Isistimu Yokuthola Iphutha Lemoto Ye-GDCF-900T
Uhlelo Lokuthola Iphutha Lekhebula Elikhweziwe Lemoto lusetshenziselwa ukulungisa Iphutha Lekhebula (ukushiswa), Indawo Yangaphambili, Indawo Yomzila, Ukukhonjwa Kwephini kanye Nokuhlolwa kwezintambo ze-HV & LV zezinhlobo&osayizi abahlukahlukene.Isethi ifanele ukwenza imisebenzi eminingi eshiwo ngenhla kumakhebuli kagesi wamazinga kagesi ahlukahlukene ikakhulukazi ama-33KV, 11KV, 415V kanye namakhebuli okulawula anebanga elingu-1.1 KV.Isethi izosetshenziselwa izinhlobo zamakhebula okungukuthi i-XLPE, i-PVC, i-PILC enomqhubi we-Al / Cu.Izintambo zibekwe ngaphansi komhlaba (ngaphansi komhlaba ongenalutho, imisele, noma indawo ye-RCC, Ukubhoboza Okuvundlile ngepayipi le-HDD), ngaphezu komhlabathi noma ingxenye ngaphansi & ngokwengxenye ngaphezu komhlaba ngekhebula eliphakeme lobude obungu-25Km.
Indawo yephutha lekhebula ifaneleka ukuthola iphutha nokukhomba izinhlobo ezilandelayo zamaphutha ekhebula.
●Ukumelana okuphezulu
●Ukumelana okuphansi
●Amaphutha ohlobo oluphazima kweso.
●Le yindawo ka Sheath Fault
●Uhlelo lusebenzisa ama-pulses amaningi(indlela yokubonisa i-ARC), ama-pulses aphindwe kathathu, indlela ye-impulse, indlela ye-flashover, indlela ye-TDR yokwenza ukulinganisa okunzima kwazo zonke izinhlobo zamaphutha ekhebula.
●Isebenzisa indlela kazibuthe ye-acoustic ukuze kutholwe amaphuzu amaphutha.
●Isebenzisa isimiso sokungeniswa kwe-electromagnetic ukulandelela ikhebula elingaziwa nokuthola ukujula kwekhebula.
●Khomba futhi ubhoboze izintambo zezintambo.
●Thola futhi ulinganise umgodla wekhebula.
Uhlelo lokuhlola iphutha lekhebula elifakwe emotweni lisebenzisa idizayini ebanzi ehlelekile neyomuntu ukuze kutholwe iphutha eliyinhloko lezintambo zikagesi ze-33KV, 11KV kanye ne-415V, ukutholwa kwendawo enephutha yomgodla wangaphandle, indawo yokunquma okunembile, ukuhlolwa kwendlela, ukuhlonza okubukhoma, ukubhoboza kokuphepha. , ukumelana ne-DC ukuthi zonke izinhlobo zamathuluzi okuhlola, okokusebenza kokusabalalisa amandla, izesekeli namathuluzi asizayo adingekayo afakwe ezimotweni ezikhethekile eziguquliwe.
Yonke inqubo yokuhlola iphephile futhi ivaliwe, futhi imisebenzi yokuhlola ihlukene futhi imiphumela yokuhlola inembile.
●Imoto inezingxenye ezintathu: i-cab, igumbi lokuhlinza kanye negumbi lemishini.
●Isakhiwo sekhonsoli yokusebenza siyafaneleka, futhi ukuhlolwa kokufakwa kwekhebula, ukwahlulela kwesakhiwo esinephutha, nebanga lokukala amaphutha lingaqedwa ngokuphelele emotweni.
●Umsingathi wokuhlola amaphutha angaqedela ukulinganisa okuqinile kwebanga lephoyinti lephutha futhi angabamba ngokuzenzakalelayo indawo.
●Igumbi lokulawula lakhiwe ngengxenye ezimele ye-high-capacity high-voltage, i-LCD ibonisa isikhathi sangempela samanje kanye ne-voltage, ngokuqonda okuphelele ukusebenza nokukhishwa kwe-high-voltage.
