
Isetshenziselwa ukukhiqiza umfutho we-HV uma usebenzisa indlela ye-flashover engaguquki ukuze kutholwe iphutha eliphezulu le-impedance.
●Ikhono elivuthayo elinamandla, amandla amakhulu okushisa angu-1000W, iphuzu lokuqhekeka lingashiswa ngesikhathi esifushane futhi ukumelana kwephuzu lokuphuka kuyancipha.
●Uma usebenzisana ne-GD-2133 Cable Fault Tester, kunezindlela ezimbili zokuthola indawo:
a.I-low voltage pulse: Uma kusetshenziswa kuphela i-GD-2133, ikhebula elivulekile lesifunda kanye namaphutha okumisa ikhebula aphansi angatholakala, futhi ubude bekhebula bungalinganiswa noma kutholwe isivinini samagagasi sekhebula.
b.I-flashover ye-voltage ephezulu: I-wave wave ye-pulse voltage ekhiphayo yephoyinti lephutha isampula ngokukhipha igebe le-sphere, elingathola ibanga lephutha.
●Khiqiza umfutho wefrikhwensi engashintshi.Uma usebenzisana ne-GD-2132 Cable Fault Locator, kukhona imisebenzi elandelayo:
a.Indlela yomsindo isetshenziselwa ukuqedela indawo enembile yamaphoyinti amaphutha okumelana okuphezulu kanye ne-flashover.
b.Ukuze ukhombe umzila wekhebula, khomba ikhebuli ekhethekile.
c.Ngokuwohloka kwensimbi(isisekelo esifile), kusetshenziswa isilinganiso senkundla kazibuthe ukuze kutholwe ngokunembile.
●Ingasetshenziswa futhi ku-DC HV ukumelana nokuhlolwa.
●Okokufaka kwamandla: AC 220V,50Hz
●I-voltage ephumayo: DC 0-32kV (iyalungiseka)
●Amandla alinganiselwe: 2000VA
●I-Max.energy: 2048J, 4uF
●I-DC flashover voltage: 32kV
●I-DC flashover yamanje: 63mA
●I-Max.impulse yamanje: 500mA
●Indlela yokukhipha: I-DC HV, isikhathi esisodwa, umjikelezo
●Isikhathi sokukhipha umjikelezo: imizuzwana engu-3-6
●Izinga lokushisa lemvelo: 0-40 ℃
●Ukuswakama:<75% RH
●Ukuphakama: <1000m
●Izinga le-insulation: A
●Ubukhulu: 430*540*410mm
●Isisindo: cishe 31kg.
Kubandakanya isidlulisi, umamukeli, i-inductive probe, ukutholwa kohlobo okungenzekaifreyimu.Kufanelekile ukuhlola zonke izinhlobo zekhebula lamandla ngomqhubi wensimbi.
Umsebenzi wayo oyinhloko ukuthola indawo engafanele yokufakelwa, ukuthola isifunda kanyeukujula kwekhebula lamandla.
●Ukuzwela okuphezulu
●Ukukhukhuleka okumile okuphansi
●Ukunemba okuphezulu kokuthola indawo
●Ukuphikisana nokuphazanyiswa
●Isikrini se-LCD ukukhombisa isignali nesimo
●Ibhethri ye-Li eyakhelwe ngaphakathi
●Ukulandela nokubeka ibanga: ikhebula lendawo 3km, enye ikhebula efika ku-20km
●Ukuthola ibanga le-impedance: 0-5MΩ.
●Ukuthola ukunemba: ≤±10cm.
●Ukujula kwekhebuli: <3m.
Ingahlola amaphutha we-flashover ephezulu ye-impedance, ephezulu-phansiukumelana nesisekelo, i-short-circuit, ukunqanyulwa kwekhebula, uxhumano olubikuzo zonke izinhlobo zezintambo zamandla (i-voltage degree 1kV-35kV),ikhebula lendawo, ikhebula lokuxhumana, ikhebula elikhoaxial kanye nolayini ongaphezulu wensimbi.
Ingakwazi futhi ukukala ubude bekhebula nesivinini sokusabalalisa sesivinini samagagasi kagesi kukhebuli.
●Ukuhlola okuphephile, okusheshayo nokunembile.Isebenzisa indlela ye-LV impulse kanye nokutholwa kwe-HV flashover, okuhlola zonke izinhlobo zamaphutha ekhebula.Ikakhulukazi i-flashover kanye namaphutha aphezulu e-impendance wezintambo, ingahlolwa ngokuqondile ngaphandle kokuvutha;uma ifakwe ngendawo yokulinganisa i-acoustic, indawo eqondile yephutha inganqunywa ngokunembile.
●Ukusebenzisa ubuchwepheshe besampula bedatha yesivinini esikhulu.Isivinini sesampula se-A/D singu-100Mhz, ukwenza isinqumo sokufunda sethuluzi sibe ngu-1m futhi indawo eyimpumputhe yokutholwa ingu-1m.
●Ifomu le-Wave nedatha kuboniswa ngokuzenzakalelayo esikrinini esikhulu se-LCD.
●Ifomu le-Wave kanye nokugcinwa kwepharamitha, khumbula umsebenzi.
●Umsebenzi wokuqhathanisa i-waveform yokuhlola yephutha lekhebula ne-waveform evamile.
●Umsebenzi wokwelula wefomu yegagasi.
●Khombisa ngokuqondile iphuzu lephutha nendawo yokuhlola ibanga eliqondile noma ibanga elihlobene.
●Shintsha isivinini sokusakazeka nganoma yisiphi isikhathi ngokuya ngamakhebula okuhlola ahlukene.
●Ibhethri eyakhelwe ngaphakathi.Usayizi omncane, uyaphatheka ukuthwala.
●Ibanga eliphezulu lokuhlola: 15km(Intambo evuliwe kufika ku-100km).
●Ukutholwa okungaboni: 1m
●Ukulungiswa: 1m
●Ukusetshenziswa kwamandla: 5VA
●Izinga lokushisa lemvelo: 0-40℃(ukushisa okulinganiselwe:-10℃-50℃)
●Umswakamo ohlobene: 40℃(20℃90) %RH
●Umfutho we-atmospheric: 86-106Kpa
●Usayizi: 275 * 220 * 160mm
●Isisindo: 1.8kg
Ezinye izesekeli zihlanganisa AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod.