I-GDRB-F Transformer Wining Deformation Tester (SFRA & Impedans Method)
●Ukuthola nokulawula kusetshenziswa i-microprocessor enesivinini esikhulu, edidiyelwe kakhulu.
●Isixhumanisi esibonakalayo se-USB sokuxhumana esisetshenziswa phakathi kwekhompyutha ephathekayo nensimbi.
●Izingxenyekazi zekhompuyutha zamukela ubuchwepheshe bokuskena bedijithali be-DDS obuzinikezele bedijithali (i-USA), obukwazi ukuhlonza ngokunembile amaphutha njengokuphenduka okusontekile, okugobile, ukuguquka, ukutsheka, ukuguquguquka kwe-inter-turn short-circuit kanye ne-inter- phase contact short-circuit.
●Isampula ye-speed dual-channel 16-bit A/D (esivivinyweni senkambu, hambisa isishintshi sompompi, futhi ijika lamagagasi libonisa izinguquko ezisobala).
●I-amplitude yokuphuma kwesignali ilungiswa isofthiwe, futhi inani eliphakeme le-amplitude ngu-± 10V.
●Ikhompyutha izozihlaziya ngokuzenzakalelayo imiphumela yokuhlolwa bese ikhiqiza imibhalo ye-elekthronikhi (iZwi).
●Ithuluzi linezici zokulinganisa ezimbili: ukulinganisa imvamisa yokuskena okuqondile kanye nesilinganiso sokuskena imvamisa yesegimenti, ehambisana nemodi yokulinganisa yamaqembu amabili obuchwepheshe e-China.
●Izici ze-amplitude-frequency zihambisana nezicaciso zobuchwepheshe kazwelonke kumhloli wezimpawu ze-amplitude-frequency.I-X-coordinate (imvamisa) inokukhomba ngomugqa kanye ne-logarithmic indexing, ngakho-ke umsebenzisi angakwazi ukuphrinta ijika nge indexing yomugqa kanye ne-logarithmic indexing.Umsebenzisi angakhetha noma ngokwezidingo zangempela.
●Uhlelo lokuhlaziya idatha oluzenzakalelayo.
Ukuqhathaniswa okuvundlile kokufana okumazombezombe phakathi kwezigaba ezintathu A, B kanye no-C
Imiphumela imi kanje:
① Ukuvumelana okuhle kakhulu
② Ukungaguquguquki okuhle
③ Ukungaguquguquki okungalungile
④ Ukungaguquguquki okubi kakhulu
Ukuqhathaniswa kobude i-AA, BB, CC kubiza idatha yoqobo kanye nedatha yamanje esigabeni esifanayo sokuqhathanisa ukuwohloka kokuphenduka
Imiphumela yokuhlaziya ithi:
① Ukujikajika okujwayelekile
② Ukuguquguquka okuncane
③ Ukuguqulwa okumaphakathi
④ Ukuguqulwa okukhulu
●Idokhumenti ye-elekthronikhi ye-Word ingakhiqizwa ngokuzenzakalela ukuze igcinwe futhi iphrinte.
●Ithuluzi lingahlangabezana ngokugcwele nezidingo zobuchwepheshe ze-DL/T911-2004 ejwayelekile kagesi "Ukuhlaziywa kwempendulo yemvamisa ekuwohlokeni okugoqayo kwama-transformer amandla".
●I-transformer winding deformation tester yakhiwe ingxenye yokulinganisa kanye nengxenye yesofthiwe yokuhlaziya.Ingxenye yokulinganisa ilawulwa i-microcomputer ye-single-chip enesivinini esikhulu, futhi yakhiwe ukukhiqizwa kwesignali nokulinganisa isignali.Ingxenye yokulinganisa isebenzisa isixhumi esibonakalayo se-USB ukuze ixhume nethebhulethi noma ikhompuyutha ephathekayo.
●Enkambweni yokuhlola, ibhasi yokuxhuma kuphela ye-transformer idinga ukususwa, futhi zonke izivivinyo zingaqedwa ngaphandle kokulenga ikhava nokuhlakaza i-transformer.
●Ithuluzi linemisebenzi ehlukahlukene yokulinganisa imvamisa yomugqa wokushanela isistimu yokulinganisa, imvamisa yokuskena yesilinganiso sokushanela imvamisa ifinyelela ku-10MHz, isikhawu sokuskena imvamisa singahlukaniswa sibe ngu-0.25kHz, 0.5kHz kanye no-1kHz, ukuhlinzeka ngokuhlaziywa okwengeziwe kwesiguquli. ukuguquguquka.
●Ithuluzi lihlakaniphe kakhulu, lisebenziseka kalula, futhi linemisebenzi eminingi njengokulungiswa kobubanzi okuzenzakalelayo kanye nokulungiswa kwamasampuli okuzenzakalelayo.