●Ukuhlonza ikhebula, umsingathi wokuhlolwa kwendlela kushunyekwe egunjini lokuhlinza.
●Ithebula lokusebenza lenziwe nge-epoxy resin ukwenza yonke icoceke futhi ibe yinhle.Ikhabethe lamathuluzi liklanywe ngokwenziwa kwensimbi kanye nezingidi zikaloliwe ezimunca umsindo.Iqinile, ayisheleli, ayigugi futhi kulula ukuyikhuhla.Iqinisekisa ukuphepha kwenqubo yokuhlola.
Isakhiwo sangaphakathi
1——Indawo yokushayela
2——Indawo yokusebenza
3——Iyunithi yokulawula emaphakathi
4——Ukucubungula isignali yephutha
5——Ikhabethe lensimbi yokuhlola imoto
6—— Iyunithi yokuhlola i-High-voltage
7——Iyunithi yokuvikela
8——Ijeneretha
9—— High Voltage Test reel yekhebula
10——I-reel yekhebula ephansi
11——Udonga lokuzihlukanisa
Lonke uhlelo luhlanganisa
Into | Igama | Imodeli No. | Qty |
1 | Vehicle | -------------- | 1 |
2 | Isihloli sephutha sekhebula le-multi-pulse | GD-4133 | 1 |
3 | I-Pulse coupler
| I-GD-4133S
| 1 |
4 | Cukwazi iphutha locator
| I-GD-4132
| 1 |
5 | Hi-voltage impulse generator | GD-2131H
| 1 |
6 | Cisihlonzi esikwaziyo | I-GD-2134D
| 1 |
7 | Cidivayisi ekwazi ukubhoboza | I-GD-2135B | 1 |
I-GD-2131H Impulse Generator
Isetshenziselwa ukukhiqiza umfutho we-HV uma usebenzisa indlela ye-flashover engaguquki ukuze kutholwe iphutha eliphezulu le-impedance.
●Ikhono elivuthayo elinamandla, ubuningi.Amandla avuthayo angama-1000W, indawo yokuqhekeka ingashiswa ngesikhathi esifushane futhi ukumelana kwephuzu lokuqhekeka kwehle.
●Uma usebenzisana ne-GD-4133 Cable Fault Tester, kunezindlela ezimbili zokuthola indawo:
a.I-low voltage pulse: Uma kusetshenziswa kuphela i-GD-4133, ikhebula elivulekile lesifunda kanye namaphutha okumisa ikhebula aphansi angatholakala, futhi ubude bekhebula bungalinganiswa, noma kungatholwa isivinini samagagasi sekhebula.
b.I-flashover ye-voltage ephezulu: I-wave wave ye-pulse voltage ekhiphayo yephoyinti lephutha isampula ngokukhipha igebe le-sphere, elingathola ibanga lephutha.
●Khiqiza umfutho wefrikhwensi engashintshi.Uma usebenzisana ne-GD-4132 Cable Fault Locator, kukhona imisebenzi elandelayo:
a.Imvamisa yomsindo: thola i-impedance ephezulu, amaphutha e-flash-over.
b.Ukuze ukhombe umzila wekhebula, khomba ikhebuli ekhethekile.
c.Ukuqhekeka kwe-metallic (isisekelo esifile), kusetshenziswa isilinganiso senkundla kazibuthe ukuze kutholwe ngokunembile.
●Ingasetshenziswa futhi ku-DC HV ukumelana nokuhlolwa.
●Okokufaka kwamandla: AC 220V,50Hz
●I-voltage ephumayo: DC 0-32kV (iyalungiseka)
●Amandla alinganiselwe: 2kVA
●Ubukhulu.amandla: 2048J, 4uF
●I-DC flashover voltage: 32kV
●I-DC flashover yamanje: 63mA
●Ubukhulu.amandla wamanje: 500mA
●Indlela yokukhipha: I-DC HV, isikhathi esisodwa, umjikelezo
●Isikhathi sokukhipha umjikelezo: imizuzwana engu-3-6
●Izinga lokushisa lemvelo: 0-40 ℃
●Ukuswakama:<75% RH
●Ukuphakama: <1000m
●Izinga le-insulation: A
●Ubukhulu: 430*540*410mm
●Isisindo: cishe 31kg.
