I-GDB-P Auto Transformer Ishintsha Isihloli Sesilinganiso
Ngokusho kwe-IEC kanye namazinga afanele kazwelonke, ukuhlolwa kwe-transformer turns ratio kuwumsebenzi odingekayo ohlelweni lokukhiqiza isiguquli samandla, ukunikezwa komsebenzisi kanye nokuhlolwa kokulungisa.Le ndlela ingaqapha ngokuphumelelayo ikhwalithi yemikhiqizo ye-transformer embonini kanye nenqubo yokusebenzisa, ivimbele ukuphenduka kwe-transformer ukuze iguqule isifunda esifushane, isifunda esivulekile, iphutha lokuxhuma, iphutha langaphakathi noma iphutha lokuxhumana le-tap changer.
I-GDB-P Transformer turns ratio tester inezici zokusebenza okulula, umsebenzi ophelele, idatha ezinzile nethembekile.Kuze kube manje, i-GDB-P ingeyokuqala e-China ingakwazi ukwenza ukulinganisa okuyimpumputhe (inike amandla ukulinganisa okunembile kanye ne-engeli yesigaba sokulinganisa ngaphandle kokwazi imodi yokuxhuma kanye nesimo seqembu se-transformer ehloliwe);Ingakwazi ukuhlangabezana nezidingo ezihlukahlukene zokuhlolwa kwesilinganiso se-transformer enkulu, emaphakathi nezincane (okuhlanganisa iziguquli zohlobo lwe-Z, iziguquli ezilungisa kabusha, iziguquli zesithando somlilo kagesi, ama-non-integral point shifting phase phase, transformer traction, Scott kanye nama-reverse Scott transformer).
I-GDB-P yamukela isikrini esikhulu esinombala ogcwele i-LCD ukuze siboniswe, isikhombimsebenzisi esigcwele se-English sokusebenza kwesithombe esinolwazi oluncane, isixhumi esibonakalayo esinamapharamitha amaningi, isibonisi segrafu ye-vector kanye nokwahlulela kwezintambo kunikeza isisekelo esinokwethenjelwa sokuhlola ukufaneleka kwesekhethi.Indlela yokusebenza yekhibhodi ye-silicone ye-conductive, isibambo esihle, kulula ukuyifunda.Isitoreji sedatha esakhelwe ngaphakathi esikhulu, Ingonga idatha yokuhlola esizeni kufika kumasethi ayi-1000.Ingahlinzeka ngesofthiwe yokuphatha ikhompuyutha encane engemuva kwesiteji, idlulisele imiphumela kukhompuyutha nge-U disk, ikhiqize imibiko, iphrinte, futhi ibone ukuphathwa kwekhompyutha.
Ithuluzi lamukela igobolondo lepulasitiki lobunjiniyela, elihle futhi elisebenzayo.
●Ukuhlolwa kwangempela kwesigaba sesithathu: okokufaka kwamandla esigaba esisodwa, i-digital synthesis yangaphakathi yesigaba sesithathu umthombo wesignali ye-sine wave, ikhiqiza amandla okuhlola ezigaba ezintathu (ukuhlanekezela kungaphansi kuka-0.1%, ukulingana kungcono kuno-0.05%) okukhiphayo ngokusebenzisa i-amplifier yamandla aphezulu, umphumela wokuhlola unokulingana okungcono, futhi ngeke kube nokuhlanekezela okungalungile kweqembu.
●Inamandla: iyakwazi ukwenza ukukala kwesigaba esisodwa, kodwa futhi nokuhlolwa okuzenzakalelayo kokujika kwezigaba ezintathu kungenziwa.Ukulinganisa i-polarity, i-engeli yesigaba ngesigaba esisodwa nesesithathu, ukulinganisa okuphelele kwe-AB, BC, CA isilinganiso sesigaba sesithathu kanye nenani le-engeli yesigaba, iphutha, nokuma kokuthinta, amanani ompompi ngesikhathi esisodwa, angakwazi ukukhomba ngokuzenzakalelayo inombolo yeqembu.
●Umsebenzi wokulinganisa i-engeli yesigaba: ukulinganisa ngokunembile i-engeli yesigaba phakathi kohlangothi lwe-voltage ephezulu nephansi, isilinganiso kanye ne-engeli ye-non-integer transformer kungalinganiswa.
●Umsebenzi wokubonisa ama-engeli ayisithupha: imiphumela yokuhlolwa iboniswa nenombolo kanye nomdwebo we-vector wama-engeli ayisithupha, futhi isimo seqembu lokuxhumana kwe-transformer sibonakala ngokunembile.
●Umsebenzi wokuhlola oyimpumputhe: asikho isidingo sokukhetha imodi yokuxhuma neqembu lokuxhuma, asikho isidingo somjikelezo omfushane wangaphandle lapho ukala i-Y/△, △/Y transformer, imodi yokuxhuma ingashintshwa ngokuzenzakalelayo ngokuya kokuqukethwe kokuhlola okukhethiwe.Isilinganiso nesilinganiso senombolo yeqembu singenziwa ku-transformer ngaphandle kwe-nameplate.
●Ukuhlolwa kokuthepha: ukulinganisa okusheshayo kwesilinganiso nephutha lesilinganiso endaweni yokushintsha ukuthepha ngakunye, isilinganiso esilinganiselwe sidinga ukufaka kanye kuphela, asikho isidingo sokuphinda okokufaka ukuze kubalwe iphutha lesilinganiso sokuma kokuthepha ngakunye.
●Ijika isilinganiso kanye nokusebenza kwesilinganiso sesilinganiso se-voltage egijima, isilinganiso esisebenzayo singabonisa ngempela inani langempela lesilinganiso se-voltage ye-transformer ngaphansi kwesimo sokusebenza.
●Ukumelana nokudlidliza okuhle: ukusetshenziswa kwezixhumi zamasosha kuthuthukisa ukusebenza kokudlidliza.
●Ithatha isikrini sombala esinencazelo ephezulu engu-5.6 intshi, umphumela wedatha wokubonisa kanye nomphumela we-vector diagram kuyaqondakala futhi kuthambile.
●Umthombo wedijithali we-sine odidiyelwe owenziwe ngedijithali, ukuhlanekezela kungaphansi kuka-0.1%, akuthintwa ikhwalithi yamandla okusebenza.
●Kulula ukuyiphatha: ivolumu encane, isisindo esincane.
●Ibhethri elishajekayo langaphakathi, ukuhlola kungaqedwa ngaphandle kokunikezwa kwamandla esizeni.
●Ibanga lokulinganisa isilinganiso: 0.8~10000
●Isivinini sokulinganisa: qedela ukuhlolwa kwezigaba ezintathu ngemizuzu engu-1
●Ukunemba kokulinganisa: ukunemba kwamandla kagesi ohlangothini lwe-HV: 0.05%
ukunemba kwamandla kagesi wohlangothi lwe-LV: 0.1%
ukunemba kwe-engeli yesigaba: 0.1°
ukunemba kwesilinganiso: 0.1% (0.8-3000)
0.2% (3000-10000)
●Isisindo: 3kg.
●Ukunikezwa kwamandla: 220V±10%, 50Hz±1Hz
●Izinga lokushisa: -20℃ ~40℃
●Umswakama olinganiselwe: ≤85%, awujiki