●Isoftware yamukela inkundla yeWindows, iyahambisana neWindows98/2000/winXP/Windows7 system.Nikeza abasebenzisi ngesibonisi esilula nesisebenziseka kalula.
●Nikeza ngokuhlaziywa kokuqhathaniswa kwejika lomlando, ingalayisha ukubonwa kwejika okuningi komlando ngesikhathi esisodwa, ingakhetha ngokukhethekile noma iyiphi ijika yokuhlaziya okuvundlile nokuma mpo.Ifakwe uchwepheshe ohlakaniphile wokuhlaziya kanye nesistimu yokuxilongwa, ingakwazi ukuhlonza ngokuzenzakalelayo isimo se-transformer windings, ilayishe ama-curve angu-6 ngesikhathi esifanayo, futhi ibale ngokuzenzakalelayo imingcele efanele yejika ngalinye, ihlole ngokuzenzakalelayo ukuguquguquka kwama-windings, futhi inikeze isiphetho senkomba yokuxilongwa.
●Umsebenzi wokuphatha isofthiwe onamandla, ucabangela ngokugcwele izidingo zokusetshenziswa kwendawo, futhi ulondoloza ngokuzenzakalelayo imingcele yesimo semvelo ukuze unikeze isisekelo sokuxilongwa kwe-transformer winding deformation.Idatha yokulinganisa ilondolozwa ngokuzenzakalelayo futhi inomsebenzi wokuphrinta umbala, okulungele abasebenzisi ukukhipha imibiko yokuhlola.
●Isoftware inezici ezisobala ezisebenziseka kalula.Iningi lemibandela yokulinganisa yizinto ozikhethela zona.Imingcele enemininingwane ye-transformer ingagcinwa ukuze kusetshenziswe inkomba yokuxilongwa, futhi asikho isidingo sokungena esizeni, futhi umsebenzisi angakwazi ukwengeza futhi alungise imininingwane kamuva, okulula ukuyisebenzisa.
●Isoftware inezinga eliphezulu lobuhlakani.Ngemuva kokuthi amasiginali okokufaka nokuphumayo axhunyiwe futhi nemingcele yesimo isethiwe, yonke imisebenzi yokulinganisa ingaqedwa, futhi ijika le-waveform lomlando lingavulwa esilinganisweni nganoma yisiphi isikhathi ukuze kubhekwe ukuqhathanisa nokukalwa kokuyeka.
●Isikhathi esidingekayo sesilinganiso sesigaba ngasinye singaphansi kwamasekhondi angama-60.Isikhathi esiphelele sokulinganisa ukuwohloka kokuphenduka kwesiguquli samandla esinama-winding aphezulu, aphakathi nendawo naphansi (umthamo nezinga le-voltage alikhawulelwe) singaphansi kwemizuzu eyi-10.
●Lapho ukala i-transformer, abasebenzi bezintambo bangabeka ngokungenasisekelo okokufaka kwesiginali kanye nemikhondo yokuphuma, engenawo umthelela emiphumeleni yokulinganisa.Abasebenzi bezintambo bangahlala ethangini le-transformer ngaphandle kokuthi behle, banciphise umfutho wabasebenzi.
Imodi yokuskena:
1. Ukusatshalaliswa kokuskena ngomugqa
Ibanga lokulinganisa lokuskena: (10Hz) - (10MHz) 40000 iphoyinti lokuskena, ukulungiswa okungu-0.25kHz, 0.5kHz kanye no-1kHz.
2. Isegimenti yokusabalalisa ukulinganisa imvamisa
Shanela ububanzi bokulinganisa imvamisa: (0.5kHz) - (1MHz), amaphuzu wokuskena angu-2000 ;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Eminye imingcele yezobuchwepheshe:
1. Ibanga lokulinganisa i-amplitude: (-120dB) kuya ku-(+20 dB);
2. Ukunemba kwesilinganiso se-amplitude: 1dB;
3. Ukunemba kwefrikhwensi yokushanela: 0.005%;
4. Ukuvimbela okokufaka kwesignali: 1MΩ;
5. Ukuphazamiseka kokuphuma kwesignali: 50Ω;
6. I-amplitude yokukhishwa kwesignali: ± 20V;
7. Izinga lokuphinda ukuhlolwa kwesigaba: 99.9%;
8. Ubukhulu bezinsimbi zokulinganisa (LxWxH): 340X240X210 (mm);
9. Ubukhulu bebhokisi le-aluminium yensimbi (LxWxH): 370X280X260 (mm);Ibhokisi lebhokisi le-aluminium ingxubevange ibhokisi (LxWxH) 420X300X300 (mm);
10. Isisindo sisonke: 10kg;
11. Izinga lokushisa lokusebenza: -10℃~+40℃;
12. Izinga lokushisa lokugcina: -20℃~+70℃;
13. Umswakama ohlobene: <90%, Okungafinyeleli;