I-GD-4132 Cable Fault Locator
Kubandakanya iyunithi eyinhloko, inzwa ye-acoustic nekazibuthe, i-headphone emelene nomsindo neshaja.Kufanelekile ukuhlola zonke izinhlobo zekhebula lamandla nge-conductor yensimbi.Umsebenzi wayo oyinhloko ukuthola indawo yokufaka engasebenzi kahle, ukuthola ukujikeleza nokujula kwekhebula lamandla.
●I-Acoustic Magnetic ithola ngesikhathi esifanayo
●Ikhono eliqinile lokulwa nokuphazamiseka
●Nge-headphone anti-nomsindo.
●320*240 LCD isibonisi sesikriniIbhethri ye-Li eyakhelwe ngaphakathi enomthamo omkhulu, eneshaja esheshayo.
●Isibonisi se-acoustic ne-Magnetic signal waveform, isignali nomsindo kulula ukuhlukanisa.
●Usebenzisa ikhesa ukulinganisa ukubambezeleka kwe-acoustic nokuzibuthe, thola ngokunembile iphuzu lephutha.Ngokuvumelana ne-polarity yokuqala ye-waveform kazibuthe, ingathola futhi ithole umzila.
1. Indawo umsebenzi
a.Ibhendi yokudlulisa isignali ye-Acoustic: imvamisa yesikhungo esingu-400Hz, umkhawulokudonsa ongu-200Hz
b.Ukuzuza kwesignali: 80dB
c.Ukunemba kwendawo: 0.1m
2. Ukuhlinzekwa kwamandla a.Ibhethri ye-Li eyakhelwe ngaphakathi, amandla kagesi angu-7.4V, amandla angu-3000mAH.b.Ukusetshenziswa kwamandla: 300mA, isikhathi sokusebenza esiqhubekayo 9hours.c.Ishaja: okokufakaAC220V±10%, 50Hz.Okuphumayo okungajwayelekile 8.4V,DC 1A d.Isikhathi sokushaja: Amahora angu-4
3. Ubukhulu: 270mm*150mm*210mm
4. Isisindo: 1.5kg.
5. Sebenzisa isimo Sezinga lokushisa -10℃--40℃, umswakama 5-90%RH, ukuphakama <4500m
I-GD-4133 Cable Fault Detector
I-GD-4133 Cable Fault Detectot isetshenziselwa ukukala ibanga phakathi kwamaphutha ekhebula.Kulula ukuyisebenzisa futhi ine-interface enobungane.
Ingasetshenziswa yodwa ngaphansi kwemodi ye-low voltage pulse.Ngaphansi kwemodi ye-pulse current, idinga ukusebenza ne-GD-2131 high voltage generator.Ngaphansi kwemodi ye-pulse eminingi, i-coupler ye-GD-4133S kufanele isetshenziswe ndawonye.Ngemuva kokutholwa kwebanga, isikhombisi sephutha se-GD-4132 kufanele sisetshenziselwe ukukhomba iphutha.Le mikhiqizo ingahlanganiswa ibe yisethi yokusebenza okuphezulu kanye nesistimu yokuhlola iphutha lekhebula.
●Isikrini se-LCD esingu-7inch, isikhombikubona esinobungane.
●Indlela yokubeka amabanga amaningi:
Indlela ye-low voltage pulse: ilungele ukutholwa kwephutha eliphansi lokumelana, iphutha lesifunda esifushane, iphutha lesekethe elivulekile.Ingasetshenziswa futhi esilinganisweni sobude bekhebula, amalunga amaphakathi, amalunga e-T, kanye nejoyinti yokunqanyulwa kwekhebula.Le ndlela futhi ingasetshenziswa ukulungisa isivinini samagagasi.
