I-GDRB-C Power Transformer Wining Deformation Tester
I-Power transformer winding deformation tester (indlela yokuphendula imvamisa) isekelwe ekukalweni kwemingcele yesici se-transformer windings yangaphakathi, yamukela indlela yokuhlaziya imvamisa yephutha yangaphakathi (FRA), ingahlulela ngokunembile amaphutha angaphakathi ama-transformer.
Ngemuva kokuphothulwa kokuklama nokukhiqizwa kwama-transformer, amakhoyili kanye nesakhiwo sangaphakathi kuyaqedwa, ngakho-ke ngekhoyili ye-multi-winding transformer, uma izinga le-voltage kanye nendlela yokuphefumula kufana, imingcele ehambisanayo (Ci, Li) ngayinye. ikhoyili izonqunywa.Ngakho-ke, ukusabela kwezimpawu zemvamisa yekhoyili ngayinye nakho kuzonqunywa, ngakho-ke izilinganiso zefrikhwensi zamakhoyili ahambisanayo ezigaba ezintathu ziyaqhathaniswa.
Ngesikhathi sokuhlolwa kwe-transformer, uma kwenzeka kuba ne-inter-turn, inter-phase short circuit, noma ukufuduka kwekhoyili okuhlobene okubangelwa ukushayisana ngesikhathi sokuthutha, kanye nokuguqulwa kwekhoyili okubangelwa ukungezwani kwamandla kazibuthe ngesikhathi sokusebenza ngaphansi kwezimo ezimfushane nezimo zephutha, imingcele yokusabalalisa. ama-windings e-transformer azoshintsha, okuthi ngaleyo ndlela kube nomthelela futhi kuguqule izici zesizinda samafrikhwensi asekuqaleni, okungukuthi ukuguquka kwempendulo yefrikhwensi ngobukhulu kanye nokuguquguquka kwamaphoyinti efrikhwensi.Isihloli sokuvundisa i-transformer esakhiwe ngokwendlela yokuhlaziya impendulo iyinoveli yemishini ye-NDT yokuthola iphutha langaphakathi le-transformer.Kusebenza ekutholweni kwephutha lesakhiwo sangaphakathi kuma-transformer amandla angu-63kV-500kV.
Umhloli we-Transformer winding deformation ukunquma izinga lezinguquko kuma-winding angaphakathi e-transformer ngokusekelwe enanini loshintsho, ubukhulu kanye nesifunda esithinta ushintsho kanye nokuthambekela kokushintsha kwe-frequency yokuphendula okulinganiswa kusukela ekushintsheni kwempendulo ezizindeni ezihlukene zefrikhwensi yamajika angaphakathi e-transformer. amapharamitha, bese ingakusiza ukuthi unqume ukuthi i-transformer yonakaliswe kakhulu, noma idinga ukulungiswa okukhulu ngokuhambisana nemiphumela yokulinganisa.
Ku-transformer esebenzayo, kungakhathaliseki ukuthi umdwebo wesici sesizinda se-frequency ulondoloziwe, ngokuqhathanisa umehluko phakathi kwe-spectra yesici se-inter-coil ye-transformer enephutha, inganquma izinga lokuhluleka futhi.Yiqiniso, uma ulondoloze imidwebo yesici sokuqala se-transformer windings, kuyoba lula ukunikeza isisekelo esiqondile sezimo zokusebenza, ukuhlaziywa kwe-post-fault kanye nokulungiswa kokugcinwa kwe-transformer.
Umhloli wokuguquguquka ojikajikayo we-Transformer wakhiwa ikhompuyutha ephathekayo nesilawuli esincane esakha isistimu yokulinganisa ukunemba ngesakhiwo esihlangene, ukusebenza okulula, nomsebenzi wokuhlaziya ophelele kakhudlwana, ongasetshenzwa kubhekiselwa kumanuwali weziqondiso noma ngokuqeqeshwa kwesikhashana.
●Ukuthola nokulawula kusetshenziswa i-microprocessor enesivinini esikhulu, edidiyelwe kakhulu.
●Isixhumanisi esibonakalayo se-USB sokuxhumana esisetshenziswa phakathi kwekhompyutha ephathekayo nensimbi.
●Akudingekile ukusebenzisa ikhompyutha ephathwayo emkhakheni wokulinganisa ngenxa yokuhlanganiswa kwekhompuyutha yezimboni kanye nethuluzi lokulinganisa.
●Izingxenyekazi zekhompuyutha zamukela ubuchwepheshe bokuskena bedijithali be-DDS obuzinikezele bedijithali (i-USA), obukwazi ukuhlonza ngokunembile amaphutha njengokuphenduka okusontekile, okugobile, ukuguquka, ukutsheka, ukuguquguquka kwe-inter-turn short-circuit kanye ne-inter- phase contact short-circuit.
●Isampula ye-speed dual-channel 16-bit A/D (esivivinyweni senkambu, hambisa isishintshi sompompi, futhi ijika lamagagasi libonisa izinguquko ezisobala) .