Indlela yamanje ye-Pulse: Ifanele ukukalwa kwebanga lephutha eliphezulu lokumelana, iphutha lokuphuka.Ukusebenzisa i-coupler yamanje ukuqoqa amasignali kusukela kuntambo yomhlaba, kwenza umsebenzisi abe kude ne-voltage ephezulu.Le ndlela iphephile futhi ithembekile.
I-pulse eminingi: indlela ethuthukisiwe yokukala ibanga.I-waveform kulula ukuyibona futhi ukunemba kuphezulu.
●200MHz isampula yesikhathi sangempela.Ubukhulu.Ukulungiswa kokulinganisa okungu-0.4m.Inendawo encane efile futhi ikhethekile kukhebuli emfushane kanye nekhebula eliseduze.
●Thinta isikrini bese ucindezela ukhiye wokusebenza
●Ikhophi ye-PIP (pic. isitoreji sesikhashana)
●Kuzoba newindi elikhulu futhi amawindi amathathu okugcina esikhashana angabheka ama-waveform amathathu ndawonye.
●Isistimu yokusebenza eyakhelwe ngaphakathi
Ukuphathwa kwesoftware okukhethekile yokuthuthukisa isoftware, ukwenza isipele nokubuyisela.
●Umsebenzi wesikali
Indawo yokuqala, abathintwayo abangu-10, iphutha lekhebula elilodwa kanye nobude obubodwa obugcwele kungase kusethiwe.
Bonisa isikali nokuhlola i-waveform ndawonye
●Isitoreji se-Waveform nokuxhumana nekhompyutha.
Ukugcinwa kwangaphakathi kwama-waveforms.
Nge-USB, ukulanda noma ukulayisha idatha
Ukuxhumana ngekhompyutha
●Ukuphathwa kwamandla
Ukukhanya kwangemuva kuba buthaka uma kungekho ukusebenza emizuzwini emi-2 futhi kucime emizuzwini eyi-10 uma kungekho msebenzi.
Ibhethri le-Polymer Lithium-ion elakhelwe ngaphakathi.
Isikhathi sokusebenza singafika emahoreni ama-5 ngokusetshenziswa ngakunye.
Ikesi eliqinile, kulula ukulithwala.
Izindlela zokuthola indawo | Indlela ye-low voltage impulse Indlela yamanje ye-Ipulse Indlela yomfutho eminingi uma ifaniswe ne-GD-4133S |
Ubukhulu.Imvamisa yesampula | 200MHz |
Zuza ububanzi | 0-70dB |
I-voltage ephansi ye-impulse voltage | 30V |
Ubukhulu.isixazululo | 0.4m |
Ubukhulu.Ithola ububanzi | 100km |
Indawo efile | 2m |
Ibhethri | Amabhethri e-nickel-metal hydride aphinde ashajwe, isikhathi sokubekezela amahora angaphezu kwama-5 |
Isixhumi esibonakalayo sokuxhumana | I-USB |
Ukunikezwa kwamandla kagesi | Okokufaka kwe-AC220V,50Hz,i-2A yamanje,shaja amahora angu-8 |
Dim. | 274×218×81mm |
Isisindo | 3.5kgs |
Izinga Lokushisa Lokusebenza | -10℃-40℃ |
Umswakama | 5-90%RH |
Ukuphakama | <4500m |
I-GD-4133S Multiple Pulse Coupler
Isebenza ndawonye ne-GD-4133 Cable Fault Detector, esetshenziselwa ukuthola iphutha elivuzayo eliphezulu, iphutha le-flashover, umhlaba ongasebenzi kahle kanye nephutha lesekhethi evulekile yamakhebuli kagesi.I-GD-4133S inikeze isignali yokuhlanganisa i-pulse ye-GD-4133 futhi iyihlukanise nempahla yamandla kagesi aphezulu.
●Ukusebenzisa ubuchwepheshe obusezingeni eliphezulu kakhulu bokulinganisa kwamagagasi amaningi kanye nebhalansi yamagagasi.
●Ngokuvikeleka kwe-HV, isekethe yokulinganisa namandla omfutho kagesi aphezulu ahlukaniswa ngogesi.
●Izintambo ezilula, eziphephile futhi ezinokwethenjelwa.
Imininingwane
●I-Pulse voltage: 300V (PP)
●I-voltage ye-impulse evumelekile: <35kV
●Amandla okufakwayo avumelekile: <2000J
●Okokufaka kwamandla: 220VAC, 50Hz
●Ubukhulu: 560*230*220mm
●Isisindo: 7kg.
Isihlonzi sekhebula se-GD-2134D
Isihlonzi Sekhebula se-GD-2134D sihlanganisa isidluliseli nomamukeli, singasetshenziswa ukuthola umkhondo nokujula kwamakhebuli angaphansi komhlaba namapayipi ensimbi, nokuhlonza ikhebula esixukwini sezintambo.
●Bonisa ngokuqondile indawo yepayipi.
●Inkomba yomcibisholo wesokunxele/kwesokudla Wokulandelela Umzila Wekhebula.
●Isikhathi sangempela sokulinganisa ipayipi indlela yamanje kanye nokwaziswa okungamanga/okulungile ngaphansi kobuningi bemvamisa.
●Inkomba elungile/ engamanga.Izokhomba phambili lapho ikhebuli etholiwe ilandelwa ngendlela efanele.Uma kungenjalo, izokhomba emuva futhi izobonisa "?".
●Ukulinganisa okuzenzakalelayo kokujula nokwamanje.
●Ukuhlonza ikhebula: Ukuhlonza i-clamp kanye ne-stethoscope identification.Ukuhlonza intambo kungakala i-amplitude yamanje nesiqondiso sekhebula ngokunembile futhi kunikeze umphumela onembile.Ukuhlonza i-Stethoscope kuyindlela evamile lapho ingafaneleki ukusebenzisa ukuhlonza i-Clamp.Kuyizintambo ezilula zokuhlonza i-Stethoscope.
●Kusetshenziswa i-rack(into ozikhethela yona) ukuthola indawo enephutha yokubeka phansi.Akudingekile ukulungisa endaweni eyiziro.Umcibisholo ukhombisa isiqondiso sephoyinti lephutha.
●Ukwenziwa kwedijithali okugcwele okugcwele ukunemba nokucutshungulwa kwesampula, okunebhande lokwamukela elincane kanye nokuphazamiseka okuqinile.Icindezela ngokugcwele imvamisa yamandla kanye nokuphazamiseka kwe-harmonic kumakhebuli aseduze agijimayo.
●Ukutholwa okusebenzayo nokutholwa kokwenziwayo.
●Ibhethri le-lithium elakhelwe ngaphakathi.Ukucisha okuzenzakalelayo lapho i-voltage ingaphansi noma ingasebenzi isikhathi eside.
I-Transmitter
●Okukhiphayo (Imodi Emithathu): Okukhiphayo kokuxhumeka okuqondile, ukuphuma kwe-Clamp Coupling (ngokukhethwa kukho), ukufakwa kwe-radiation.
●Imvamisa (6 ongakhetha): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, okuhlanganisa 640Hz kanye 1280Hz imvamisa eyinkimbinkimbi.Ingabona umsebenzi wenkomba elungile/engamanga kanye nokuhlonza ipayipi ngosizo Lomamukeli.
●Iphutha lokukhipha isignali ukuze kutholwe iphutha lokumiswa kwePipe.
●Okukhipha amandla: Ubukhulu.10W, 10steps adjustable.
●I-voltage yokuphuma kokuxhumeka okuqondile: I-Max.150Vpp.
●Ukumatanisa okuzenzakalelayo kwe-impedance nemisebenzi yokulayisha ngokweqile&ukuvikela isifunda esifushane.
●Ukunikezwa kwamandla: Ibhethri ye-Lithium egcwalisekayo yangaphakathi, ama-4pcs, imodeli no.18650.i-7.4V, 6.8Ah.
●Iqinile futhi iyaphatheka.
Umamukeli
●Imodi yokufaka: ikhoyili yokwamukela eyakhelwe ngaphakathi, i-clamp yokwamukela(uyazikhethela), i-echometer(uyazikhethela), I-rack(uma uthanda).