●I-amplitude yokuphuma kwesignali ilungiswa isofthiwe, futhi inani eliphakeme le-amplitude ngu-± 10V.
●Ikhompyutha izozihlaziya ngokuzenzakalelayo imiphumela yokuhlolwa bese ikhiqiza imibhalo ye-elekthronikhi (iZwi).
●Ithuluzi linezici zokulinganisa ezimbili: ukulinganisa imvamisa yokuskena okuqondile kanye nesilinganiso sokuskena imvamisa yengxenye, ehambisana nemodi yokulinganisa yamaqembu amabili obuchwepheshe e-China.
●Izici ze-amplitude-frequency zihambisana nezicaciso zobuchwepheshe kazwelonke kumhloli wezimpawu ze-amplitude-frequency.I-X-coordinate (imvamisa) inokukhomba ngomugqa kanye ne-logarithmic indexing, ngakho-ke umsebenzisi angakwazi ukuphrinta ijika nge indexing yomugqa kanye ne-logarithmic indexing.Umsebenzisi angakhetha noma ngokwezidingo zangempela.
●Uhlelo lokuhlaziya idatha oluzenzakalelayo,
Ukuqhathaniswa okuvundlile kokufana okumazombezombe phakathi kwezigaba ezintathu A, B kanye no-C
Imiphumela imi kanje:
① Ukuvumelana okuhle kakhulu
② Ukungaguquguquki okuhle
③ Ukungaguquguquki okungalungile
④ Ukungaguquguquki okubi kakhulu
Ukuqhathaniswa kobude i-AA, BB, CC kubiza idatha yoqobo kanye nedatha yamanje esigabeni esifanayo sokuqhathanisa ukuwohloka kokuphenduka
Imiphumela yokuhlaziya ithi:
① Ukujikajika okujwayelekile
② Ukuguquguquka okuncane
③ Ukuguqulwa okumaphakathi
④ Ukuguqulwa okukhulu
●Idokhumenti ye-elekthronikhi ye-Word ingakhiqizwa ngokuzenzakalela ukuze igcinwe futhi iphrinte.
●Ithuluzi lingahlangabezana ngokugcwele nezidingo zobuchwepheshe ze-DL/T911-2004 ejwayelekile kagesi "Ukuhlaziywa kwempendulo yemvamisa ekuwohlokeni okugoqayo kwama-transformer amandla".
Imodi yokuskena:
1. Ukusatshalaliswa kokuskena ngomugqa
Ibanga lokulinganisa lokuskena: (10Hz) - (10MHz) 40000 iphoyinti lokuskena, ukulungiswa okungu-0.25kHz, 0.5kHz kanye no-1kHz.
2. Ukusatshalaliswa kokulinganisa imvamisa yesegimenti
Ibanga lokulinganisa imvamisa yokuskena: (0.5kHz) - (1MHz), amaphuzu wokuskena angu-2000 ;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Eminye imingcele yezobuchwepheshe:
Ibanga lokulinganisa i-amplitude | (-120dB) ukuya ku-(+20 dB); |
Ukunemba kokulinganisa kwe-amplitude | 1dB; |
Iskena ukunemba kwefrikhwensi | 0.01%; |
I-impedance yokufaka isignali | 1MΩ; |
Ukuphazamiseka kokuphuma kwesignali | 50Ω; |
I-amplitude yokuphuma kwesignali | ± 20V; |
Izinga lokuphinda ukuhlolwa kwesigaba | 99.9%; |
Ubukhulu bezinsimbi zokulinganisa (L*W*H) | 300*340*120 (mm); |
Ibhokisi le-aluminium yensimbiubukhulu(L*W*H) | 310*400*330 (mm); |
Isisindo sisonke | 10kg; |
Izinga lokushisa lokusebenza | -10℃~+40℃; |
Izinga lokushisa lesitoreji | -20℃~+70℃; |
Umswakama ohlobene | <90%, Ukungafinyeleli; |
Cha. | Igama | Qty. | Iyunithi |
1 | Okuyinhlokoukulawulaiyunithi | 1 | setha |
2 | Ukuhola kokuhlolwa kokuphendula imvamisa | 2 | izingcezu |
3 | I-clamp yokuhlola | 2 | izingcezu |
4 | Ikhebula eliphansi | 4 | izingcezu |
5 | I-Grounding clamp | 2 | izingcezu |
6 | Ikhebula lokuxhumana le-USB | 1 | ucezu |
7 | Ukufakwa Kwesofthiwe Ifomethi ye-VCD ye-CD-ROM | 1 | imiqulu |
8 | Ukufakwa kwesoftware ye-USB disk | 1 | ucezu |
9 | I-Fuse | 3 | izingcezu |
10 | Intambo yamandla ne-adaptha | 1 | ucezu |
11 | Igayidi yomsebenzisi | 1 | ucezu |
12 | Ikhadi lewaranti | 1 | ucezu |
13 | Uhlu lokupakisha | 1 | ucezu |
14 | Umbiko wokuhlolwa kwefekthri | 1 | ucezu |