●Amabhendi amafrikhwensi amabili okutholwa kokwenziwa: ifrikhwensi yamandla kanye nefrikhwensi yomsakazo (RF).Asikho isidingo sokuxhuma ne-audio frequency generator.
●Ithola imvamisa:
Imvamisa yokuthola esebenzayo: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
Imvamisa yokutholwa kwe-PF: 50/60Hz kanye no-250/300Hz (okulungisekayo komsebenzisi)
Imvamisa yokutholwa kwe-RF: imvamisa yesikhungo ngu-10kHz, 33kHz, 83kHz ngokulandelanayo.
●Imodi yokutholwa: indlela ephezulu, indlela ewumngcingo, indlela engenalutho.
●320 * 240 pixel LCD isikrini.
●Ibhethri ye-lithium eyakhelwe ngaphakathi, 2pcs 18650 Li ibhethri, igama elithi.7.4V, 3.4Ah.
●Iqinile futhi iyaphatheka.
Eminye imininingwane
●Usayizi: i-transformer 270 * 220 * 85mm, umamukeli 700 * 270 * 120mm.
●Isisindo: Transmitter 2.2kg, umamukeli 2.2kg.
●Ishaja: okokufaka AC 100-240V, 50/60Hz, okukhiphayo DC 8.4V, 2A.
●Isimo sokusebenza: Izinga lokushisa -10--40 ℃.Umswakamo 5-90% RH, Altitude<4500m.
I-GD-2135 Cable Puncture Device
I-GD-2135B Idivayisi Yokubhoboza Ikhebula iphinde ibe isihlonzi sekhebula, ukuhlonza ikhebula esixukwini sezintambo.
Kuyidivayisi yokubhoboza ephephile engathinteki, enerimothi nesilawuli sesikhathi.
Le divayisi ihlanganisa izingxenye ezimbili, idivayisi yokubethela kanye nedivayisi yokulawula.Isebenza ngebhethri, ehlukanisa idivayisi yokubhoboza ohlelweni lwamandla, ukuze kuqinisekiswe ukuphepha kokunikezwa kwamandla.
●Ilungele ukubhoboza zonke izinhlobo zekhebula lamandla, iphephile futhi inokwethenjelwa.
●Izindlela ezimbili zokusebenza, kufaka phakathi isilawuli kude nesikhathi.Izinkinobho ezimbili ezizosetshenziswa ukungena kwimodi yokusebenza, ziqinisekisa ukuphepha komsebenzisi.
●Izinkinobho ezimbili ezikude (ukhiye C no-D icindezelwe kanyekanye).Ukuqinisekisa ukwamukela okuthembekile, i-antenna yokudlulisa yesilawuli kude kufanele ikhishwe ngokuphelele.
●Ukusebenzisa izibhamu ezimbili ukubhoboza ngama-engeli akabili.Umsebenzi owodwa wokuhlola wokuqeda ukubhoboza okuphindwe kabili.
●Nge-alamu yomsindo nesibonisi se-LCD.
●Idizayini yokuvikela eminingi ngoomakhenikha nezinto zikagesi.
●Okukhethekile okudizayinelwe ukubhoboza ikhebula, okugxilwe ngokuqondile kukhebula, kufakwe kunoma iyiphi i-engeli.
●Isebenzisa amandla ebhethri, alungele ukusetshenziswa ngaphandle kokunikezwa amandla.Futhi, ihlukanisa idivayisi yokubhoboza ohlelweni lwamandla, ukuze kuqinisekiswe ukuphepha.
●Ibanga elikude elingenantambo: ≤ 20M.
●Isicelo sekhebula: zonke izintambo zamandla ≤ ¢125mm
●Amandla okusebenza: 6pcs 1.5V ibhethri.
●Isimo sokusebenza: izinga lokushisa -10--50 ℃, umswakamaRH<95%.
●Isisindo: 15kg kuhlanganise necala le-aluminium.
●Usayizi: 48 * 45 * 16cm